All data are available for transmission via the RS-485 link or PLM. In addition, the first two data of the list are displayed on the LCD. The AURORA Communicator software shall be used in order to download the internally stored data.

5.3LED Indicators

On the front panel of the AURORA inverter there are three LEDs, which give status indications:

1.A green LED labeled Power

2.A yellow LED labeled FAULT

3.A red LED labeled GFI (ground fault)

1

2

3

4

Fig.16 LED’s location

KEY:

LED on

LED blinking

LED off

Any of the above conditions

Image 35
Contents AURORA Revision Table Important Safety InstructionsImportant Safety Instructions General Useful Information and Safety Standard ForewordAssembly Save ALL Documents in a Safe Place Maintenance and ServiceElectrical Connection OperationPVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Aurora Technical Description Data Transmission and CheckInverter Further Protective Devices Ground FaultProtective Devices Anti-Islanding System Design Package Inspection Package Check List Description Quantity No Minimum clearance requirements Choosing Installation LocationWall Mounting Wall mounting diagramPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Aurora Connect Aurora to the Dc disconnect switchesPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Internally Logged Data Available DataReal time data LED on LED blinking LED off Any of the above conditions LED IndicatorsKEY Installation phase Aurora is disconnected from grid Ground Insulation Sleep ModeAurora Initialization and Grid Check Aurora Under ProductionMessages and Error Codes Malfunction-Fault SignalRS-485 Address Setting Signal Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Data transmission to a PC Power Line Modem PLMData transmission to Aurora Easy Control Address Information Manual address settingDisplay menù Verifying the paralleled input configuration Automatic settingSET in Mode Parallel Data Description Unit Measurement AccuracyData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values PVI-3600-OUTD-UK-F-W ValueOutput Values Description Grid protection characteristicsGeneral characteristics Description Value Power Derating due to Input Voltage Power DeratingPower Derating due to Ambient Temperature