Teledyne powerpod 400 instruction manual Gas ID Table Page 2

Page 35

Gas ID Table (Page 2 of 2)

 

GAS NAME

Symbol

 

GAS NAME

Symbol

 

GAS NAME

Symbol

136

Pentane

C5H12

156

R143

R143

175

Toluene

C7H8

137

Perchloryl Fluoride

ClFO3

157

R143A

R143A

176

Transbutene

C4H8

138

Perfluorocyclobutane

C4F8

158

R152A

R152A

177

Trichloroethane

177

139

R116

C2F6

159

R218

C3F8

178

Trichloroethylene

178

140

Perfluoropropane

C3F8

160

R1416

R1416

179

R113

R113

141

Phenol

C6H6O

161

Radon

Rn

180

Triethylamine

180

142

Phosgene

COCl2

162

Sec-butanol

162

181

Trimethyl Amine

C3H9N

143

Phosphine

PH3

163

Silane

SiH4

182

Tungsten Hexafluoride

WF6

144

Phosphorus Trifluoride

PF3

164

Silicone Tetrafluoride

SiF4

183

Uranium Hexafluoride

UF6

145

Propane

C3H8

165

Sulfur Dioxide

SO2

184

Vinyl Bromide

184

146

Propyl Alcohol

C3H8O

166

Sulfur Hexafluoride

SF6

185

Vinyl Chloride

185

147

Propyl Amine

C3H9N

167

Sulfur Tetrafluoride

SF4

186

Vinyl Flouride

C2H3F

148

Propylene

C3H6

168

Sulfur Trifluoride

SF3

187

Water Vapor

H2O

149

Pyradine

C5H5N

169

Sulfur Trioxide

SO3

188

Xenon

Xe

150

R32

CH2F2

170

Tetrachloroethylene

170

189

Xylene, m-

C8H10

151

R123

R123

171

Tetrafluoroethylene

C2F4

190

Xylene, o-

C8H10

152

R123A

R123A

172

Tetrahydrofuran

C4H8O

191

Xylene, p-

C8H10

153

R125

C2HF5

173

Tert-butanol

173

191

Mixtures

MIXT

154

R134

R134

174

Thiophene

C4H4S

193

Other

????

155

R134A

R134A

 

 

 

194

 

 

 

 

 

 

 

 

 

 

 

164-122012 PowerPOD 400

Page 35 of 42

Image 35
Contents Teledyne Hastings Manual Print History Table of Contents Four to Twenty Milliamp Operation Quick Start Instructions PowerSafety Front Panel Lockout FeaturesPower Selection PowerPod-400 Specifications Table SpecificationsChannel Number Select Keys Front PanelRear Panel Communications WiringPower Transducer Connections AlarmsAnalog Signal Followers Override Open Power ON/OFFChanging the Command SET Point Manual OperationSetting a Channel to Display the Totalizer Function Setting a Channel to Auto ControlSetting a Channel to Directly Meter Incoming Signals Mode Reset Value Choosing RS-485 Communication External/Remote OperationChoosing RS-232 Communication Blanking a Display Line/Channel Setup/Cal ModeEntering the SETUP/CAL Mode Display SetupSelecting Gas ID Setting A/D Conversion Rate FilterSelecting Unit-of-Measure Count Up to a Set Point Totalizer SetupFront Panel Lock Out Count Down from a Set Point External Communication SetupRS-232 Settings RS-485 SettingsFour to Twenty Milliamp Operation Selecting the Analog Signal LevelZero to Five Volt Operation Zero to Ten Volt OperationSetting a Single Channel’s Hysteresis Setting Limit AlarmsSetting a Single Channel’s High Limit Setting a Single Channel’s Low LimitEnabling Ratio Control Setting Ratio Control ParametersResetting the Span Only Calibrating a Channel to ITS Incoming SignalsResetting the Zero Only Setting a Multiplication Factor Resetting Zero and SpanSet Point Queries CommandsAlarm/Flag Queries Serial CommunicationPowerPOD Appendix a PowerPod-400 Serial CommandsPowerPod-400 Serial Commands Contd Appendix a Notes Name Rate Total ApppendixCBGas ID Table Page 1 Gas ID Table Page 2 Appendix D Setting the Zero & Span PowerPod-400 Power Supply/TotalizerZeroing Unit 4 to 20 mA Range Spanning Unit Transducer POWERPOD-400 PowerPOD Drawings Warranty Repair Policy Warranty