Aurora Electronics PVI-3600-OUTD-UK-F-W manual Start-Up

Page 31

Installation and Operator’s Manual

Page 31 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

 

 

 

4 START-UP

NOTE: do not lay any object on AURORA during operation.

WARNING: do not touch the heat sink during operation, some parts could be very hot and cause serious burns.

To turn on AURORA by turning ON the AC disconnecting means after allowing the wind turbine to turn.

1)To turn on the AURORA WIND Inverter the Wind Turbine via the Wind Interface Box must supply at least 50 VDC at the AURORA WIND Inverter Input Terminals.

2)When the control power threshold voltage is met the green power LED on the inverter will start to blink.

3)Switch the Ac disconnect to the ON position.

4)AURORA will start operating and the green LED labeled Power on the front panels will start blinking while the grid is checked to make sure that voltage, impedance and frequency parameters are within operating range requirements. The check can last several minutes depending on the conditions of the grid. During the check the LCD display will show a sequence of three screens, indicating:

Remaining time for next connection.

Grid voltage value and status (in or out of range)

Grid frequency value and status (in or out of range)

5)If the grid check is successfully and the input power has remained above the 50 V control power threshold the inverter will connect to the grid.

6)Then the AURORA will export to the grid and the green Power LED will be continuously lit (provided there is enough wind input power to feed power to the grid).

7)If the grid check is not successful the unit repeats the check over and over again until acceptable grid parameters are found. During this procedure the green power LED keeps blinking. Measure the grid voltage and frequency and then verify the grid configuration of the unit.

Image 31
Contents AURORA Revision Table Important Safety InstructionsImportant Safety Instructions Assembly Useful Information and Safety Standard ForewordGeneral Save ALL Documents in a Safe Place Maintenance and ServiceElectrical Connection OperationPVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Aurora Technical Description Data Transmission and CheckInverter Protective Devices Anti-Islanding Ground FaultFurther Protective Devices System Design Package Inspection Package Check List Description Quantity No Minimum clearance requirements Choosing Installation LocationWall Mounting Wall mounting diagramPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Aurora Connect Aurora to the Dc disconnect switchesPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Real time data Available DataInternally Logged Data KEY LED IndicatorsLED on LED blinking LED off Any of the above conditions Installation phase Aurora is disconnected from grid Ground Insulation Sleep ModeAurora Initialization and Grid Check Aurora Under ProductionRS-485 Address Setting Signal Malfunction-Fault SignalMessages and Error Codes Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Data transmission to a PC Power Line Modem PLMData transmission to Aurora Easy Control Display menù Manual address settingAddress Information Verifying the paralleled input configuration Automatic settingSET in Mode Parallel Data Description Unit Measurement AccuracyData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values PVI-3600-OUTD-UK-F-W ValueOutput Values Description Grid protection characteristicsGeneral characteristics Description Value Power Derating due to Ambient Temperature Power DeratingPower Derating due to Input Voltage