Miller Electric IH, TS manual 198

Page 72

Dia.

Part

Description

Quantity

Mkgs.

No.

 

 

 

Figure 10-1. Complete Assembly (Continued)

 

 

 

 

 

. . . . . . . 22

. . . . . 198 893

. . RECEPTACLE, thermocouple

. . . 6

. . . . . . . 23

. . . . . 209 948

. . BRACKET, mtg receptacle RJ45

. . . 2

. . . . . . . 24

. . . . . 175 282

. . COVER, receptacle weatherproof duplex rcpt

. . . 1

. . . . . . . 25

. . . . . 203 975

. . CAPACITOR ASSY

. . . 6

. . . . . . . 26

. . . . . 198 885

. . CABLE, interconnecting

. . . 1

. . . . . . . 27

. . . . . 204 702

. . CORE, toroidal

. . . 1

. . . . . . . 28

. . . . . 204 703

. . CORE, toroidal

. . . 1

. . . . . . . 29

. . . . . 203 264

. . NAMEPLATE,rear w/o recorder

. . . 1

. . . . . . . 29

. . . . . 204 367

. . NAMEPLATE, rear w/recorder

. . . 1

. . . . . . . 30

. . . . . 152 492

. . RCPT W/PINS

. . . 1

. . . . . . . 31

. . . . . 204 227

. . BRACKET, mtg IH/TS

. . . 1

. . . . . . . 32

. . . . . 204 040

. . MOUNT, nprn 100mm recorder 55 durometer

. . . 1

. . . . . . . 33

. . . . . 214 532

. . CABLE ASSY, interconnecting RJ45

. . . 2

. . . . . . . 34

. . . . . 194 067

. . CASE SECTION, front/bottom/rear

. . . 1

. . . . . . . 35

. . . . . 202 602

. . SWITCH, flow w/fittings

. . . 1

. . . . . . . 36

. . . . . 194 068

. . PANEL, front

. . . 1

. . . . . . . 37

. . . . . 194 920

. . RECORDER, temperature, digital

. . . 1

. . . . . . . 38

. . . . . 212 719

. . KIT, switch replacement for 203 137 (including)

. . . 1

. . . . . . . . . . .

. . . . .

203 137

. . . . SWITCH, pb mc DPST NC/NO 1A 115VAC red

. . . 1

. . . . . . . . . . .

. . . .

*210 369

. . . . BOOT, switch pushbutton

. . . 1

. . . . . . . 39

. . . . . 212 718

. . KIT, switch replacement for 203 136 (including)

. . . 1

. . . . . . . . . . .

. . . . .

203 136

. . . . SWITCH, pb mc nc SPST 1A 115VAC black

. . . 1

. . . . . . . . . . .

. . . .

*210 369

. . . . BOOT, switch pushbutton

. . . 1

. . . . . . . 40

. . . . . 212 717

. . KIT, switch replacement for 203 135 (including)

. . . 1

. . . . . . . . . . .

. . . . .

203 135

. . . . SWITCH, pb mc nc SPST 1A 115VAC green

. . . 1

. . . . . . . . . . .

. . . .

*210 369

. . . . BOOT, switch pushbutton

. . . 1

. . . . . . . 41

. . . . . 027 631

. . HOUSING, light

. . . 1

. . . . . . . . . . .

. . . . .

027 629

. . BULB, incand

. . . 1

. . . . . . . . . . .

. . . . .

176 246

. . LENS, light

. . . 1

. . . . . . . 42

. . . . . 197 062

. . LED, blue

. . . 1

. . . . . . . 43

. . . . . 202 200

. . TEMPERATURE CONTROLLER

. . . 1

. . . . . . . . . . .

. . . . .

192 457

. . CORD, power

. . . 1

+When ordering a component originally displaying a precautionary label, the label should also be ordered.

*If replacing a boot only onto an existing switch, apply a silicone spray on both boot and switch to prevent moisture buildup inside boot and ease installation.

To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.

