Teledyne powerpod 400 instruction manual ApppendixCB, Name Rate Total

Page 33

1213.0.0 ApppendixCB

Units-of-Measure for Meter Reading & Corresponding Totalizer Units

#

Name

Rate

Total

 

#

Name

Rate

Total

1

Standard Cubic Centimeters per Minute

SCCM

SCC

 

35

Standard Cubic Inches per Minute

SCIM

SCI

2

Standard Liters per Minute

SLM

SL

 

36

Normal Cubic Inches per Minute

NCIM

NCI

3

Percent

%

 

 

37

Standard Cubic Inches per Second

SCIS

SCI

4

Volts

V

 

 

38

Normal Cubic Inches per Second

NCIS

NCI

5

Millivolts

MV

 

 

39

Standard Cubic Inches per Hour

SCIH

SCI

6

Counts

CNT

 

 

40

Normal Cubic Inches per Hour

NCIH

NCI

7

Normal Liters per Minute

NLM

NL

 

41

Pounds per Minute

LBM

LB

8

Standard Liters per Second

SLS

SL

 

42

Pounds per Second

LBS

LB

9

Normal Liters per Second

NLS

NL

 

43

Pounds per Hour

LBH

LB

10

Standard Liters per Hour

SLH

SL

 

44

Kilograms per Minute

KgM

Kg

11

Normal liters per Hour

NLH

NL

 

45

Kilograms per Second

KgS

Kg

12

Standard Mililiters per Minute

SMLM

SML

 

46

Kilograms per Hour

KgH

Kg

13

Normal Mililiters per Minute

NMLM

NML

 

47

Grams per Minute

GRM

GR

14

Standard Mililiters per Second

SMLS

SML

 

48

Grams per Second

GMS

GR

15

Normal Mililters per Second

NMLS

NML

 

49

Grams per Hour

GRH

GR

16

Standard Mililiters per Hour

SMLH

SML

 

50

Moles per Minute

MolM

Mol

17

Normal Mililiters per Hour

NMLH

NML

 

51

Moles per Second

MolS

Mol

18

Normal Cubic Centimeters per Minute

NCCM

NCC

 

52

Moles per Hour

MolH

Mol

19

Standard Cubic Centimeters per Second

SCCS

SCC

 

53

Kilomoles per Minute

KMolM

KMol

20

Normal Cubic Centimeters per Second

NCCS

NCC

 

54

Kilomoles per Second

KMolS

KMol

21

Standard Cubic Centimeters per Hour

SCCH

SCC

 

55

Kilomoles per Hour

KMolH

KMol

22

Normal Cubic Centimeters per Hour

NCCH

NCC

 

56

Watts

W

 

23

Standard Cubic Feet per Minute

SCFM

SCF

 

57

Bits per Second

BPS

Bits

24

Normal Cubic Feet per Minute

NCFM

NCF

 

58

Seconds

Sec

 

25

Standard Cubic Feet per Second

SCFS

SCF

 

59

Minutes

Min

 

26

Normal Cubic Feet per Second

NCFS

NCF

 

60

Hours

Hrs

 

27

Standard Cubic Feet per Hour

SCFH

SCF

 

61

Watt * Hours

WH

W

28

Normal Cubic Feet per Hour

NCFH

NCF

 

62

Torr

Torr

 

29

Standard Cubic Meters per Minute

SCMM

SCM

 

63

Bar

Bar

 

30

Normal Cubic Meters per Minute

NCMM

NCM

 

64

Pascals

Pa

 

31

Standard Cubic Meters per Second

SCMS

SCM

 

65

Inches of Water

inH2O

 

32

Normal Cubic Meters per Second

NCMS

NCM

 

66

Pounds per Square Inch, Absolute

PSIA

 

33

Standard Cubic Meters per Hour

SCMH

SCM

 

67

Pounds per Square Inch, Gage

PSIG

 

34

Normal Cubic Meters per Hour

NCMH

NCM

 

 

 

 

 

164-122012 PowerPOD 400

Page 33 of 42

Image 33
Contents Teledyne Hastings Manual Print History Table of Contents Four to Twenty Milliamp Operation Quick Start Instructions PowerSafety Front Panel Lockout FeaturesPower Selection PowerPod-400 Specifications Table SpecificationsChannel Number Select Keys Front PanelRear Panel Wiring PowerCommunications Transducer Connections AlarmsAnalog Signal Followers Changing the Command SET Point Power ON/OFFManual Operation Override OpenSetting a Channel to Auto Control Setting a Channel to Directly Meter Incoming SignalsSetting a Channel to Display the Totalizer Function Mode Reset Value External/Remote Operation Choosing RS-232 CommunicationChoosing RS-485 Communication Entering the SETUP/CAL Mode Setup/Cal ModeDisplay Setup Blanking a Display Line/ChannelSetting A/D Conversion Rate Filter Selecting Unit-of-MeasureSelecting Gas ID Totalizer Setup Front Panel Lock OutCount Up to a Set Point RS-232 Settings External Communication SetupRS-485 Settings Count Down from a Set PointZero to Five Volt Operation Selecting the Analog Signal LevelZero to Ten Volt Operation Four to Twenty Milliamp OperationSetting a Single Channel’s High Limit Setting Limit AlarmsSetting a Single Channel’s Low Limit Setting a Single Channel’s HysteresisEnabling Ratio Control Setting Ratio Control ParametersCalibrating a Channel to ITS Incoming Signals Resetting the Zero OnlyResetting the Span Only Setting a Multiplication Factor Resetting Zero and SpanAlarm/Flag Queries CommandsSerial Communication Set Point QueriesPowerPOD Appendix a PowerPod-400 Serial CommandsPowerPod-400 Serial Commands Contd Appendix a Notes Name Rate Total ApppendixCBGas ID Table Page 1 Gas ID Table Page 2 Appendix D Setting the Zero & Span PowerPod-400 Power Supply/TotalizerZeroing Unit 4 to 20 mA Range Spanning Unit Transducer POWERPOD-400 PowerPOD Drawings Warranty Repair Policy Warranty