Cisco Systems ASR9001s, 9001S Troubleshooting the Line Card, Initial Boot Process, Status LEDs

Page 80

Chapter 4 Troubleshooting the Installation

Troubleshooting the Line Card

Monitoring Critical, Major, and Minor Alarm Status

Alarms warn of:

Overtemperature condition on a component in the card

Fan failure in the fan tray

Overcurrent condition in a power supply

Out-of-tolerance voltage on the card

The alarm LEDs are controlled by the CAN microcontoller software, which sets the threshold levels for triggering the different stages of alarms.

The RP card continuously polls the system for temperature, voltage, current, and fan speed values. If a threshold value is exceeded, the RP sets the appropriate alarm severity level on the alarm card, which lights the corresponding LED, and energizes the appropriate alarm display relays to activate any external audible or visual alarms wired to the alarm display. The RP also logs a message about the threshold violation on the system console.

Note If one or more of the alarm LEDs is on, check the system console for messages describing the alarm.

Troubleshooting the Line Card

Initial Boot Process

During a typical line card boot process, thse events occur:

1.The line card receives power and begins executing initialization software.

2.The line card performs internal checks, and prepares to accept the Cisco IOS XR software from the RP.

3.The RP loads the line card with its Cisco IOS XR software.

To verify that the line card is working properly:

Step 1 Check that the LC FAIL LED is ON (green) to verify that the card is operating normally.

Step 2 Check that the RSP FAIL LED for the port of interest is ON (green or blinking) to verify that the port is

active. If the RSP FAIL LED is not ON, verify that the associated interface is not shut down.

Step 3 If one of the conditions above is not met, see the “Advanced Line Card Troubleshooting” section on page 4-17to identify any possible problems.

Status LEDs

You can use the LC FAIL LED or the RSP FAIL LED on the RP card front panel to verify proper operation or troubleshoot a failure (see Table 4-4).

 

