Miller Electric manual Setup and Operation, Safety Equipment, IH/TS Setup Select Power Source

Page 20

SECTION 6 − SETUP AND OPERATION

6-1. Safety Equipment

1

2

Wear the

following during

operation:

 

 

 

 

 

 

1.

Dry, Insulating Gloves

 

 

2.

Safety Glasses With Side

 

 

 

Shields

 

DO NOT wear rings or watches during operation.

sb3.1* 1/94

6-2. IH/TS Setup

6-2-1. Select Power Source

Energize the power source, cooler, and IH/TS. A power source selection will appear in the top right corner of the IH/TS front panel Parameter Display. Press the recessed Power Source Select button on the IH/TS rear panel to toggle through and select the appropriate power source maximum output. This selection will provide the proper out- put scaling in the parameter display screen for the power source that is attached to the IH/TS.

Parameter Display

 

 

 

 

 

 

 

0 . 0

K W P w r

P S 2 5

 

 

0

A m p s

( r m s )

 

 

0

V o l t s

 

( r ms )

 

 

1 2 . 5

K H s F r e q u e n c y

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Source Max Output

OM-203 185 Page 16

Image 20
Contents OM-203 185F ProcessesDescription File Induction HeatingFrom Miller to You Table of Contents Resetting All RAM Variables In The Event Of Display Errors − Safety Precautions − Read Before Using Symbol UsageInduction Heating Hazards Electric Shock can killPrincipal Safety Standards California Proposition 65 WarningsEMF Information About PacemakersLE Chauffage PAR Induction peut provoquer un incendie − Mesures DE Securite Pour LE Chauffage PAR InductionLE Chauffage PAR Induction peut être dangereux DES Organes Mobiles peuvent provoquer des blessures Porteurs de stimulateur cardiaque, restez à distanceEn ce qui concerne les stimulateurs cardiaques − Introduction − Installation SpecificationsIH/TS Installation Specification DescriptionConnecting To Power Source Input 14 Pin Information For Receptacle RC1Rear Connecting 25kW System Cords And CablesFront Connecting 5kW System Cords And Cables FrontRearCooler Such as grinders, drills, lights, etcConnecting External Device − Components and Controls IH/TS Front PanelIH/TS Rear Panel 200.0 Controller− Setup and Operation Safety EquipmentIH/TS Setup Select Power Source Parameter DisplayTime Date Setup − Digital 2-2 Login As EngineerLocale Setup 2-1 Digital Recorder ControlsTime And Date Setup Login As UserGo To Home Screen Channel Cycling On/Off And NotesOperation Controller Display DefinitionsRun List Sub-Menu Definitions NameController Operation Programming The 2408 Controller Program List Terms And DefinitionsSegment Type Definitions Setpoint remains constant for a specified periodExample Pre−heat Profile Example Stress Relief Profile Step to 600 FRamp rate Deg/ hrExample Multi−Step Stress Relief Profile Ramp to 800 F @ 400 /hr Ramp to 1250 FRamp to 800 F Ramp to 600 F Deg/hrProfile Set-Up Worksheet Sets output toStart Recording Batch Recording Using 5100 Digital RecorderBegin Batch recording -3-3-1. Login As User Stop Recording Saving Data To a Disk Recommended After Each BatchDownloading Files From Recorder Network Connection Windows 95, 98, MEChanging IP Address To Connect The IH/TS For Windows Troubleshooting Connection Problems For Windows 95, 98, MERunning a Program To Preheat Or Stress Relief Recovering From An Interruption OP1 SP2Installing Review Software And First Time Setup Review software first time setup screenViewing Data In Review Software Backing Up The DatabaseSelect Transfer Files Running Review SoftwareStart Review software Select Files Single File With Batch Name Select OKSingle File With No Batch Name Select Start TransferMultiple Files With Batch Names Multiple Files With No Batch NamesSelect File Select New Chart Select Add PointScrn14 Select OK to view chart These steps must be done Scrn20 Select OK Comment becomes part of the chart Select Save File name becomes Part of the chart Select File Select Print to print entire profile on oneScrn30 Typical Profile Chart Printout − Configuring Controller and Recorder For each Channel Number Select Channel NumberDate Setup Load FileGo To Home Screen Time SetupLogin As User − Maintenance & Troubleshooting Routine MaintenanceTroubleshooting MonthsBefore 10 degree window is Goto ConF, IA ConF Module 1 Config. See SectionIf display flashes no.io again, or if When touched, but does not Is complete, turn Ihts power off and back on againSee Section Advance to next screenDiagnostic Procedures For IH/TS OM-203 185 5100V Recorder Displays Channel Error Resetting All RAM Variables In The Event Of Display Errors Factory Set Parameters Controller Version NumberPress Page to Press Scroll Version NumberController Edit Parameters Controller Full Parameters Prior To Version Navigation Across Scroll Down Home ListVaries Output ListNavigation Across Configure Parameters Prior To VersionController Controller Full Parameters Effective w/Version OM-203 Navigation Across Scroll Down Home ListConfigure Parameters Effective w/Version Calibration Certification Procedure Type-K Mini ConnectorFluke-714 Thermocouple Calibrator− Electrical Diagrams Circuit Diagram For IH/TS− Parts List Complete Assembly198 Page Page Support ServiceYour distributor also gives To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s