Operating / Troubleshooting

 

 

Batch size In “batch” operating mode:

The batch size can by changed from the “batch size/remaining litres” display.

The S3Ca returns to the original continuous display a few seconds after the batch size has been reset.

Priming The “priming” function is activated by pressing both arrow keys at the same time (in “Stroke rate” permanent display).

Cancel error Error messages are cancelled by pressing the P key briefly.

Continuous display

Stop/start pump

STOP

START

2

Change directly alterable values

Prime

P

P

Start batch (in "batch" operating mode only)

Cancel error

i

P 2 s

1

Settings

mode

Check adjustable values

1= Security lock (CODE 1)

2= Security lock (CODE 2)

8.2Remote control

Remote control of the S2Ca is possible via a control cable or PROFIBUS® (see Section 5.3 and Chapter 7, ”Supplementary instructions for ProMinent® gamma/ L and ProMinent® Sigma versions with PROFIBUS®“ as well as your documentation in the annex).

9Troubleshooting

WARNING

¥EX-pump only: metering pumps and their peripheral equipment must be serviced by specially trained or authorised personnel!

¥Always take suitable precautions when using hazardous chemicals!

¥Ensure the equipment is de-pressurised before working on the pump!

 

Pump primes despite completed stroke action and no venting

Cause

Crystalline deposits on the ball seat because valves have dried out.

Remedy

￿

Remove the suction sleeve from the chemical supply container and rinse out the liquid end

 

 

thoroughly.

 

￿

If still unsuccessful, dismantle valves and clean.

 

Fluid is seeping from the top plate

Cause

The liquid end is not sealed against the pump diaphragm.

Remedy

￿

Tighten screws in the liquid end.

 

￿

If unsuccessful, replace the diaphragm (see section 4.3).

ProMinent®

Page 53

Image 53
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Design/Functional description Functional description, drive Product description S2Ba/S2CaIdentification of pump type 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Design and functional description refer to Fig. No Integrated overflow valve with bleeder functionTask Product description S2Ba/S2Ca Use for intended purpose/Use unintended purpose Diaphragm rupture sensorFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataAccuracy Technical data S2CaTemperature specifications Model Connector Dimensions Sigma/ 2 mmDimension sheet Sigma/ 2 with stroke adjustment motor Motor data Stroke adjuster drive mechanismStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓElectrical data, pacing relay ÒSigmaÓ Input voltage Mains frequency Power consumptionSound intensity level Relay inputStart-up Start-up/MaintenanceMaintenance Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Function description, controller Features of the S2Ca metering pumpsFunction description, motors Optional Òfault-indicating relayÓ or Òpower relayÓ ÒFloat switchÓ functionÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Controller type 1 see identity code Technical data, external contactController type 0 see identity code Inputs Block circuit diagram S2CaPump, Inside OutputsBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsSelect operating mode Mode menu Check adjustable valuesChange to settings mode Settings for ÒanalogueÓ operating mode Analg menu Settings for operating mode SET menuSettings for ÒmanualÓ operating mode Straight line SetLower/upper band Settings for ÒcontactÓ operating mode Contct menuLower band Upper band Alkali pump Acid pump Lower bandSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuSettings for the ÒflowÓ function Flow menu Settings for Òauxiliary frequencyÓ function AUX menuSetting code Code menu Cancel total stroke number or total litres Clear windowManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram