Dimplex LI 11MS operating instructions Transport, 3.2Switch Box, 3.3Heat pump controller, English

Page 16
3.2Switch Box

3.2

English

3.2Switch Box

The switch box is located in the heat pump. It can be swung out after removing the lower front cover and loosening the fastening screw located in the upper right-hand corner.

The switch box contains the supply connection terminals as well the power contactors and the soft starter unit.

The power supply cable and control line are installed ready for use.

3.3Heat pump controller

ATTENTION!

Use the heat pump controller included in the scope of supply to operate the air-to-water heat pump.

The heat pump controller is a convenient electronic regulation and control device. It controls and monitors the entire heating system on the basis of the external temperature, including hot water preparation and safety systems.

The customer must install the external temperature sensor, which is included in the scope of supply of the heat pump control- ler together with the necessary fixing accessories.

4 Transport

ATTENTION!

When transporting the heat pump, care must be taken to ensure that it is not tilted more than 45° (in any direction).

Use a wooden pallet for transporting the heat pump to the final in- stallation location. The basic device can be transported with a lift truck, hand truck or by means of 3/4" pipes fed through the holes in the base plate or frame.

The enclosed operating instructions describe the function and use of the heat pump controller.

ATTENTION!

The heat pump and transport pallet are only joined by the packing film.

Before using the transport holes in the frame, it is necessary to remove the lower side panel assemblies. This is done by loosen- ing each of the two screws at the base and then withdrawing the panels by unhooking them from above. Rehang the panels by gently pushing them in an upwards direction.

Be careful not to damage any components when inserting the pipes through the frame.

3.3Heat pump controller 

Manual background

 Manual background

Manual background Manual background 

Opening the cover

Manual background

Manual background



 

Closing the cover

E-4

Image 16
Contents LI 11MS Page Inhaltsverzeichnis 1 Bitte sofort lesen 1.1Wichtige Hinweise1.2Gesetzliche Vorschriften und Richtlinien 1.3Energiesparende Handhabung der Wärmepumpe2Verwendungszweck der Wärmepumpe 3 Lieferumfang2.1Anwendungsbereich 2.2Arbeitsweise4 Transport 3.2Schaltkasten3.3Wärmepumpenregler ACHTUNG5 Aufstellung 6 Montage5.1Allgemein 6.1Allgemein6.3Heizungsseitiger Anschluss 6.4Elektrischer AnschlussFrostschutz Deutsch7 Inbetriebnahme 7.1Allgemein7.2Vorbereitung 7.3Vorgehensweise8 Reinigung / Pflege 9 Störungen / Fehlersuche10 Außerbetriebnahme / Entsorgung 8.1Pflege11 Geräteinformation Deutsch1Typ- und Verkaufsbezeichnung 2Bauform 3 Leistungsangaben12 Garantieurkunde DeutschKundendienstadresse D-10Table of contents 1Please read immediately 1.1Important information1.2Legal Regulations and Directives 1.3Energy-EfficientUse of the Heat Pump2Purpose of the Heat Pump 3 Scope of delivery2.1Application 2.2Operating Principle3.2Switch Box 4 Transport3.3Heat pump controller English5 Installation 6 Installation5.1General Information 5.2Condensed Water Pipe6.3Heating System Connection 6.4Electrical ConnectionAntifreeze frost protection English8Maintenance and Cleaning 7.3Procedure8.1Maintenance 7 Start-up9 Faults and Trouble- shooting 8.2Cleaning the Heating System8.3Cleaning the Air System 10 Decommissioning/ DisposalDimensions, connections and weight 6Complies with the European safety regulations7Additional model features 11 Device InformationTable des matières 1 A lire immédiatement 1.1Importantes informations1.2Dispositions légales et directives 1.3Utilisation économique en2Utilisation de la pompe à chaleur 3 Fourniture2.1Domaine d’utilisation 2.2Fonctionnement4 Transport 3.2Boîtier électrique3.3Régulateur de pompe à chaleur Français5 Choix de l’emplacement 6 Installation5.1Remarques d’ordre général 6.1Remarques d’ordre général6.3Branchement côté installation de chauffage 6.4Branchement électriqueDébit deau de chauffage minimum Protection antigel7 Mise en service 7.1Remarques d’ordre général7.2Préparation 7.3Procédures à suivre10 Mise hors service / mise au rebut 8 Entretien / nettoyage9 Défaillances/recherche de pannes 8.1EntretienDimensions, raccordements et poids 11Informations sur les appareilsFrançais 1Désignation technique et commerciale 2FormeAnhang / Appendix / Annexes A-II Maßbild / Dimension drawing / Schéma cotéAnnexes · Appendix · Anhang Diagramme / Diagrams / Diagrammes Annexes·Appendix A-III3.1Steuerung / Control / Commande Anhang · Appendix · AnnexesA-IV 6WHXHUOHLWXQJPP3.2Last / Load / Charge Anhang · Appendix · Annexes$OOH4XHUVFKQLWWHPP $OOFURVVVHFWLRQVPPOHPPHQSODQXQG%HOHJXQJGHU6WHFNYHUELQGHU LP/XIW DVVHU,QQHQJHUlW/,06LQWKH/,06DLUWRZDWHULQGRRUXQLW GDQVO¶DSSDUHLODLUHDXLQWpULHXU/,06Anhang · Appendix · Annexes 3.4Legende / Legend / LégendeA-VII Anhang · Appendix · Annexes A-VIIIAnhang · Appendix · Annexes A-IXAnhang · Appendix · Annexes Anhang · Appendix · Annexes 4.4Legende / Legend / LégendeA-XI Anhang · Appendix · Annexes A-XIIAnhang · Appendix · Annexes A-XIIISubject to alterations and errors Glen Dimplex Deutschland GmbHIrrtümer und Änderungen vorbehalten Geschäftsbereich Dimplex