Hitachi DH 40FA manual HOW to Replace Grease, Maintenance and Inspection

Page 9

English

(3)When the hole depth reaches approximately 5 mm, the hole position can be determined. Then remove the center pin and guide plate from the core bit and continue the hole drilling job.

CAUTION

When removing the center pin and guide plate,

always disconnect the plug from the receptacle.

3. How to dismount the core bit

By holding the drill (with the core bit inserted) in an upward position, drive the drill to repeat hammering operation two or three times, whereby the screw is loosened and the drill becomes ready for disassembly. (Fig. 16)

Remove the core bit shank from the drill, hold the core bit with one hand, and strongly strike the head of the spline portion of the core bit shank with a manual hammer two or three times, whereby the round head screw is loosened and the drill is ready for disassembly. (Fig. 17)

HOW TO REPLACE GREASE

This machine is of full air-tight construction to protect against dust and to prevent lubricant leakage. Therefore, the machine can be used without lubrication for long periods. Replace the grease as described below.

1.Grease replacement period

After purchase, replace grease after every 6 months of usage. Ask for grease replacement at the nearest Hitachi Authorized Service Center. Proceed for replacement of grease.

2.Grease replenishment

CAUTION

Before replenishing the grease, turn the power off

and pull out the power plug.

(1)Remove the crank case cover and wipe off the grease inside. (Fig. 18)

(2)Supply 20g of Hitachi Electric Hammer Grease A (Standard accessory, contained in tube) to the crank case.

As the tube contain 30g of grease, supply 2/3 of the contained grease.

(3)After replenishing the grease, install the crank case cover securely.

NOTE

The Hitachi Electric Hammer Grease A is of the low viscosity type. If necessary purchase from a Hitachi Authorized Service Center.

MAINTENANCE AND INSPECTION

1.Inspecting the tool

Since use of a dull tool will degrade efficiency and cause possible motor malfunction, sharpen or replace the tool as soon as abrasion is noted.

2.Inspecting the mounting screws:

Regularly inspect all mounting screws and ensure that they are properly tightened. Should any of the screws be loose, retighten them immediately. Failure to do so could result in serious hazard.

3.Maintenance of the motor

The motor unit winding is the very “heart” of the power tool. Exercise due care to ensure the winding does not become damaged and/or wet with oil or water.

4.Inspecting the carbon brushes (Fig. 19)

The Motor employs carbon brushes which are consumable parts. When they become worn to or near the “wear limit”, it could result in motor trouble. When an auto-stop carbon brush is equipped, the motor will stop automatically. At that time, replace both carbon brushes with new ones which have the same carbon brush Numbers shown in the figure. In addition, always keep carbon brushes clean and ensure that they slide freely within the brush holders.

5.Replacing carbon brushes

Loosen the two set screws and remove the tail cover. Remove the brush caps and carbon brushes. After replacing the carbon brushes, tighten the brush caps securely and install the tail cover with securely tightening two set screws.

NOTE

Due HITACHI’s continuing program of research and development, the specifications herein are subject to change without prior notice.

IMPORTANT

Correct connection of the plug

The wires of the main lead are coloured in accordance

with the following

code:

Blue:

— Neutral

Brown:

— Live

As the colours of the wires in the main lead of this tool may not correspond with the coloured markings identifying the terminals in your plug proceed as follows:

The wire coloured blue must be connected to the terminal marked with the letter N or coloured black. The wire coloured brown must be connected to the terminal marked with the letter L or coloured red. Neither core must be connected to the each terminal.

NOTE

This requirement is provided according to BRITISH STANDARD 2769: 1984.

Therefore, the letter code and colour code may not be applicable to other markets except The United Kingdom.

Information concerning airborne noise and vibration The measured values were determined according to EN50144.

The typical A-weighted sound pressure level: 89 dB (A)

The typical A-weighted sound power level: 102 dB (A) Wear ear protection.

The typical weighted root mean square acceleration value: 10 m/s2

8

Image 9
Contents DH 40FA 6 a 12Z Page Page General Operational Precautions Precautions on Using Rotary HammerEnglish Standard Accessories SpecificationsOptional Accessories sold separately ApplicationsHOW to Handle a Core BIT HOW to USE the Rotary HammerMaintenance and Inspection HOW to Replace GreaseAllgemeine Vorsichtsmassnahmen DeutschTechnische Daten Vorsichtsmassnahmen BEI DER Benutzung DES BohrhammersStandardzubehör Sonderzubehör separat zu beziehenVOR Inbetriebnahme AnwendungsgebieteEinsatz DES Bohrhammers Verwendung Einer BohrkroneWartung UND Inspektion SchmierfettwechselFrançais Precautions Generales DE TravailAccessoires Standard Precautions Pour L’UTILISATION DU Perforateur PercussionAccessoires EN Option vendus séparément CaracteristiquesUtilisation Avant LA Mise EN MarcheUtilisation DE LA Couronne RemarqueEntretien ET Inspection Comment Remplacer LA GraisseItaliano Precauzioni GeneraliAttenzione Accessori Disponibili a Richiesta venduti separatamente Accessori StandardPrecauzioni PER L’USO DEL Trapano a Percussione CaratteristichePrima DELL’USO ApplicazioniModo D’USO NotaCome Usare LA Corona Sostituzione DEL GrassoManutenzione E Controllo Algemene Voorzorgmaatregelen Italiano NederlandsTechnische Gegevens Standaard ToebehorenExtra Toebehoren los te verkrijgen Voor HET Gebruik ToepassingenGebruik OpmerkingGebruik VAN EEN Kernstuk Verversen VAN OlieLET OP Onderhoud EN Inspectie Nederlands EspañolPrecauciones Generales Para LA Operacion AantekeningPrecauciones AL Usar EL Martillo Perforador EspecificacionesAccesorios Estandar De venta por separado Accesorios FacultativosAplicaciones Antes DE LA Puesta EN MarchaModo DE Utilizacion DEL Martillo Perforador USO DE Barrena TubularPrecaucion Cambio DE Grasa Mantenimiento E InspeccionObservacion Page Page 4MM EC Declaration of Conformity Dichiarazione DI Conformità CE