Teledyne powerpod 400 instruction manual PowerPod-400 Serial Commands Contd

Page 31

APPENDIX A (Cont.)

PowerPod-400 Serial Commands (Cont'd)

Command

Name

Query

Response

 

D1<d >

Ch1 Disp Mode

 

D1 d

note 5

D2<d>

Ch2 Disp Mode

 

D2 d

 

D3<d >

Ch3 Disp Mode

 

D3 d

 

D4<d >

Ch4 Disp Mode

 

D4 d

 

T1S<dddddd>

Totalizer Set Point, Ch1

T1S

T1S dddddd

 

T2S<dddddd>

Totalizer Set Point, Ch2

T2S

T2S dddddd

 

T3S<dddddd>

Totalizer Set Point, Ch3

T3S

T3S dddddd

 

T4S<dddddd>

Totalizer Set Point, Ch4

T4S

T4S dddddd

 

T1M<d>

Totalizer Mode, Ch1

T1M

T1M d

note 8

T2M<d>

Totalizer Mode, Ch2

T2M

T2M d

 

T3M<d>

Totalizer Mode, Ch3

T3M

T3M d

 

T4M<d>

Totalizer Mode, Ch4

T4M

T4M d

 

T1R

Totalizer Reset, Ch1

 

 

note 8

T2R

Totalizer Reset, Ch2

 

 

 

T3R

Totalizer Reset, Ch3

 

 

 

T4R

Totalizer Reset, Ch4

 

 

 

 

Totalizer Flag, Ch1

TF1

TF1 d

note 9

 

Totalizer Flag, Ch2

TF2

TF2 d

 

 

Totalizer Flag, Ch3

TF3

TF3 d

 

 

Totalizer Flag, Ch4

TF4

TF4 d

 

SN1<d.dddd>

Cal Value, CH1

SN1

SN1 d.dddd

notes 1, 2

SN2<dd.ddd>

Cal Value, CH2

SN2

SN2 d.dddd

 

SN3<ddd.dd>

Cal Value, CH3

SN3

SN3 d.dddd

 

SN4<dddd.d>

Cal Value, CH4

SN4

SN4 d.dddd

 

Z1

Zero Ch1

 

 

 

Z2

Zero Ch2

 

 

 

Z3

Zero Ch3

 

 

 

Z4

Zero Ch4

 

 

 

F1

Set Full Scale Value, Ch1

 

 

 

F2

Set Full Scale Value, Ch2

 

 

 

F3

Set Full Scale Value, Ch3

 

 

 

F4

Set Full Scale Value, Ch4

 

 

 

 

 

 

OCA: CH1 text CH2 text

Note 10

 

Status, All Channels

ST

CH3 text CH4 text

 

 

HI/LO: CH1 d/d CH2 d/d

 

 

 

 

 

 

 

 

CH3 d/d CH4 d/d

 

R1<d>

Ratio Mode, Ch1

R1

R1 d

note 11

R2<d>

Ratio Mode, Ch2

R2

R2 d

 

R3<d>

Ratio Mode, Ch3

R3

R3 d

 

R4<d>

Ratio Mode, Ch4

R4

R4 d

 

BR<d>

Baud Rate

BR

BR d

note 12

RE<d>

Front Panel Lock Out

RE

REn: REMOTE/LOCAL

note 13

*00X<dd>

Multi-drop Address

*00X

MULTIDROP ADDRESS: dd

164-122012 PowerPOD 400

Page 31 of 42

Image 31
Contents Teledyne Hastings Manual Print History Table of Contents Four to Twenty Milliamp Operation Quick Start Instructions PowerSafety Front Panel Lockout FeaturesPower Selection PowerPod-400 Specifications Table SpecificationsChannel Number Select Keys Front PanelRear Panel Power WiringCommunications Transducer Connections AlarmsAnalog Signal Followers Override Open Power ON/OFFChanging the Command SET Point Manual OperationSetting a Channel to Directly Meter Incoming Signals Setting a Channel to Auto ControlSetting a Channel to Display the Totalizer Function Mode Reset Value Choosing RS-232 Communication External/Remote OperationChoosing RS-485 Communication Blanking a Display Line/Channel Setup/Cal ModeEntering the SETUP/CAL Mode Display SetupSelecting Unit-of-Measure Setting A/D Conversion Rate FilterSelecting Gas ID Front Panel Lock Out Totalizer SetupCount Up to a Set Point Count Down from a Set Point External Communication SetupRS-232 Settings RS-485 SettingsFour to Twenty Milliamp Operation Selecting the Analog Signal LevelZero to Five Volt Operation Zero to Ten Volt OperationSetting a Single Channel’s Hysteresis Setting Limit AlarmsSetting a Single Channel’s High Limit Setting a Single Channel’s Low LimitEnabling Ratio Control Setting Ratio Control ParametersResetting the Zero Only Calibrating a Channel to ITS Incoming SignalsResetting the Span Only Setting a Multiplication Factor Resetting Zero and SpanSet Point Queries CommandsAlarm/Flag Queries Serial CommunicationPowerPOD Appendix a PowerPod-400 Serial CommandsPowerPod-400 Serial Commands Contd Appendix a Notes Name Rate Total ApppendixCBGas ID Table Page 1 Gas ID Table Page 2 Appendix D Setting the Zero & Span PowerPod-400 Power Supply/TotalizerZeroing Unit 4 to 20 mA Range Spanning Unit Transducer POWERPOD-400 PowerPOD Drawings Warranty Repair Policy Warranty