Aurora Electronics PVI-3600-OUTD-UK-F-W manual Multiple units connection

Page 48

Installation and Operator’s Manual

Page 48 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

 

from OFF to ON. The default position of the switch is OFF. Also, each unit must have a different address. See par. 6.3 to change the addresses.

In order for the RS485 communication line to perform the best, Magnetek recommends to connect its PVI-RS232485 adapter before the first unit of the daisy-chain (see fig. 19 for details)

Equivalent devices may also be used for the same purpose, but they have not been tested therefore Magnetek cannot grant the right functionalities.

Please also note that ordinary commercial adapters may need additional impedance termination. Aurora PVI-RS232485 adapter DOES NOT.

The following diagram shows how to connect multiple units on the same RS-485 bus.

RS-485 Adapter

PVI-RS232485

RS-232

RTN

+TR

-TR

1st Unit

RTN

+TR

 

ON OFF

-TR

 

X

 

2nd Unit

RTN

+TR

ON OFF

-TR X

3rd Unit

RTN

+TR

ON OFF

-TR X

Last Unit

RTN

+TR

 

ON OFF

 

 

 

 

-TR

 

X

 

Fig.18 Multiple units connection

Image 48
Contents AURORA Important Safety Instructions Revision TableImportant Safety Instructions Useful Information and Safety Standard Foreword AssemblyGeneral Maintenance and Service Electrical ConnectionOperation Save ALL Documents in a Safe PlacePVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Data Transmission and Check Aurora Technical DescriptionInverter Ground Fault Protective Devices Anti-IslandingFurther Protective Devices System Design Package Inspection Package Check List Description Quantity No Choosing Installation Location Minimum clearance requirementsWall mounting diagram Wall MountingPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Connect Aurora to the Dc disconnect switches AuroraPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Available Data Real time dataInternally Logged Data LED Indicators KEYLED on LED blinking LED off Any of the above conditions Installation phase Aurora is disconnected from grid Sleep Mode Aurora Initialization and Grid CheckAurora Under Production Ground InsulationMalfunction-Fault Signal RS-485 Address Setting SignalMessages and Error Codes Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Power Line Modem PLM Data transmission to a PCData transmission to Aurora Easy Control Manual address setting Display menùAddress Information Automatic setting Verifying the paralleled input configurationSET in Mode Parallel Measurement Accuracy Data Description UnitData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values Value PVI-3600-OUTD-UK-F-WGrid protection characteristics Output Values DescriptionGeneral characteristics Description Value Power Derating Power Derating due to Ambient TemperaturePower Derating due to Input Voltage