Appendix A Technical Specifications
Table
Table | Cisco ASR 9001 AC Electrical Specifications | |
|
|
|
Description |
| Value |
|
| |
Power modules per system | Up to two AC power modules per system | |
|
| |
Total AC input power | 765 VA | |
|
| (up to two AC power supply modules per system) |
|
| |
Rated input voltage1 | ||
|
| |
|
| |
Rated input line frequency1 | 50/60 Hz nominal (range: 47 to 63 Hz) | |
|
| 50/60 Hz (UK) |
|
| |
Input current rating1 | 15 A maximum at 100 VAC | |
|
| 13 A maximum at 220 to 240 VRMS (UK) |
|
| |
Source AC service | 15 A North America and Japan; 10 A international; 13 A UK | |
requirement1 |
|
|
Redundancy |
| Power redundancy requirements vary, based on system configuration |
|
| (number and type of line cards, etc). AC powered systems are 2N |
|
| protected and DC powered systems are N+1 protected. |
|
|
|
1. For each AC power supply module.
Caution Be sure that the chassis configuration complies with the required power budgets. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.
Table
Table
Description | Value |
|
|
Power modules per system | Up to two DC power modules per system |
|
|
Total DC input power per | 750 W |
power module |
|
|
|
Rated input voltage per | |
power module | |
| (range: |
|
|
Input current rating1 | 15 A maximum at |
| 15 A maximum at |
|
|
Source DC service | Sufficient to supply the rated input current. Local codes apply. |
requirement1 |
|
Redundancy | Power redundancy requirements vary, based on system configuration |
| (number and type of line cards, etc). AC powered systems are 2N |
| protected and DC powered systems are N+1 protected. |
|
|
1.For each DC power supply module. Some power/chassis configurations may operate at lower current ratings than those specified in this table. Contact your Cisco technical representative for more information.
Cisco ASR 9001 and Cisco ASR
| ||
|