8-5. Security
.The security feature works only when a data card is inserted.
|
|
|
| 1 | |
| Press |
|
|
| |
| Mode |
|
|
| |
| Select | S eq u e n c e | > P r o g | 1 | |
Turn | 5 Times | ||||
D ua l S c h d | L oc k | O f f | |||
Unit |
| ||||
| C a r d |
|
| ||
On |
|
|
| ||
|
| > S ec u r i t y |
|
| |
|
|
|
| Side Panel | |
|
|
|
| Parameter | |
4 |
|
| 3 | Select | |
|
|
| |||
|
|
|
|
The security feature allows a mini- mum and maximum range limit to be defined for Trim, inches per min- ute (IPM), and ShpArc (see Section 12).
When the security lock is Off, the full range of values is available for each parameter.
When the security lock is On, the range of values available for each parameter is the defined value plus or minus the defined range.
2 | For example, if the IPM value is de- | ||
fined as 125, and the range is de- | |||
| |||
| fined as 50, the actual range of | ||
| available IPM is 75 to 175 IPM (125 | ||
| minus 50, and 125 plus 50). | ||
| 1 | Card Display | |
| 2 | Moving Line |
P r o g | 1 |
L o c k | O n |
>T r i m | 5 0 |
R a n g e | 0 |
Increase/ | Side Panel |
Parameter | |
Decrease | Select |
P r o g | 1 |
>L o c k | O n |
T r i m | 5 0 |
R a n g e | 0 |
Increase/
Decrease
P r o g | 1 |
>L o c k | O f f |
|
|
Moving line is under value that can | |
be | changed. Change program |
number to access desired program. | |
3 | Lock On/Off |
Toggles security feature On or Off. | |
Definable values are displayed | |
when Lock On is selected. Use side | |
panel controls to change values. | |
4 | Trim And Range Display |
5 | IPM And Range Display |
P r o g | 1 |
| L o c k | O n |
L o c k | O n |
| T r i m | 5 5 |
>T r i m | 5 5 |
| >R a n g e | 0 |
R a n g e | 0 |
| I P M | 2 0 0 |
|
|
|
|
|
Side Panel | Increase/ |
Parameter | Decrease |
Select |
|
5 |
|
L o c k | O n |
|
T r i m | 5 5 |
|
>R a n g e | 1 0 |
|
I P M | 2 0 0 |
|
|
|
|
| Side Panel | |
| Parameter | |
| Select |
6 ShpArc And Range Display |
Definable Values (Standard |
Motor): |
Trim: 0−99 Range: 0−99 |
IPM: 50−780 Range: 0−780 |
ShpArc : 0−20 Range: 0−20 |
In the example displays, the |
operator could change the value of |
Trim to 55 and its Range to ±10. |
T r i m | 5 5 | T r i m | 5 5 | |
R a n g e | 1 0 | |||
R a n g e | 1 0 | |||
> I P M | 2 2 5 | |||
I P M | 2 2 5 | |||
R a n g e | 0 | |||
>R a n g e | 0 | |||
|
| |||
|
| Side Panel | Increase/ | |
Increase/ |
| Parameter | Decrease | |
| Select |
| ||
Decrease |
|
| ||
|
|
| ||
|
| 6 |
|
T r i m | 5 5 |
R a n g e | 1 0 |
> I P M | 2 0 0 |
R a n g e | 0 |
|
|
Also, the operator could change the |
value of IPM to 225 and its Range to |
±100 IPM from programmed |
values. If the range settings are left |
at 0, the operator cannot change |
values from those programmed. |
T r i m | 5 5 |
| I P M | 2 2 5 |
| >P r o g | 1 |
R a n g e | 1 0 |
| R a n g e | 1 0 |
| L o c k | O n |
I P M | 2 2 5 |
| >S h p A r c | 0 |
| T r i m | 5 5 |
>R a n g e 1 0 0 |
| R a n g e | 3 |
| R a n g e | 1 0 | |
|
|
|
|
|
|
|
|
Side Panel | Side Panel |
Parameter | Parameter |
Select | Select |