Cisco Systems ASR9001, 9001S Over-temperature Conditions, Isolating Cooling Subsystem Problems

Page 87

Chapter 4 Troubleshooting the Installation

Troubleshooting the Cooling Subsystem

For additional power supply troubleshooting information, see the “Troubleshooting the Power

Subsystem” section on page 4-3.

Note For the RSP to communicate properly to a power module, input power to at least one of the two power modules should be present.

Over-temperature Conditions

This console error message indicates that the system has detected an over-temperature condition or out-of-tolerance power value inside the system:

Queued messages:

%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown

The preceding message could also indicate a faulty component or temperature sensor. Enter the show environment command or the show environment all command at the user EXEC prompt to display information about the internal system environment. The information generated by these commands includes:

Voltage measurements on each card from the DC-to-DC converter

The +5 VDC for the I2C module

Operating voltage for the fan tray

Temperature measurements received by all sensors of RP and LC module as well as temperature measurements from sensors located in each power module

If an environmental shutdown results from an over-temperature or out-of-tolerance condition, the Fault indicator on the power supply lights before the system shuts down.

Although an over-temperature condition is unlikely at initial system startup, make sure that:

Heated exhaust air from other equipment in the immediate environment is not entering the chassis card cage vents.

You allow sufficient air flow by maintaining a minimum of 6 inches (15.24 cm) of clearance at both the inlet and exhaust openings on the chassis and the power modules to allow cool air to enter freely and hot air to be expelled from the chassis.

Isolating Cooling Subsystem Problems

Use this procedure to isolate a problem with the chassis cooling system if you have an over-temperature condition:

Step 1 Make sure the fan tray is operating properly when you power on the system. To determine if the fan tray is operating, check the LED indicator on the fan tray front panel:

OK (green)—Fan tray is functioning properly and receiving +12 VDC power, indicating that the cables from the chassis backplane to the fan tray are good.

Fail (red)—Fault is detected in the fan tray. Replace the fan tray.

If neither indicator is on and the blower is not operating, there may be a problem with either the fan tray or the +12 VDC power supplied to the fan tray. Go to Step 2.

 

 

Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide

 

 

 

 

 

 

OL-26701-02

 

 

4-19

 

 

 

 

 