OM-203 185 Page 68

Image 72
Contents OM-203 185F ProcessesDescription File Induction HeatingFrom Miller to You Table of Contents Resetting All RAM Variables In The Event Of Display Errors − Safety Precautions − Read Before Using Symbol UsageInduction Heating Hazards Electric Shock can killPrincipal Safety Standards California Proposition 65 WarningsEMF Information About Pacemakers− Mesures DE Securite Pour LE Chauffage PAR Induction LE Chauffage PAR Induction peut être dangereuxLE Chauffage PAR Induction peut provoquer un incendie DES Organes Mobiles peuvent provoquer des blessures Porteurs de stimulateur cardiaque, restez à distanceEn ce qui concerne les stimulateurs cardiaques − Introduction − Installation SpecificationsIH/TS Installation Specification DescriptionConnecting To Power Source Input 14 Pin Information For Receptacle RC1Connecting 25kW System Cords And Cables FrontRear Connecting 5kW System Cords And Cables FrontRearCooler Such as grinders, drills, lights, etcConnecting External Device − Components and Controls IH/TS Front PanelIH/TS Rear Panel 200.0 Controller− Setup and Operation Safety EquipmentIH/TS Setup Select Power Source Parameter DisplayTime Date Setup − Digital 2-2 Login As EngineerLocale Setup 2-1 Digital Recorder ControlsTime And Date Setup Login As UserGo To Home Screen Channel Cycling On/Off And NotesOperation Controller Display DefinitionsRun List Sub-Menu Definitions NameController Operation Programming The 2408 Controller Program List Terms And DefinitionsSegment Type Definitions Setpoint remains constant for a specified periodExample Pre−heat Profile Example Stress Relief Profile Step to 600 FRamp rate Deg/ hrExample Multi−Step Stress Relief Profile Ramp to 800 F @ 400 /hr Ramp to 1250 FRamp to 800 F Ramp to 600 F Deg/hrProfile Set-Up Worksheet Sets output toBatch Recording Using 5100 Digital Recorder Begin Batch recording -3-3-1. Login As UserStart Recording Stop Recording Saving Data To a Disk Recommended After Each BatchNetwork Connection Windows 95, 98, ME Changing IP Address To Connect The IH/TS For WindowsDownloading Files From Recorder Troubleshooting Connection Problems For Windows 95, 98, MERunning a Program To Preheat Or Stress Relief Recovering From An Interruption OP1 SP2Installing Review Software And First Time Setup Review software first time setup screenViewing Data In Review Software Backing Up The DatabaseRunning Review Software Start Review softwareSelect Transfer Files Select Files Single File With Batch Name Select OKSingle File With No Batch Name Select Start TransferMultiple Files With Batch Names Multiple Files With No Batch NamesSelect File Select New Chart Select Add PointScrn14 Select OK to view chart These steps must be done Scrn20 Select OK Comment becomes part of the chart Select Save File name becomes Part of the chart Select File Select Print to print entire profile on oneScrn30 Typical Profile Chart Printout − Configuring Controller and Recorder For each Channel Number Select Channel NumberDate Setup Load FileTime Setup Login As UserGo To Home Screen − Maintenance & Troubleshooting Routine MaintenanceTroubleshooting MonthsGoto ConF, IA ConF Module 1 Config. See Section If display flashes no.io again, or ifBefore 10 degree window is When touched, but does not Is complete, turn Ihts power off and back on againSee Section Advance to next screenDiagnostic Procedures For IH/TS OM-203 185 5100V Recorder Displays Channel Error Resetting All RAM Variables In The Event Of Display Errors Factory Set Parameters Controller Version NumberPress Page to Press Scroll Version NumberController Edit Parameters Controller Full Parameters Prior To Version Navigation Across Scroll Down Home ListVaries Output ListConfigure Parameters Prior To Version ControllerNavigation Across Controller Full Parameters Effective w/Version OM-203 Navigation Across Scroll Down Home ListConfigure Parameters Effective w/Version Calibration Certification Procedure Type-K Mini ConnectorFluke-714 Thermocouple Calibrator− Electrical Diagrams Circuit Diagram For IH/TS− Parts List Complete Assembly198 Page Page Service Your distributor also givesSupport To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s