This screen shows the grid frequency and the related status (in range or out of range, see section 9 for further details)

Fgrid

### Hz

In range

 

or

Fgrid ### Hz Out of range!

After AURORA is connected to the grid the display starts showing cyclically the following information screens, each for 5 seconds:

First screen: Type and Part Number

Type ####

Part N° ####

Second screen: Serial Number and Firmware release number

S/N ####

Firmware ####

Third screen: Measuring Resistance isolation and Leakage Isolation

Riso #mOhm

Ileak

Image 41
Contents AURORA Revision Table Important Safety InstructionsImportant Safety Instructions General Useful Information and Safety Standard ForewordAssembly Electrical Connection Maintenance and ServiceOperation Save ALL Documents in a Safe PlacePVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Aurora Technical Description Data Transmission and CheckInverter Further Protective Devices Ground FaultProtective Devices Anti-Islanding System Design Package Inspection Package Check List Description Quantity No Minimum clearance requirements Choosing Installation LocationWall Mounting Wall mounting diagramPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Aurora Connect Aurora to the Dc disconnect switchesPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Internally Logged Data Available DataReal time data LED on LED blinking LED off Any of the above conditions LED IndicatorsKEY Installation phase Aurora is disconnected from grid Aurora Initialization and Grid Check Sleep ModeAurora Under Production Ground InsulationMessages and Error Codes Malfunction-Fault SignalRS-485 Address Setting Signal Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Data transmission to a PC Power Line Modem PLMData transmission to Aurora Easy Control Address Information Manual address settingDisplay menù Verifying the paralleled input configuration Automatic settingSET in Mode Parallel Data Description Unit Measurement AccuracyData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values PVI-3600-OUTD-UK-F-W ValueOutput Values Description Grid protection characteristicsGeneral characteristics Description Value Power Derating due to Input Voltage Power DeratingPower Derating due to Ambient Temperature