Sigma S2Ba, S2Ca Motor data, Stroke actuator drive mechanism, Stroke adjuster drive mechanism

Page 28

Technical dataDulcodes UV-Desinfektionsanlage

 

 

3.1.4

Motor data

 

 

 

 

 

Electrical Data

 

 

 

Motors:

 

 

 

 

 

Identcode characteristic

 

 

 

 

 

 

 

3 ph IP 55

230

V/400 V

50 Hz

0.25 kW

1.62/0.94 A

S

3 ph IP 55

230

V/400 V

60 Hz

0.25 kW

1.42/0.82 A

S

 

 

 

 

 

 

 

1 ph AC

230

V

50/60 Hz

0.18 kW

1.7/1.5 A

M

1 ph AC

115 V

60 Hz

0.18 kW

3.3 A

N

 

 

 

 

 

 

 

3 ph EXe or EXde

230

V/400 V

50 Hz

0.18 kW

1.1/0.7 A

L

3 ph EXe or EXde

230

V/400 V

60 Hz

0.18 kW

1.1/0.6 A

P

 

 

 

 

 

 

 

3 ph IP 55

230

V/400 V

50/60 Hz

0.37 kW

......

R Version with external fan

 

 

 

 

 

 

1 PH 230 v; 50/60 Hz and PTC

1 ph IP 55

230

V

50/60 Hz

0.37 kW

.....

V Three phase motor with integrated

 

 

 

 

 

 

speed changer, (see chapter 11)

direction of rotation

Fig. 11

For more details you can request the motor specification sheets. Custom motors and/or custom motor flanges are available on request.

WARNING

¥EX-pump only: Drive motors must be secured by an appropriate motor protection switch. A motor protection approved for this application must be used for ExÒeÓ-motors. (Protection against heating due to overload)

¥EX-pump only: motors in EX-areas must be installed and checked by persons with Òrecognised skillsÓ!

¥EX-pump only: observe the operating manual supplied with the EX motor!

Fuse data

IMPORTANT

¥The motors are not fuse-protected. Fit a motor circuit breaker!

¥When connecting the motor, make sure that it rotates in the correct direction (see Fig. 11). Protection against accidental contact and moisture (IP)

Motor: IP 55 DIN EN 60034-5 (in accordance with DIN VDE 0470 Part 1, corresponds to EN 60529 and IEC 529).

External fan

Notes on the speed-controlled motor with separate fan and temperature monitoring may be found in the “General Operating Instructions ProMinent® Motor-Driven Metering Pumps and Hydraulic Accessories”.

3.1.5Stroke actuator drive mechanism

230 V ± 10 %

50/60 Hz

11.7 W

 

 

 

115 V ± 10 %

60 Hz

11.7 W

 

 

 

Cf. “Appendix” for terminal connection diagram.

3.1.6Stroke adjuster drive mechanism

230 V ± 10 %

50/60 Hz

6.5 W

 

 

 

115 V ± 10 %

60 Hz

6.5 W

 

 

 

Cf. “Appendix” for terminal connection diagram.

3.1.7Electrical data, stroke sensor ÒSigmaÓ

a)Reed contact (Identcode characteristic ÒStroke sensorÓ: 1)

Pin 1

(white)

=

4.5 V to 24 V, max. 10 mA

Pin 2

(brown)

=

OUT, open collector, 24 V, 20 mA

Pin 3

(green)

=

GND

Pulse width (low)

4 ms (depending on gearbox and power frequency)

Page 28

ProMinent®

Image 28
Contents Operating Instructions Control elements and key functions Control elements overviewOperating-/Settings Diagram Continuous DisplayPrevious Analog ActivatedfunctionImprint Dulcodes UV-Desinfektionsanlage ImprintDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage Identcode ordering system B a G m a B a s i c Ty p e S 2 B aIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage Safety devices General notesDulcodes UV-Desinfektionsanlage Identification of pump type Product description S2Ba/S2CaDesign/Functional description Functional description, drive Stroke movement 75 % 30 %Metering capacity diagram HM50Hz MeteringcapacitydiagramS2BaS2CaHM Functional description, delivery unit Task Integrated overflow valve with bleeder functionDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Diaphragm rupture sensor Use for intended purpose/Use unintended purposeFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Technical data Sigma Capacity dataTemperature specifications Technical data S2CaAccuracy Dimension sheet Sigma/ 2 with stroke adjustment motor Dimensions Sigma/ 2 mmModel Connector Stroke adjuster drive mechanism Motor dataStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓInput voltage Mains frequency Power consumption Electrical data, pacing relay ÒSigmaÓSound intensity level Relay inputMaintenance Start-up/MaintenanceStart-up Replacement of wearing parts Maintenance intervalsGuideline on Valve Installation Function description, motors Features of the S2Ca metering pumpsFunction description, controller ÒFloat switchÓ function Optional Òfault-indicating relayÓ or Òpower relayÓÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenSockets, symbols and wiring diagram Hierarchy of operating modes, functions and fault statusesRelay type Power relay Wiring diagram Controller type 0 see identity code Technical data, external contactController type 1 see identity code Block circuit diagram S2Ca InputsPump, Inside OutputsCircuit examples universal signal cable By customer CableRetrofitting relays Not in Profibus version Delivery rangeControl elements Settings SetChange to settings mode Check adjustable valuesSelect operating mode Mode menu Settings for ÒmanualÓ operating mode Settings for operating mode SET menuSettings for ÒanalogueÓ operating mode Analg menu Set Straight lineSettings for ÒcontactÓ operating mode Contct menu Lower/upper bandLower band Upper band Alkali pump Acid pump Lower bandSet Settings for ÒbatchÓ operating mode Batch menu ÒMemoryÓ extension functionSettings for programmable functions SET menu Settings for ÒcalibrationÓ function Calib menuSettings for Òauxiliary frequencyÓ function AUX menu Settings for the ÒflowÓ function Flow menuSetting code Code menu Cancel total stroke number or total litres Clear windowOperating Manual operationTroubleshooting Remote controlError Messages Decommissioning and disposal Spare parts and accessories ProMinent 1011036For pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Stroke actuator wiring diagram Wiring diagram for stroke length adjuster