Miller Electric IH, TS manual Time And Date Setup, Login As User, Go To Home Screen

Page 22

NOTE

In general, for those locations that observe DST: DST begins at 2:00 am on the first Sunday in April. DST ends at 2:00 am on the last Sunday in October.

See “http://deil.lang.uiuc.edu/web.pages/holidays/DST.html for exceptions.

8. Touch Apply.

6-2-2-5. Time And Date Setup

1.Touch System.

2.Touch Clock.

3.Adjust time and date, if necessary.

4.Touch Apply.

6-2-2-6. Login As User

1.Touch top left corner (Engineer).

2.Touch pull down next to User.

3.Touch User from pull down list.

6-2-2-7. Go To Home Screen

1.Touch the Menu key in bottom right corner to open Root Menu.

2.Touch Home.

6-2-2-8. Channel Cycling On/Off And Notes

When Trend graphs are displayed, the operator has the option to sequentially display the TC readings for each channel by activating the “Channel Cycling On”option. When channel cycling is off, recorder displays only the selected TC value.

To activate/deactivate “Channel Cycling”:

1.Press the Option key to open options menu.

2.Press channel cycling On to activate cycling or press channel cycling Off to deactivate cycling.

To manually change which TC is displayed, press the TC field to advance to the next TC reading.

Notes can be added to a chart on the recorder while viewing a trend screen.

Press the “Option Menu” button. Press “Note”.

Press the field next to “User Note” and enter notes using keypad.

Press “OK”.

Press “OK”.

The note is added to the chart.

The note can be viewed on the bottom of the screen or in the history screen.

Press the Option key, press “Enter History”.

To exit, press the Option key, then press “Exit History”.

scrn34

OM-203 185 Page 18

Image 22
Contents Description OM-203 185FProcesses File Induction HeatingFrom Miller to You Table of Contents Resetting All RAM Variables In The Event Of Display Errors Induction Heating Hazards − Safety Precautions − Read Before UsingSymbol Usage Electric Shock can killPrincipal Safety Standards California Proposition 65 WarningsEMF Information About PacemakersLE Chauffage PAR Induction peut être dangereux − Mesures DE Securite Pour LE Chauffage PAR InductionLE Chauffage PAR Induction peut provoquer un incendie DES Organes Mobiles peuvent provoquer des blessures Porteurs de stimulateur cardiaque, restez à distanceEn ce qui concerne les stimulateurs cardiaques − Introduction IH/TS Installation − InstallationSpecifications Specification DescriptionConnecting To Power Source Input 14 Pin Information For Receptacle RC1Front Connecting 25kW System Cords And CablesRear Cooler Connecting 5kW System Cords And CablesFrontRear Such as grinders, drills, lights, etcConnecting External Device − Components and Controls IH/TS Front PanelIH/TS Rear Panel 200.0 ControllerIH/TS Setup Select Power Source − Setup and OperationSafety Equipment Parameter DisplayLocale Setup Time Date Setup − Digital2-2 Login As Engineer 2-1 Digital Recorder ControlsGo To Home Screen Time And Date SetupLogin As User Channel Cycling On/Off And NotesRun List Sub-Menu Definitions OperationController Display Definitions NameController Operation Segment Type Definitions Programming The 2408 ControllerProgram List Terms And Definitions Setpoint remains constant for a specified periodExample Pre−heat Profile Ramp rate Example Stress Relief ProfileStep to 600 F Deg/ hrRamp to 800 F Ramp to 600 F Example Multi−Step Stress Relief ProfileRamp to 800 F @ 400 /hr Ramp to 1250 F Deg/hrProfile Set-Up Worksheet Sets output toBegin Batch recording -3-3-1. Login As User Batch Recording Using 5100 Digital RecorderStart Recording Stop Recording Saving Data To a Disk Recommended After Each BatchChanging IP Address To Connect The IH/TS For Windows Network Connection Windows 95, 98, MEDownloading Files From Recorder Troubleshooting Connection Problems For Windows 95, 98, MERunning a Program To Preheat Or Stress Relief Recovering From An Interruption OP1 SP2Viewing Data In Review Software Installing Review Software And First Time SetupReview software first time setup screen Backing Up The DatabaseStart Review software Running Review SoftwareSelect Transfer Files Select Files Single File With Batch Name Select OKSingle File With No Batch Name Select Start TransferMultiple Files With Batch Names Multiple Files With No Batch NamesSelect File Select New Chart Select Add PointScrn14 Select OK to view chart These steps must be done Scrn20 Select OK Comment becomes part of the chart Select Save File name becomes Part of the chart Select File Select Print to print entire profile on oneScrn30 Typical Profile Chart Printout − Configuring Controller and Recorder For each Channel Number Select Channel NumberDate Setup Load FileLogin As User Time SetupGo To Home Screen Troubleshooting − Maintenance & TroubleshootingRoutine Maintenance MonthsIf display flashes no.io again, or if Goto ConF, IA ConF Module 1 Config. See SectionBefore 10 degree window is See Section When touched, but does notIs complete, turn Ihts power off and back on again Advance to next screenDiagnostic Procedures For IH/TS OM-203 185 5100V Recorder Displays Channel Error Resetting All RAM Variables In The Event Of Display Errors Press Page to Press Scroll Factory Set ParametersController Version Number Version NumberController Edit Parameters Varies Controller Full Parameters Prior To VersionNavigation Across Scroll Down Home List Output ListController Configure Parameters Prior To VersionNavigation Across Controller Full Parameters Effective w/Version OM-203 Navigation Across Scroll Down Home ListConfigure Parameters Effective w/Version Fluke-714 Thermocouple Calibration Certification ProcedureType-K Mini Connector Calibrator− Electrical Diagrams Circuit Diagram For IH/TS− Parts List Complete Assembly198 Page Page Your distributor also gives ServiceSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s