Aurora Electronics PVI-3600-OUTD-UK-F-W manual Error Description

Page 39

Installation and Operator’s Manual

Page 39 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

 

 

 

 

Message

Warning

Error

Description

 

 

Type

Type

 

 

 

 

 

 

 

 

 

Wind Low

W001

//

Input Voltage under threshold

 

 

Input OC

//

E001

Input overcurrent

 

 

Wind Low

W002

//

Wind Energy low

 

 

Input OV

//

E002

Input Overvoltage

 

 

Internal Error

//

E003

SW error

 

 

Bulk OV

//

E004

Bulk overvoltage

 

 

Internal Error

//

E005

Communication Error

 

 

Out OC

//

E006

Output overcurrent

 

 

Internal Error

//

E007

IGBT saturation

 

 

Internal Error

//

E008

Bulk undervoltage

 

 

Internal Error

//

E009

Internal Error

 

 

Grid Fail

W003

//

Grid Fail

 

 

Internal Error

//

E010

Bulk Low

 

 

Internal Error

//

E011

Ramp Fail

 

 

DC/DC Fail

//

E012

DcDc error revealed by inverter

 

 

Wrong Mode

//

E013

Wrong Input setting (Single

 

 

 

 

 

 

instead of dual)

 

 

Over

//

E014

Overtemperature

 

 

Temperature

 

 

 

 

 

 

 

Capacitors Fault

//

E015

Bulk Capacitor Fail

 

 

Inverter Fail

//

E016

Inverter fail revealed by DcDc

 

 

Internal Error

//

E017

Start Timeout

 

 

Ground Fault

//

E018

I leak fail

 

 

Internal Error

//

E019

leak Sensor fail

 

 

Internal Error

//

E020

Self test error 1

 

 

Internal Error

//

E021

Self test error 2

 

 

Internal Error

//

E022

Self test error 4

 

 

Internal Error

//

E023

Dc-Injection Error

 

 

Grid OV

W004

//

Grid overvoltage

 

 

Grid UV

W005

//

Grid undervoltage

 

 

Grid OF

W006

//

Grid overfrequency

 

 

Grid UF

W007

//

Grid underfrequency

 

 

Z Grid HI

W008

//

Z Grid out of range

 

 

Internal Error

//

E024

Internal Error

 

 

-------------------

//

E025

Riso low (log only)

 

 

Internal Error

//

E026

VRef Error

 

 

Internal Error

//

E027

VGrid Measures error

 

 

Internal Error

//

E028

FGrid Measures error

 

 

Internal Error

//

E029

ZGrid Measures error

 

 

Internal Error

//

E030

ILeak Measures error

 

 

Internal Error

//

E031

Wrong V Measure

 

 

Internal Error

//

E032

Wrong I Measure

 

 

Internal Error

//

E033

Undertemperature

 

 

 

 

 

 

 

 

 

Image 39
Contents AURORA Revision Table Important Safety InstructionsImportant Safety Instructions Useful Information and Safety Standard Foreword AssemblyGeneral Save ALL Documents in a Safe Place Maintenance and ServiceElectrical Connection OperationPVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Aurora Technical Description Data Transmission and CheckInverter Ground Fault Protective Devices Anti-IslandingFurther Protective Devices System Design Package Inspection Package Check List Description Quantity No Minimum clearance requirements Choosing Installation LocationWall Mounting Wall mounting diagramPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Aurora Connect Aurora to the Dc disconnect switchesPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Available Data Real time dataInternally Logged Data LED Indicators KEYLED on LED blinking LED off Any of the above conditions Installation phase Aurora is disconnected from grid Ground Insulation Sleep ModeAurora Initialization and Grid Check Aurora Under ProductionMalfunction-Fault Signal RS-485 Address Setting SignalMessages and Error Codes Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Data transmission to a PC Power Line Modem PLMData transmission to Aurora Easy Control Manual address setting Display menùAddress Information Verifying the paralleled input configuration Automatic settingSET in Mode Parallel Data Description Unit Measurement AccuracyData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values PVI-3600-OUTD-UK-F-W ValueOutput Values Description Grid protection characteristicsGeneral characteristics Description Value Power Derating Power Derating due to Ambient TemperaturePower Derating due to Input Voltage