8.4 General characteristics

 

 

 

 

 

 

 

 

 

 

 

Description

 

 

Value

 

 

 

 

 

PVI-3600-OUTD-UK-F-W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum efficiency

 

96%

 

 

 

 

 

 

 

 

 

 

 

 

Internal consumption during stand-by

 

 

< 8 W

 

 

 

 

 

 

 

 

 

 

 

 

Internal consumption during night time

 

 

< 0,30 W

 

 

 

 

 

 

 

 

 

 

 

Operating ambient temperature

 

-25°C to +60°C (-13°F to 140°F)

 

 

 

 

 

 

 

 

 

 

 

 

Enclosure type

 

 

Nema 4X

 

 

 

 

 

 

 

 

 

 

 

Relative Humidity

 

0 – 100 % condensing

 

 

 

 

 

 

 

 

 

 

 

 

Audible Noise

 

 

< 40dBA

 

 

 

 

 

 

 

 

 

 

 

Size (height x width x depth):

 

420 x 310 x 144 mm

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

 

12.5 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 61
Contents AURORA Revision Table Important Safety InstructionsImportant Safety Instructions Assembly Useful Information and Safety Standard ForewordGeneral Electrical Connection Maintenance and ServiceOperation Save ALL Documents in a Safe PlacePVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Aurora Technical Description Data Transmission and CheckInverter Protective Devices Anti-Islanding Ground FaultFurther Protective Devices System Design Package Inspection Package Check List Description Quantity No Minimum clearance requirements Choosing Installation LocationWall Mounting Wall mounting diagramPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Aurora Connect Aurora to the Dc disconnect switchesPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Real time data Available DataInternally Logged Data KEY LED IndicatorsLED on LED blinking LED off Any of the above conditions Installation phase Aurora is disconnected from grid Aurora Initialization and Grid Check Sleep ModeAurora Under Production Ground InsulationRS-485 Address Setting Signal Malfunction-Fault SignalMessages and Error Codes Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Data transmission to a PC Power Line Modem PLMData transmission to Aurora Easy Control Display menù Manual address settingAddress Information Verifying the paralleled input configuration Automatic settingSET in Mode Parallel Data Description Unit Measurement AccuracyData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values PVI-3600-OUTD-UK-F-W ValueOutput Values Description Grid protection characteristicsGeneral characteristics Description Value Power Derating due to Ambient Temperature Power DeratingPower Derating due to Input Voltage