Aurora Electronics PVI-3600-OUTD-UK-F-W manual System Design, Installation

Page 15

Installation and Operator’s Manual

Page 15 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

 

Control of the internal temperatures to automatically drive the speed of the external cooling fan. This will allow the inverter to deliver the maximum output power for ambient temperatures up +40 ° C .

The AURORA is designed for safe and reliable operation. This is made possible by the use of redundant control circuits.

2.5System Design:

The overall system design of a wind system is critical to successful operation and maximizing energy production.

Step 1:

The first step is determining the wind resource at a location is a site survey and possible wind monitoring.

Step 2:

The second step is purchasing a pre-designed wind system that includes the Aurora Wind inverter with a turbine specific power curve.

Awind turbine model specific power curve is pre-programmed into the Aurora Wind Inverter. The wind power curve is used by the Aurora Wind Maximum power point tracking algorithm to product the maximum amount of available energy.

Step 3:

The third step a proper installation of the entire wind energy system.

3 INSTALLATION

WARNING: The electrical installation of AURORA must be made in accordance with the electrical standards prescribed by the local regulations and the National electrical standards.

Image 15
Contents AURORA Revision Table Important Safety InstructionsImportant Safety Instructions Useful Information and Safety Standard Foreword AssemblyGeneral Save ALL Documents in a Safe Place Maintenance and ServiceElectrical Connection OperationPVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Aurora Technical Description Data Transmission and CheckInverter Ground Fault Protective Devices Anti-IslandingFurther Protective Devices System Design Package Inspection Package Check List Description Quantity No Minimum clearance requirements Choosing Installation LocationWall Mounting Wall mounting diagramPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Aurora Connect Aurora to the Dc disconnect switchesPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Available Data Real time dataInternally Logged Data LED Indicators KEYLED on LED blinking LED off Any of the above conditions Installation phase Aurora is disconnected from grid Ground Insulation Sleep ModeAurora Initialization and Grid Check Aurora Under ProductionMalfunction-Fault Signal RS-485 Address Setting SignalMessages and Error Codes Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Data transmission to a PC Power Line Modem PLMData transmission to Aurora Easy Control Manual address setting Display menùAddress Information Verifying the paralleled input configuration Automatic settingSET in Mode Parallel Data Description Unit Measurement AccuracyData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values PVI-3600-OUTD-UK-F-W ValueOutput Values Description Grid protection characteristicsGeneral characteristics Description Value Power Derating Power Derating due to Ambient TemperaturePower Derating due to Input Voltage