Teledyne powerpod 400 instruction manual Front Panel, Channel Number Select Keys

Page 10

5.0 Front Panel

 

OPEN

1

2

3

1

CLOSE

 

 

 

 

 

OPEN

4

5

6

2

CLOSE

 

 

 

 

 

OPEN

7

8

9

3

CLOSE

 

 

 

 

 

OPEN

0 .

 

4

CLOSE PowerPod400

 

 

HASTINGS

 

 

1.CHANNEL NUMBER SELECT KEYS

Selects channel for editing. An asterisk (*) appears in the first column of the display to indicate that this is the channel to be edited.

2.OVERRIDE INDICATORS

Indicates when a channel’s command signal is overridden high (OPEN) or low (CLOSED).

3.OVERRIDE KEYS

Override the command signal on the ACTIVE CHANNEL. OPEN sets control override (pin 8) to +15V. CLOSED sets command to –15V. AUTO allows the user to set the command signal for normal operation. A channel must be active before these keys can become operational.

4.DISPLAY AREA

Column 1:

Reserved for displaying ACTIVE CHANNEL (*), MASTER channel (M), SLAVE (S) or

 

TOTAL (T).

Column 2:

Reserved for polarity indicator.

Col’s 3 – 8:

Signal monitor. Displays current input signal while in METER mode, AVERAGE while set

 

to average readings or TOTAL while in TOTALIZER mode.

Column 9:

Space

Col’s 10 – 14:

UNITS OF MEASURE display.

Column 15:

Space

Col’s 16 – 20:

GAS ID.

5.KEYPAD

Use to enter SET POINTS or to modify the SETUP or CALIBRATION of control unit.

164-122012 PowerPOD 400

Page 10 of 42

Image 10
Contents Teledyne Hastings Manual Print History Table of Contents Four to Twenty Milliamp Operation Power Quick Start InstructionsSafety Features Front Panel LockoutPower Selection Specifications PowerPod-400 Specifications TableFront Panel Channel Number Select KeysRear Panel Power WiringCommunications Alarms Transducer ConnectionsAnalog Signal Followers Manual Operation Power ON/OFFChanging the Command SET Point Override OpenSetting a Channel to Directly Meter Incoming Signals Setting a Channel to Auto ControlSetting a Channel to Display the Totalizer Function Mode Reset Value Choosing RS-232 Communication External/Remote OperationChoosing RS-485 Communication Display Setup Setup/Cal ModeEntering the SETUP/CAL Mode Blanking a Display Line/ChannelSelecting Unit-of-Measure Setting A/D Conversion Rate FilterSelecting Gas ID Front Panel Lock Out Totalizer SetupCount Up to a Set Point RS-485 Settings External Communication SetupRS-232 Settings Count Down from a Set PointZero to Ten Volt Operation Selecting the Analog Signal LevelZero to Five Volt Operation Four to Twenty Milliamp OperationSetting a Single Channel’s Low Limit Setting Limit AlarmsSetting a Single Channel’s High Limit Setting a Single Channel’s HysteresisSetting Ratio Control Parameters Enabling Ratio ControlResetting the Zero Only Calibrating a Channel to ITS Incoming SignalsResetting the Span Only Resetting Zero and Span Setting a Multiplication FactorSerial Communication CommandsAlarm/Flag Queries Set Point QueriesPowerPOD PowerPod-400 Serial Commands Appendix aPowerPod-400 Serial Commands Contd Appendix a Notes ApppendixCB Name Rate TotalGas ID Table Page 1 Gas ID Table Page 2 Setting the Zero & Span PowerPod-400 Power Supply/Totalizer Appendix DZeroing Unit 4 to 20 mA Range Spanning Unit Transducer POWERPOD-400 PowerPOD Drawings Warranty Warranty Repair Policy