Teledyne powerpod 400 instruction manual Appendix a Notes

Page 32

APPENDIX A (Notes:)

1.All returned values will include decimal points wherever unit has been programmed to display them.

2.All Commands needing decimal points must include them wherever they are intended to be displayed.

3.d = decimal digit (ASCII)

4.n = Channel Number

 

Dnd : n = Chnl #

 

 

 

d = 1, Displays Total Units (Mass)

5.

d = 2, Displays Flow Units (Rate)

 

 

d = 3, Blanks selected channel

 

6. rz = range, zero; . rfs = range, full scale

 

 

INnd : n = Chnl #

 

 

 

d = 1, 0 5 VDC

 

 

7.

 

 

d = 2, 0 10 VDC

 

 

 

 

 

 

d = 3, 4 20 mADC

 

 

 

 

 

 

TnMd : n = Chnl #

 

 

 

 

d = 1, Totalizer Counts Up, Re sets to Zero

8.

d = 2, Totalizer Counts Down, Re sets to Set Po int

 

 

d = 3, Totalizer Counts Continuously, Re sets to Zero

 

 

TFnd : n = Chnl #

 

 

9.

d = 0, Total < Set Po int

 

 

 

d = 1, Total Set Po int

 

 

 

10.text = “OPEN” or “CLOSE” d = 0 or 1

 

Rnd : n = Chnl #

 

 

11.

d = 1 = Enabled

 

 

 

d = 2, Disabled

 

 

 

12.

BRd :

d = 1, 9600

 

 

d = 2, 19200

 

 

 

 

 

13.

REd :

d = 1, LOCAL

 

d = 2, REMOTE

 

164-122012 PowerPOD 400

Page 32 of 42

Image 32
Contents Teledyne Hastings Manual Print History Table of Contents Four to Twenty Milliamp Operation Power Quick Start InstructionsSafety Features Front Panel LockoutPower Selection Specifications PowerPod-400 Specifications TableFront Panel Channel Number Select KeysRear Panel Communications WiringPower Alarms Transducer ConnectionsAnalog Signal Followers Power ON/OFF Changing the Command SET PointManual Operation Override OpenSetting a Channel to Display the Totalizer Function Setting a Channel to Auto ControlSetting a Channel to Directly Meter Incoming Signals Mode Reset Value Choosing RS-485 Communication External/Remote OperationChoosing RS-232 Communication Setup/Cal Mode Entering the SETUP/CAL ModeDisplay Setup Blanking a Display Line/ChannelSelecting Gas ID Setting A/D Conversion Rate FilterSelecting Unit-of-Measure Count Up to a Set Point Totalizer SetupFront Panel Lock Out External Communication Setup RS-232 SettingsRS-485 Settings Count Down from a Set PointSelecting the Analog Signal Level Zero to Five Volt OperationZero to Ten Volt Operation Four to Twenty Milliamp OperationSetting Limit Alarms Setting a Single Channel’s High LimitSetting a Single Channel’s Low Limit Setting a Single Channel’s HysteresisSetting Ratio Control Parameters Enabling Ratio ControlResetting the Span Only Calibrating a Channel to ITS Incoming SignalsResetting the Zero Only Resetting Zero and Span Setting a Multiplication FactorCommands Alarm/Flag QueriesSerial Communication Set Point QueriesPowerPOD PowerPod-400 Serial Commands Appendix aPowerPod-400 Serial Commands Contd Appendix a Notes ApppendixCB Name Rate TotalGas ID Table Page 1 Gas ID Table Page 2 Setting the Zero & Span PowerPod-400 Power Supply/Totalizer Appendix DZeroing Unit 4 to 20 mA Range Spanning Unit Transducer POWERPOD-400 PowerPOD Drawings Warranty Warranty Repair Policy