Cisco ASR 9001 and Cisco ASR 9001-S Routers Hardware Installation Guide

4-12

OL-26701-02

Image 80
Contents Americas Headquarters Text Part Number OL-26701-02Page Cisco ASR 9001 Router Cable Management Status LEDs Site Log B-1 Changes to This Document AudiencePurpose Revision Date Change SummaryDocument Organization Document ConventionsObtaining Documentation and Submitting a Service Request OL-26701-02 Preparing for Installation Safety Guidelines General Safety GuidelinesEnergy Hazard Compliance and Safety InformationLaser Safety Preventing Electrostatic Discharge Damage Lifting GuidelinesSite Layout and Equipment Dimensions Site Requirement GuidelinesRear of chassis Site Wiring Guidelines Chassis Air Flow GuidelinesRack-Mounting and Air Flow Clearance Guidelines Air exhaust Room airTelco 2-Post Rack Equipment Rack TypesOpen 4-Post Rack Enclosed Rack with Perforated SidesAir Flow Guidelines for Enclosed Rack Installation Temperature and Humidity Guidelines Power Connection GuidelinesAC Powered Routers AC Power Cord IllustrationsAC Power Cord CAB-AC 12 AC Power Cord CAB-ACI 15 AC Power Cord CAB-ACU DC Powered Router 18 AC Power Cord CAB-9K10A-EU20 DC Power Cable Terminal Block 331933 Nebs Supplemental Unit Bonding and Grounding Guidelines Cisco ASR 9001 Router Port Connection Guidelines 23 Cisco ASR 9001 Router Front Panel PortsPort Name DescriptionMLT3 SMBConsole Port and Auxiliary Port Connection Guidelines Console Port SignalsSignal Input/Output Description Management LAN Ports Connection Guidelines Auxiliary Port Signals10Base-T, 100Base-TX Signal 1000Base-T Signal Management LAN Port LED Indicators Management LAN RJ-45 CablingSync Port LED Indicators Sync Ports Connection GuidelinesPin Signal RP External USB PortOL-26701-02 Pre-Installation Considerations and Requirements Installation OverviewUnpacking the Cisco ASR 9001 Router Required Tools and EquipmentPositioning the Router Rack-Mounting the Router Chassis Verifying Rack DimensionsInstalling the Chassis in a 2-Post Rack Page Correct Lifting Positions Installing the Chassis in a 4-post Rack Supplemental Bonding and Grounding ConnectionsNebs Bonding and Grounding for the Cisco ASR 9001 Router Installing Modules and Cables in the Chassis Fixed 4x10-Gigabit Ethernet PortsModular Port Adapters Port Gigabit Ethernet Modular Port AdapterStatus Port 10 Gigabit Ethernet Modular Port AdapterLED Label Color State Meaning 4-Port 10 Gigabit Ethernet Modular Port Adapter Installing and Removing Modular Port Adapters 2-Port 10 Gigabit Ethernet Modular Port AdapterHandling Modular Port Adapters MPAs Online Insertion and RemovalModular Port Adapter MPA Installation and Removal GE MPAOptical Device Installation and Removal Checking the InstallationCleaning Optical Devices Verifying the InstallationPage Using the ping Command to Verify Network Connectivity Command Type of Information ProvidedInstalling and Removing SFP Modules Installing and Removing XFP ModulesCable Management Tray Installing a Cable Management TrayCable Management Cable-Management Tray Installation and Removal Removing a Cable-Management TrayInstalling a Cable Management Bracket Cable Management BracketCable-Management Bracket Installation and Removal Removing a Cable-Management BracketConnecting Route Processor Cables 10 RP Console and Auxiliary Port ConnectionsConnecting to the RP Ethernet Management Ports Connecting to the RP Console PortConnecting to the RP Auxiliary Port Connecting Power to the Router Connecting Power to an AC-Powered RouterProceed to the Powering on the Router section on Connecting Power to a DC-Powered Router Negative to negativePowering on the Router 12 Typical Power Connections for a Single DC Power ModuleOL-26701-02 Troubleshooting Overview Troubleshooting Using a Subsystem ApproachIdentifying Startup Issues Normal Router Startup SequenceTroubleshooting the Power Subsystem Troubleshooting the AC-Input Power SubsystemPower Module Status Indicators LEDTroubleshooting the DC-Input Power Subsystem Troubleshooting a DC Power ModuleAdditional Power Subsystem Troubleshooting Information Obtaining Temperature and Environmental InformationHardware and Software Identification Hardware IDTroubleshooting the Installation Troubleshooting the Power Distribution System 8VLGTNGTroubleshooting the Route Processor Subsystem Route Processor OverviewColor Description RP Front Panel IndicatorsIndicator Label Ethernet Ports and Status LEDs Auxiliary and Console PortsTroubleshooting the Line Card Monitoring Critical, Major, and Minor Alarm StatusInitial Boot Process Status LEDsConfiguring and Troubleshooting Line Card Interfaces Configuration ParametersParameter Configuration File Entry Default Value MTULine Card Interface Address Using Configuration CommandsBasic Line Card Configuration Verifying the Transceiver Modules PID XFP-10G-MM-SR Advanced Line Card Troubleshooting Show logging Show diag slot Show context location slotFan Tray Operation Troubleshooting the Cooling SubsystemPower Module Fans Over-temperature Conditions Isolating Cooling Subsystem ProblemsOL-26701-02 Prerequisites and Preparation Field Replaceable UnitsPowering Off the Router Removing and Replacing the Fan TrayRemoving and Replacing AC or DC Power System Components Removing an AC or DC Power Module Power Module Replacement GuidelinesRemoving and Replacing an AC or DC Power Module Installing an AC or DC Power Module Removing a Chassis from the Equipment RackInstalling a Replacement Chassis in the Equipment Rack Packing a Chassis for ShipmentTechnical Specifications Description Value Table A-3 Cisco ASR 9001 AC Electrical Specifications Parameter Value Minimum Maximum Range NominalRange Minimum Nominal Maximum Part Number Description Typical MaximumPart Number Description Wavelength Fiber Type Distance ITU Grid Part Number Description WavelengthColor Identifier Part Number Description Wavelength ITU Grid Fiber Type Distance XFP-10GLR-OC192SRXFP-10GZR-OC192LR XFP-10G-MM-SRDWDM-XFP-C OL-26701-02 Site Log Appendix B Site Log Numerics IN-2 See EMI EMICwdm LED DwdmACT LinkNebs IN-5IN-6 IN-7 IN-8