3.3Choosing Installation Location
The location for the installation of AURORA should be selected in accordance to the following recommendations:
AURORA should be placed at a suitable height from ground to allow easy reading of the front display and the status LEDs.
Leave enough room around the unit to allow easy installation and maintenance.
Choose a location sheltered from sun radiation and able to provide some ventilation. Avoid locations where air cannot freely circulate around the unit, or directly exposed to the sun.
The mounting location should also allow space for the Wind Interface Box and the Diversion load.
Minimum clearance requirements on the sides easily access the side cover and to obtain the best performance of the unit are as per the following figure:
500 mm (18”)
>100 mm | >300 mm |
(4”) | (12”) |
| 500 mm (18”) |