Siemens FC330A manual ECopyright by Siemens Building Technologies AG

Page 2

Data and design subject to change without notice. / Supply subject to availability.

ECopyright by

Siemens Building Technologies AG

Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger anerkennt diese Rechte und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder ausserhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.

We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.

Nous nous réservons tous les droits sur ce document, ainsi que sur l’objet y figurant. La partie recevant ce document reconnaît ces droits et elle s’engage à ne pas le rendre accessible à des tiers, même partiellement, sans notre autorisation écrite préalable et à ne pas l’employer à des fins autres que celles pour lesquelles il lui a été remis.

Ci riserviamo ogni diritto relativo al presente documento e sull’oggetto illustrato in esso. La parte che riceve il documento si impegna a non renderlo accessibile a terzi, né per intero né in parte, senza la nostra previa autorizzazione scritta ed a non usarlo per altri scopi di quello per il quale è stato rilasciato.

Image 2
Contents Synova FC330A Fire detection system Fire & Security ProductsPhase Operating manual System operation for userECopyright by Siemens Building Technologies AG Overview operating menu Siemens Building Technologies Group Fire & Security Products06.2003 e1973c-1 IntroductionFire & Security Products Siemens Building Technologies GroupPage e1973c-2 FundamentalsFire & Security Products Siemens Building Technologies GroupControl console FC330A Control console layout1 ALARM B3Q590/595 Floor panelB3Q580 Overview operating menu page 4.other functionsonly for service engineer 4.other functionsFundamental operation How to operate the control consoleWhat is “normal operation”? Normal operationALARM Mains interruptionHow do I get operating access? Operating accessPossible access levels Log out Operating access via passwordLog in Operating “manned” and “unmanned” Basic rulesAutomatic switchover Extra timee1973c-3 AlarmFire & Security Products Siemens Building Technologies GroupSPECIAL Alarm Concept Purpose and principleV2 = Alarm investigation timeV1 = Principle AlarmALARM What to do after an alarm How are alarm messages shown on the text display?How to respond in case of alarm Scrolling alarm messagesSiemens Building Technologies Group Fire & Security Productse1973c-3 02.2004e1973c-4 Disable/Enable System PartsFire & Security Products Siemens Building Technologies GroupWhen has a detector zone to be isolated? Temporary isolation of a detector zoneWhat is a detector zone? Zone isolation procedure Disable all zones Viewing disabled zonesZone reactivation procedure Several zones disabledEnable all disabled zones Enable single zonesEnable a range of zones Single detector isolation procedure Temporary isolation of a single detectorWhen has a single detector to be isolated? Detector reactivation procedure When has the remote transmission to be disabled? Remote TransmissionWhat is “remote transmission”? Disabling the remote alarm transmission facilityDisabling the remote fault transmission facility Enabling the remote fault transmission facilityDisabling the alarm devices Alarm devicesWhen have alarm devices to be disabled? Enabling alarm devicese1973c-7 FaultsFire & Security Products Siemens Building Technologies GroupReset FaultsHow do I respond to fault messages? What remedies are available to the user?e1973c-8 MaintenanceFire & Security Products Siemens Building Technologies GroupRecommendations for function tests Detector testPurpose and Principle 4.After entering the last number press ok twice Test procedure for detector tester RE6T Functional testing of automatic AlgoRex-detectorsTest procedure for detector tester RE6 Required equipementFunctional test of manual call points Test procedure for type KACTest procedure for type DIN indirect activation Control consolePurpose of the lamp test Lamp testLamp test procedure Purpose and principle Battery load testBattery load test procedure Purpose and principle Test of acoustic alarm devicesHorn test procedure Test procedure for remote fault transmission Test of Remote Transmission RTTest procedure for remote alarm transmission Purpose and principleSiemens Building Technologies Group Fire & Security Productse1973c-12 02.2004e1973c-13 Other FunctionsFire & Security Products Siemens Building Technologies GroupDisabling the printer Printer disabling/enablingWhen has the printer to be disabled? Enabling the printerEnable the printer Paper replacement with logging printer B2Q191Switch off the printer Change of printer paperPolling the alarm counter Poll alarm counterPurpose of polling the alarm counter Polling the event memory Poll event memoryPurpose of polling the event memory Polling user text of zones or elements Poll user text of zones or elementsPurpose Polling the system status Poll system statusPurpose Polling configuration data of address lines Poll configuration dataPolling configuration data of detector zones PurposePrint configuration/user text PrintoutPrint event memory/alarm counter Print configuration zone/line/LONSet time and date Set time and datePurpuse and Principle Page Document no. e1973c Siemens Building Technologies AG Alte LandstrasseCH-8708Männedorf Tel. +41 1 − Edition