Grizzly MODEL G0765 owner manual Power Supply, Availability, Full-Load Current Rating

Page 16

SECTION 2: POWER SUPPLY

Availability

Before installing the machine, consider the avail- ability and proximity of the required power supply circuit. If an existing circuit does not meet the requirements for this machine, a new circuit must be installed. To minimize the risk of electrocution, fire, or equipment damage, installation work and electrical wiring must be done by an electrican or qualified service personnel in accordance with all applicable codes and standards.

Electrocution, fire, or equipment damage may occur if machine is not correctly grounded and connected to the power supply.

Full-Load Current Rating

The full-load current rating is the amperage a machine draws at 100% of the rated output power. On machines with multiple motors, this is the amperage drawn by the largest motor or sum of all motors and electrical devices that might operate at one time during normal operations.

Full-Load Rating

10A

The full-load current is not the maximum amount of amps that the machine will draw. If the machine is overloaded, it will draw additional amps beyond the full-load rating.

If the machine is overloaded for a sufficient length of time, damage, overheating, or fire may result— especially if connected to an undersized circuit. To reduce the risk of these hazards, avoid over- loading the machine during operation and make sure it is connected to a power supply circuit that meets the requirements in the following section.

-14-

Serious injury could occur if you connect the machine to power before completing the setup process. DO NOT connect to power until instructed later in this manual.

110V Circuit Requirements

This machine is prewired to operate on a power supply circuit that has a verified ground and meets the following requirements:

Nominal Voltage

110V, 115V, 120V

Cycle

60 Hz

Phase

Single-Phase

Power Supply Circuit

15 Amps

A power supply circuit includes all electrical equipment between the breaker box or fuse panel in the building and the machine. The power sup- ply circuit used for this machine must be sized to safely handle the full-load current drawn from the machine for an extended period of time. (If this machine is connected to a circuit protected by fuses, use a time delay fuse marked D.)

For your own safety and protection of property, consult an electrician if you are unsure about wiring practices or electrical codes in your area.

Note: The circuit requirements listed in this man- ual apply to a dedicated circuit—where only one machine will be running at a time. If this machine will be connected to a shared circuit where mul- tiple machines will be running at the same time, consult a qualified electrician to ensure that the circuit is properly sized for safe operation.

Model G0765 (Mfd. Since 12/13)

Image 16
Contents Model G0765 14 Benchtop Lathe Page Table of Contents Service Control Panel WiringMachine Description Manual Accuracy IntroductionContact Info Identification Control Panel Controls ComponentsCarriage Tailstock Rear Controls End GearsMachine Data Sheet Tailstock Info Features Safety Safety Instructions for MachineryPage Additional Safety for Metal Lathes Additional Chuck Safety Power Supply AvailabilityFull-Load Current Rating 110V Circuit RequirementsGrounding & Plug Requirements Extension CordsMinimum Gauge Size 14 AWG 50 ftSetup Needed for SetupPreparation UnpackingInventory Installed Components Figure QtyPackaged Components Figures Qty Before cleaning, gather the following CleanupBasic steps for removing rust preventative Site Considerations Assembly Power ConnectionConnecting Power Disconnecting PowerTest Run Disengaged Factory adjustments that should be verified Recommended AdjustmentsSpindle Break-In Operations Operation OverviewInstallation Removal Device Chuck & Faceplate MountingTo install the chuck Chuck InstallationTools Needed Qty Scroll Chuck Clamping Changing Jaw SetTo change the jaw set Faceplate To mount a non-concentric workpiece to the faceplateUsing Quill TailstockTailstock Quill Specs Positioning TailstockInstalling Tooling Offsetting TailstockTo install tooling in the tailstock Removing ToolingAligning Tailstock to Spindle Centerline To offset the tailstockItems Needed Qty To align the tailstock to the spindle centerlinePage Centers Dead CentersMounting Dead Center in Spindle Removing Center from SpindleMounting Center in Tailstock Removing Center from TailstockMounting Workpiece Between Centers To mount a center in the tailstockTo install and use the steady rest Tools Needed for Installation/Removal QtySteady Rest Installing Tool Compound Rest Four-Way Tool PostAligning Cutting Tool with Spindle Centerline Below are two common methodsTo align cutting tool with tailstock center Top ViewManual Feed Spindle SpeedSetting Spindle Speed Range Setting Spindle Direction & SpeedConfiguration Example To set spindle speed to 100 RPMPower Feed Power Feed ControlsSetting Power Feed Rate To set power feed for 0.04 in./revPrimary Threading Configuration Power Feed ConfigurationSecondary Threading Configuration End GearsTo configure end gears for threading 20 TPI End Gear Configuration Example40T 65T Gear 50 T Ge ar 20 TPI Page Threading Headstock Threading ControlsTo set the lathe to thread 20 TPI Feed Direction LeverApron Threading Controls Thread Dial ChartThread Dial Dial Number Thread Dial Accessories D3640-Shop Fox Tool Table PlusCleaning/Protecting MaintenanceSchedule Lubrication Frequency LubricationBall Oilers Bedways Leadscrew & Carriage RackCross Slide & Compound Slide Machine Storage Change Gear BushingTumbler Gears Preparing Lathe for StorageTroubleshooting ServiceSymptom Possible Cause Possible Solution Lathe Operation Backlash Adjustment Leadscrew End-Play AdjustmentCross Slide To remove leadscrew end playGib Adjustment To adjust cross slide and compound slide gibsHalf Nut Adjustment Fuse ReplacementTo adjust half nut To replace fuseBrush Replacement To replace motor brushesTiming Belt Tension Replacement Tensioning Timing BeltReplacing Timing Belt Wiring Wiring Safety InstructionsControl Panel Wiring Machine FrameControl Panel Wiring Photos G0765 wiring overviewMotor/Speed Sensor/ Plug Wiring 110 VACMain Description Description Labels & Cosmetics Front 255 254 256 257 259 258 253 252 261 251 260Threading Charts AppendixWarranty Card CommentsGrizzly INDUSTRIAL, INC BOX BELLINGHAM, WAWarranty & Returns