Sigma S2Ba, S2Ca warranty Identcode ordering system Dulcodes UV-Desinfektionsanlage

Page 10

Identcode ordering system

Dulcodes UV-Desinfektionsanlage

 

 

Identcode ordering system

Please enter the identcode on the device label into the grey box below.

S 2 C a

S i g m a C o n t ro l Ty p e ( S 2 C a )

HM

Power end, diaphragm

 

 

Pump typ: (figures 1+2 =back pressure [bar],figures 3-5 =feed rate [l/h])

 

16050

16 bar;

60 l/h

 

16090

16 bar;

95 l/h

 

16130

16 bar; 136 l/h

 

12050*

10 bar;

60 l/h

 

12090*

10 bar;

95 l/h

 

12130*

10 bar; 136 l/h

 

07120

7 bar; 148 l/h

 

07220

7 bar; 232 l/h

 

04350

4 bar; 350 l/h * for SST versions, max. 12 bar

 

Liquid end materials:

PV

PVDF

SS

Stainless steel

Seal material:

TPTFE seal

Displacement element:

0Standard diaphragm

1Double diaphragm with rupture indicator incorporating “Pump stopping” function

2 Double diaphragm with rupture indicator incorporating “Pump alarm” function

Liquid end version:

0No springs

1With 2 valve springs,Hastelloy C,0.1 bar

4With relief valve,Viton® seal,no valve spring

5 With relief valve,Viton® seal,with valve spring

Hydraulic connection:

0Standard threaded connector (according to technical data)

1 Union nut and PVC insert

2 Union nut and PP insert

3 Union nut and PVDF insert

4 Union nut and stainless steel insert

7 Union nut and PVDF hose nozzle

8 Union nut and stainless steel hose nozzle

Version:

0With ProMinent® logo

1Without ProMinent® logo

Electrical power supply:

U1 ph 100-230 V ±10 %, 50/60 Hz

Cable and plug:

A2 m European

B 2 m Swiss

C 2 m Australian

D 2 m USA

 

Relays:

0

No relay

1

With fault indicating relay (N/C)

3

With fault indicating relay (N/O)

4

As 1 with pacing relay

5

As 3 with pacing relay

F

Power relay N/C

G

Power relay N/O

 

Control variant:

0

Manual + external with pulse control

1

Manual + external + pulse control

 

+ analogue

4

As 0 + process-timer

5

As 1 + process-timer

P

PROFIBUS®

 

 

 

 

Access code:

 

0

No access code

 

1

With access code

 

 

 

 

 

 

Metering monitor:

 

 

 

 

0

Input with pulse evaluation

 

 

 

 

1

Input with permanent contact

 

 

 

 

 

 

evaluation

 

 

 

 

 

 

 

 

Stroke length

 

 

 

 

 

 

 

 

adjustment:

 

 

 

 

 

 

0

Manual

 

 

 

 

 

 

C

Manual + calibration

 

 

 

 

 

 

 

 

 

S2Ca

___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___

 

 

Viton® is a registered trademark of DuPont Dow Elastomers.

Page 10

ProMinent®

Image 10
Contents Operating Instructions Control elements and key functions Control elements overviewOperating-/Settings Diagram Continuous DisplayPrevious Analog ActivatedfunctionImprint Dulcodes UV-Desinfektionsanlage ImprintDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage Identcode ordering system B a G m a B a s i c Ty p e S 2 B aIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage Safety devices General notesDulcodes UV-Desinfektionsanlage Identification of pump type Product description S2Ba/S2CaDesign/Functional description Functional description, drive Stroke movement 75 % 30 %Metering capacity diagram HM50Hz MeteringcapacitydiagramS2BaS2CaHM Functional description, delivery unit Task Integrated overflow valve with bleeder functionDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Function Diaphragm rupture sensorUse for intended purpose/Use unintended purpose Design and function description see Fig3162-4 Pvdf Ptfe Technical data Technical data Sigma Capacity dataTemperature specifications Technical data S2CaAccuracy Dimension sheet Sigma/ 2 with stroke adjustment motor Dimensions Sigma/ 2 mmModel Connector Stroke actuator drive mechanism Stroke adjuster drive mechanismMotor data Electrical data, stroke sensor ÒSigmaÓSound intensity level Input voltage Mains frequency Power consumptionElectrical data, pacing relay ÒSigmaÓ Relay inputMaintenance Start-up/MaintenanceStart-up Replacement of wearing parts Maintenance intervalsGuideline on Valve Installation Function description, motors Features of the S2Ca metering pumpsFunction description, controller ÒFault indicating and pacing relayÓ option ÒFloat switchÓ functionOptional Òfault-indicating relayÓ or Òpower relayÓ LED indicator Operating indicator greenSockets, symbols and wiring diagram Hierarchy of operating modes, functions and fault statusesRelay type Power relay Wiring diagram Controller type 0 see identity code Technical data, external contactController type 1 see identity code Pump, Inside Block circuit diagram S2CaInputs OutputsCircuit examples universal signal cable By customer CableRetrofitting relays Not in Profibus version Delivery rangeControl elements Settings SetChange to settings mode Check adjustable valuesSelect operating mode Mode menu Settings for ÒmanualÓ operating mode Settings for operating mode SET menuSettings for ÒanalogueÓ operating mode Analg menu Set Straight lineLower band Upper band Alkali pump Acid pump Settings for ÒcontactÓ operating mode Contct menuLower/upper band Lower bandSet Settings for ÒbatchÓ operating mode Batch menu ÒMemoryÓ extension functionSettings for programmable functions SET menu Settings for ÒcalibrationÓ function Calib menuSetting code Code menu Settings for Òauxiliary frequencyÓ function AUX menuSettings for the ÒflowÓ function Flow menu Cancel total stroke number or total litres Clear windowOperating Manual operationTroubleshooting Remote controlError Messages Decommissioning and disposal Spare parts and accessories ProMinent 1011036For pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Stroke actuator wiring diagram Wiring diagram for stroke length adjuster