9-2. System Setup Display Parameters
Note | See Menu Guide for detailed programming steps. |
|
|
DISPLAY SETTING | NOTES |
|
|
>System | Select the process the welding power source is able to do. |
|
|
>Model | For the Invision 456 and XMT 304 selections, pulse data and welding power source minimum and maximum voltage |
| values are automatically loaded in. For the “Other” selection, welding power source minimum and maximum voltage |
| and amperage values must be entered. Pulse data defaults to Invision 456 values. |
|
|
>Access♦ | When on, restricts use of setup screens. |
|
|
>Mig Type | Default is Off. Set to On only for older CV welding power source without voltage feedback at |
|
|
>Voltage | Default is |
| length). |
|
|
>Arc Start* | Use Hot Start only with Inverter Model welding power source and large diameter wires. The arc starts in CV and |
| switches to CC. |
|
|
>Dual Schedule | See Section |
|
|
>Trigger | When on, trigger can be used to switch between programs that have at least 0.2 seconds of preflow time programmed. |
|
|
>Remote | When on, an optional dual schedule switch with a “y” trigger cable adapter cord can be used to change Volts or Trim, |
| IPM, SharpArc, or Prg depending on where the front panel display > is. |
|
|
>Arc Time | Displays accumulated arc time and cycles. |
|
|
>Wire Feed | Choose to display inches per minute or meters per minute and motor type, but installed motor must match selection. |
|
|
>Memory | No Reset: allows operator to exit memory reset parameter without resetting any data. |
| Program Reset: unit defaults to original factory setting for the last active program. Setup information does not change. |
| If setup card is in card slot, program will be loaded from card. |
| System Reset: unit defaults to original factory settings for all programs and setup excluding System and Arc Time. If |
| setup card is in card slot, program will be loaded from card. |
| Total Reset: unit defaults to original factory settings for all programs and setup including System and Arc Time. If setup |
| card is in card slot, program will be loaded from card. |
|
|
>Shutdown | When on, the system immediately shuts down if no arc voltage is sensed. When off, wire feeds even if no arc voltage |
| is sensed. |
|
|
>Gas Flow♦♦ | Setting must be Meter Off if option is not installed. |
|
|
>Ramps | Turns start and crater ramping On or Off. When On, output power is tapered from start to weld and from weld to crater. |
|
|
>Software | Know this when talking with service personnel. |
|
|
♦Can be used only when optional data card is inserted.
* Selection does not appear on display when MIG Only is System choice.
♦♦Must remain set to Meter Off if option is not installed to prevent system error.