SECTION 6 − SETTING SEQUENCE PARAMETERS
6-1. Sequence Parameters In A Program
. See Menu Guide for detailed programming steps.
Trim is arc length. If set to zero, arc length is short. If set to 99, arc length is long.
If time is set to zero in Weld sequence, welding continues until gun trigger is released.
If time is set to zero in any timed sequence except Weld, the sequence is skipped.
|
|
| Trim | Volts | Inductance | IPM | Seconds | |
|
|
|
|
| ||||
1. | Weld | Pulse | X |
|
| X | ||
|
|
|
|
|
|
|
| |
|
| MIG |
| X | X | X |
|
|
|
|
|
|
|
|
|
|
|
2. | Crater | Pulse | X |
|
| X | ||
|
|
|
|
|
|
|
| |
|
| MIG |
| X |
| X |
|
|
|
|
|
|
|
|
|
|
|
3. | Burnback | Pulse |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| MIG |
| X |
|
|
|
|
|
|
|
|
|
|
|
| |
4. & 5. Postflow/ |
|
|
|
|
|
| ||
Preflow |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
6. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
6. | Start | Pulse | X |
|
| X | ||
|
|
|
|
|
|
|
| |
|
| MIG |
| X |
| X |
|
|
|
|
|
|
|
|
|
|
|
X = Setting available.
Wire Speed | WFS | Weld WFS |
|
| Start |
Preflow | Time | |
Time |
| |
|
|
Preflow | Weld | |
| Strike |
|
Trigger |
|
|
Pressed |
|
|
Weld Time
| Crater |
WFS | Time |
Burnback | |
Crater | Time |
Postflow | |
| Time |
Time
| Burnback | Sequence |
Crater | Postflow | |
|
| End |
Trigger |
|
|
Released |
|
|