Miller Electric IH, TS manual See Section, When touched, but does not, Advance to next screen

Page 58

 

Trouble

 

Remedy

 

 

2408 Temperature Controller reads

See Section 8-3I.

greater than 5° F different than

 

Channel 1 on 5100V Recorder.

 

 

 

 

 

2408

Temperature

Controller

Check and secure connections to the workpiece.

readings fluctuate

rather

than

 

remain stable.

 

 

 

 

 

 

 

5100V

Recorder screen

blinks

Screen calibration needs adjusting. Turn off IHTS power switch. Turn on IHTS power switch while touching

when touched, but does not

screen, and continue to touch screen (about 45 seconds) until configuration display appears on the screen.

advance to next screen.

 

Press “Touch Cal” or wait a few minutes for the Touch Cal display to appear on the screen. Use a pointed object

 

 

 

 

(be careful not to damage screen), and touch each set of cross hairs to calibrate screen. When calibration

 

 

 

 

is complete, turn IHTS power off and back on again.

 

 

5100V Recorder does not recognize

Floppy disks do not work well in ambient temperatures greater than 104° F (40° C).

floppy disk.

 

 

 

 

 

Clean floppy drive with a disk drive cleaner (available from a local computer reseller).

 

 

 

 

 

 

 

 

 

OM-203 185 Page 54

Image 58
Contents Description OM-203 185FProcesses File Induction HeatingFrom Miller to You Table of Contents Resetting All RAM Variables In The Event Of Display Errors Induction Heating Hazards − Safety Precautions − Read Before UsingSymbol Usage Electric Shock can killPrincipal Safety Standards California Proposition 65 WarningsEMF Information About PacemakersLE Chauffage PAR Induction peut être dangereux − Mesures DE Securite Pour LE Chauffage PAR InductionLE Chauffage PAR Induction peut provoquer un incendie DES Organes Mobiles peuvent provoquer des blessures Porteurs de stimulateur cardiaque, restez à distanceEn ce qui concerne les stimulateurs cardiaques − Introduction IH/TS Installation − InstallationSpecifications Specification DescriptionConnecting To Power Source Input 14 Pin Information For Receptacle RC1Front Connecting 25kW System Cords And CablesRear Cooler Connecting 5kW System Cords And CablesFrontRear Such as grinders, drills, lights, etcConnecting External Device − Components and Controls IH/TS Front PanelIH/TS Rear Panel 200.0 ControllerIH/TS Setup Select Power Source − Setup and OperationSafety Equipment Parameter DisplayLocale Setup Time Date Setup − Digital2-2 Login As Engineer 2-1 Digital Recorder ControlsGo To Home Screen Time And Date SetupLogin As User Channel Cycling On/Off And NotesRun List Sub-Menu Definitions OperationController Display Definitions NameController Operation Segment Type Definitions Programming The 2408 ControllerProgram List Terms And Definitions Setpoint remains constant for a specified periodExample Pre−heat Profile Ramp rate Example Stress Relief ProfileStep to 600 F Deg/ hrRamp to 800 F Ramp to 600 F Example Multi−Step Stress Relief ProfileRamp to 800 F @ 400 /hr Ramp to 1250 F Deg/hrProfile Set-Up Worksheet Sets output toBegin Batch recording -3-3-1. Login As User Batch Recording Using 5100 Digital RecorderStart Recording Stop Recording Saving Data To a Disk Recommended After Each BatchChanging IP Address To Connect The IH/TS For Windows Network Connection Windows 95, 98, MEDownloading Files From Recorder Troubleshooting Connection Problems For Windows 95, 98, MERunning a Program To Preheat Or Stress Relief Recovering From An Interruption OP1 SP2Viewing Data In Review Software Installing Review Software And First Time SetupReview software first time setup screen Backing Up The DatabaseStart Review software Running Review SoftwareSelect Transfer Files Select Files Single File With Batch Name Select OKSingle File With No Batch Name Select Start TransferMultiple Files With Batch Names Multiple Files With No Batch NamesSelect File Select New Chart Select Add PointScrn14 Select OK to view chart These steps must be done Scrn20 Select OK Comment becomes part of the chart Select Save File name becomes Part of the chart Select File Select Print to print entire profile on oneScrn30 Typical Profile Chart Printout − Configuring Controller and Recorder For each Channel Number Select Channel NumberDate Setup Load FileLogin As User Time SetupGo To Home Screen Troubleshooting − Maintenance & TroubleshootingRoutine Maintenance MonthsIf display flashes no.io again, or if Goto ConF, IA ConF Module 1 Config. See SectionBefore 10 degree window is See Section When touched, but does notIs complete, turn Ihts power off and back on again Advance to next screenDiagnostic Procedures For IH/TS OM-203 185 5100V Recorder Displays Channel Error Resetting All RAM Variables In The Event Of Display Errors Press Page to Press Scroll Factory Set ParametersController Version Number Version NumberController Edit Parameters Varies Controller Full Parameters Prior To VersionNavigation Across Scroll Down Home List Output ListController Configure Parameters Prior To VersionNavigation Across Controller Full Parameters Effective w/Version OM-203 Navigation Across Scroll Down Home ListConfigure Parameters Effective w/Version Fluke-714 Thermocouple Calibration Certification ProcedureType-K Mini Connector Calibrator− Electrical Diagrams Circuit Diagram For IH/TS− Parts List Complete Assembly198 Page Page Your distributor also gives ServiceSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s