FUNCTION KEYS
The five keys located to the right of the display are the function keys. They are:
io._o_
_j
E
_p_- Selects the Blade Speed display
NOTE: In order to extend battery life the display will shut off approximately five (5) minutes after the last key was pressed.
USING THE ELECTRONIC INDICATOR SYSTEM
1.Setting the Bevel Angle Reference Point. Whenever the battery is installed or a new zero
point is desired, it is necessary to set the zero reference. Normally the zero reference is set with the blade vertical to the table. When the blade is
in the desired position for the zero point do the following.
a. Press theIONIOFI¢key if display is off.
b. Press the
2. Selecting Blade Tension
n
a. Press the IoF_.IQFkey! if display is off.
b. Press the _ T,. | key. |
c. The digital display will show one of seven tension settings. Turn the tension knob until the correct
| i Indicates correct tension for: | ||
L | Loose - no | tension | |
S | Sanding | Belt | |
.125 | 1/8" | blade | |
.250 | 1/4" | blade | |
.375 | 3/8" | blade | |
.500 | 1/2" | blade | |
E | Overtensioned |
3. Blade Speed
The digital display will read out one of two starting speeds, depending on where the motor belt is positioned on the pulleys. The two starting speeds are 3000 FPM and 1500 FPM. The speed ranges for each starting point are:
3000 | 1500 |
2800 | 1400 |
*2600 | '1300 |
2400 | 1200 |
2200 | 1100 |
2OOO | 1000 |
The band saw motor wilt stall if the blade speed drops two steps* below operating speed,
NOTE: It is important to maintain maximum cutting efficiency by keeping the blade speed as fast as possible. Do not feed the work piece too rapidly, tt will overload the motor and stall the blade,
25