Image 87
Contents Text Part Number OL-26701-02 Americas HeadquartersPage Cisco ASR 9001 Router Cable Management Status LEDs Site Log B-1 Revision Date Change Summary Changes to This DocumentAudience PurposeDocument Conventions Document OrganizationObtaining Documentation and Submitting a Service Request OL-26701-02 Preparing for Installation General Safety Guidelines Safety GuidelinesCompliance and Safety Information Laser SafetyEnergy Hazard Lifting Guidelines Preventing Electrostatic Discharge DamageSite Requirement Guidelines Site Layout and Equipment DimensionsRear of chassis Chassis Air Flow Guidelines Site Wiring GuidelinesAir exhaust Room air Rack-Mounting and Air Flow Clearance GuidelinesEquipment Rack Types Telco 2-Post RackEnclosed Rack with Perforated Sides Open 4-Post RackAir Flow Guidelines for Enclosed Rack Installation Power Connection Guidelines Temperature and Humidity GuidelinesAC Power Cord Illustrations AC Powered RoutersAC Power Cord CAB-AC 12 AC Power Cord CAB-ACI 15 AC Power Cord CAB-ACU 18 AC Power Cord CAB-9K10A-EU DC Powered Router20 DC Power Cable Terminal Block 331933 Nebs Supplemental Unit Bonding and Grounding Guidelines 23 Cisco ASR 9001 Router Front Panel Ports Cisco ASR 9001 Router Port Connection GuidelinesSMB Port NameDescription MLT3Console Port Signals Signal Input/Output DescriptionConsole Port and Auxiliary Port Connection Guidelines Auxiliary Port Signals 10Base-T, 100Base-TX Signal 1000Base-T SignalManagement LAN Ports Connection Guidelines Management LAN RJ-45 Cabling Management LAN Port LED IndicatorsSync Ports Connection Guidelines Sync Port LED IndicatorsRP External USB Port Pin SignalOL-26701-02 Installation Overview Pre-Installation Considerations and RequirementsRequired Tools and Equipment Unpacking the Cisco ASR 9001 RouterPositioning the Router Verifying Rack Dimensions Installing the Chassis in a 2-Post RackRack-Mounting the Router Chassis Page Correct Lifting Positions Supplemental Bonding and Grounding Connections Installing the Chassis in a 4-post RackNebs Bonding and Grounding for the Cisco ASR 9001 Router Fixed 4x10-Gigabit Ethernet Ports Installing Modules and Cables in the ChassisPort Gigabit Ethernet Modular Port Adapter Modular Port AdaptersPort 10 Gigabit Ethernet Modular Port Adapter LED Label Color State MeaningStatus 4-Port 10 Gigabit Ethernet Modular Port Adapter 2-Port 10 Gigabit Ethernet Modular Port Adapter Installing and Removing Modular Port AdaptersOnline Insertion and Removal Handling Modular Port Adapters MPAsGE MPA Modular Port Adapter MPA Installation and RemovalVerifying the Installation Optical Device Installation and RemovalChecking the Installation Cleaning Optical DevicesPage Command Type of Information Provided Using the ping Command to Verify Network ConnectivityInstalling and Removing XFP Modules Installing and Removing SFP ModulesInstalling a Cable Management Tray Cable ManagementCable Management Tray Removing a Cable-Management Tray Cable-Management Tray Installation and RemovalCable Management Bracket Installing a Cable Management BracketRemoving a Cable-Management Bracket Cable-Management Bracket Installation and Removal10 RP Console and Auxiliary Port Connections Connecting Route Processor CablesConnecting to the RP Console Port Connecting to the RP Auxiliary PortConnecting to the RP Ethernet Management Ports Connecting Power to an AC-Powered Router Connecting Power to the RouterProceed to the Powering on the Router section on Negative to negative Connecting Power to a DC-Powered Router12 Typical Power Connections for a Single DC Power Module Powering on the RouterOL-26701-02 Troubleshooting Using a Subsystem Approach Troubleshooting OverviewNormal Router Startup Sequence Identifying Startup IssuesTroubleshooting the AC-Input Power Subsystem Troubleshooting the Power SubsystemLED Power Module Status IndicatorsTroubleshooting a DC Power Module Troubleshooting the DC-Input Power SubsystemHardware ID Additional Power Subsystem Troubleshooting InformationObtaining Temperature and Environmental Information Hardware and Software IdentificationTroubleshooting the Installation 8VLGTNG Troubleshooting the Power Distribution SystemRoute Processor Overview Troubleshooting the Route Processor SubsystemRP Front Panel Indicators Indicator LabelColor Description Auxiliary and Console Ports Ethernet Ports and Status LEDsStatus LEDs Troubleshooting the Line CardMonitoring Critical, Major, and Minor Alarm Status Initial Boot ProcessMTU Configuring and Troubleshooting Line Card InterfacesConfiguration Parameters Parameter Configuration File Entry Default ValueUsing Configuration Commands Basic Line Card ConfigurationLine Card Interface Address Verifying the Transceiver Modules PID XFP-10G-MM-SR Show logging Show diag slot Show context location slot Advanced Line Card TroubleshootingTroubleshooting the Cooling Subsystem Power Module FansFan Tray Operation Isolating Cooling Subsystem Problems Over-temperature ConditionsOL-26701-02 Field Replaceable Units Prerequisites and PreparationRemoving and Replacing the Fan Tray Powering Off the RouterRemoving and Replacing AC or DC Power System Components Power Module Replacement Guidelines Removing and Replacing an AC or DC Power ModuleRemoving an AC or DC Power Module Removing a Chassis from the Equipment Rack Installing an AC or DC Power ModulePacking a Chassis for Shipment Installing a Replacement Chassis in the Equipment RackTechnical Specifications Description Value Table A-3 Cisco ASR 9001 AC Electrical Specifications Minimum Maximum Range Nominal Range Minimum Nominal MaximumParameter Value Typical Maximum Part Number Description Wavelength Fiber Type DistancePart Number Description Part Number Description Wavelength Color IdentifierITU Grid Part Number Description Wavelength ITU Grid XFP-10G-MM-SR Fiber Type DistanceXFP-10GLR-OC192SR XFP-10GZR-OC192LRDWDM-XFP-C OL-26701-02 Site Log Appendix B Site Log Numerics IN-2 EMI See EMILink CwdmLED Dwdm ACTIN-5 NebsIN-6 IN-7 IN-8