Aurora Electronics PVI-3600-OUTD-UK-F-W manual

Page 6

Installation and Operator’s Manual

Page 6 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

 

 

 

PVI-3600-OUTD-UK-F-W

This document applies to the above-mentioned inverters, only.

Fig. 1 - Product label information example

The identification plate present on the inverter includes the following data:

1)Manufacturer Part Number

2)Model Number

3)Serial Number

4)Production Week/Year

Image 6
Contents AURORA Important Safety Instructions Revision TableImportant Safety Instructions Useful Information and Safety Standard Foreword AssemblyGeneral Operation Maintenance and ServiceElectrical Connection Save ALL Documents in a Safe PlacePVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Data Transmission and Check Aurora Technical DescriptionInverter Ground Fault Protective Devices Anti-IslandingFurther Protective Devices System Design Package Inspection Package Check List Description Quantity No Choosing Installation Location Minimum clearance requirementsWall mounting diagram Wall MountingPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Connect Aurora to the Dc disconnect switches AuroraPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Available Data Real time dataInternally Logged Data LED Indicators KEYLED on LED blinking LED off Any of the above conditions Installation phase Aurora is disconnected from grid Aurora Under Production Sleep ModeAurora Initialization and Grid Check Ground InsulationMalfunction-Fault Signal RS-485 Address Setting SignalMessages and Error Codes Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Power Line Modem PLM Data transmission to a PCData transmission to Aurora Easy Control Manual address setting Display menùAddress Information Automatic setting Verifying the paralleled input configurationSET in Mode Parallel Measurement Accuracy Data Description UnitData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values Value PVI-3600-OUTD-UK-F-WGrid protection characteristics Output Values DescriptionGeneral characteristics Description Value Power Derating Power Derating due to Ambient TemperaturePower Derating due to Input Voltage