Teledyne powerpod 400 instruction manual PowerPod-400 Specifications Table

Page 9

4.0 Specifications

PowerPod-400 Specifications Table

 

Specification

Value

 

Units

 

Notes

 

Power Inputs

 

 

 

 

 

 

 

 

100

 

 

 

 

0.7 A, 250VAC, SB Fuse

 

V

115

 

 

VAC

 

0.6 A, 250VAC, SB Fuse

 

 

230

 

 

 

 

0.315 A, 250VAC, SB Fuse

 

P

68

 

 

VA

 

 

 

f

50 -60

 

 

Hz

 

 

 

 

 

 

 

 

 

 

 

Transducer

 

 

 

 

 

 

 

Number Channels

4

 

 

 

 

 

 

VSupply

±15

 

 

VDC

 

Bi-polar, per Channel

 

ISupply

±250

 

 

mA

 

Bi-polar, per Channel

 

 

0 - 5

 

 

VDC

 

 

 

I/O

0 - 10

 

 

 

 

 

 

 

 

 

 

 

 

4 - 20

 

 

mADC

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

Type

 

 

 

 

 

Vacuum Fluorescent,

 

 

 

 

 

 

LCD Emulator

 

 

 

 

 

 

 

 

# Lines

4

 

 

 

 

 

 

# Characters

20

 

 

 

 

 

 

Brightness Levels

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A/D Converter

 

 

 

 

 

 

 

Filtering Rate

4, 15, 30,

 

 

Hz

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarms

 

 

 

 

 

 

 

3 per channel

1 High

 

 

 

 

 

 

1 Low

 

 

 

 

 

 

1 Total

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

Front Panel (h x w)

3.5 x 9.5

 

in

 

 

 

Case (h x w x d)

3 x 8 x 9.5

 

in

 

 

 

Hole Centers (h x

3 x 8.825

 

in

 

 

 

w)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

5 1/4

 

 

lbs

 

 

164-122012 PowerPOD 400

Page 9 of 42

Image 9
Contents Teledyne Hastings Manual Print History Table of Contents Four to Twenty Milliamp Operation Quick Start Instructions PowerSafety Front Panel Lockout FeaturesPower Selection PowerPod-400 Specifications Table SpecificationsChannel Number Select Keys Front PanelRear Panel Wiring PowerCommunications Transducer Connections AlarmsAnalog Signal Followers Changing the Command SET Point Power ON/OFFManual Operation Override OpenSetting a Channel to Auto Control Setting a Channel to Directly Meter Incoming SignalsSetting a Channel to Display the Totalizer Function Mode Reset Value External/Remote Operation Choosing RS-232 CommunicationChoosing RS-485 Communication Entering the SETUP/CAL Mode Setup/Cal ModeDisplay Setup Blanking a Display Line/ChannelSetting A/D Conversion Rate Filter Selecting Unit-of-MeasureSelecting Gas ID Totalizer Setup Front Panel Lock OutCount Up to a Set Point RS-232 Settings External Communication SetupRS-485 Settings Count Down from a Set PointZero to Five Volt Operation Selecting the Analog Signal LevelZero to Ten Volt Operation Four to Twenty Milliamp OperationSetting a Single Channel’s High Limit Setting Limit AlarmsSetting a Single Channel’s Low Limit Setting a Single Channel’s HysteresisEnabling Ratio Control Setting Ratio Control ParametersCalibrating a Channel to ITS Incoming Signals Resetting the Zero OnlyResetting the Span Only Setting a Multiplication Factor Resetting Zero and SpanAlarm/Flag Queries CommandsSerial Communication Set Point QueriesPowerPOD Appendix a PowerPod-400 Serial CommandsPowerPod-400 Serial Commands Contd Appendix a Notes Name Rate Total ApppendixCBGas ID Table Page 1 Gas ID Table Page 2 Appendix D Setting the Zero & Span PowerPod-400 Power Supply/TotalizerZeroing Unit 4 to 20 mA Range Spanning Unit Transducer POWERPOD-400 PowerPOD Drawings Warranty Repair Policy Warranty