S i g m a B a s i c Ty p e ( S 2 B a )

HM

Main drive, diaphragm

 

 

 

 

 

Pump type: (figures 1+2 = back pressure [bar], figures 3-5 = feed rate [l/h])

 

16050

16 bar;

50 l/h

 

16090

16 bar;

90 l/h

 

16130

16 bar; 130 l/h

 

12050*

10 bar;

48 l/h

 

12090*

10 bar;

86 l/h

 

12030*

10 bar; 125 l/h

 

07120

7 bar; 120 l/h

 

07220

7 bar; 220 l/h

 

04350

4 bar; 350 l/h * for SST versions, max. 12 bar

 

 

 

 

 

Liquid end materials:

PV

PVDF

SS

Stainless steel

Seal material:

TPTFE seal

Diaphragm:

0Standard diaphragm, PTFE version

1Double diaphragm with diaphragm rupture indicator (retro fit possible)

Liquid end version:

0No spring

1With 2 valve springs, Hastelloy C, 0.1 bar

4With pressure relief valve, Viton® seal, no valve spring

5 With pressure relief valve, Viton® seal, and valve spring

Hydraulic connection:

0Standard threaded connector (according to technical data)

1 Union nut and PVC insert

2 Union nut and PP insert

3 Union nut and PVDF insert

4 Union nut and stainless steel insert

7 Union nut and PVDF hose nozzle

8 Union nut and stainless steel hose nozzle

Version:

0With ProMinent® logo (standard)

1 Without ProMinent® logo

Electrical power supply:

S3 ph, 230 V/400 V 50/60 Hz, 0.18 kW M 1 ph, AC, 230 V/50/60 Hz, 0.18 kW

N 1 ph, AC 115 V 60 Hz, 0.18 kW

L 3 ph, 230 V/400 V, 50 Hz, (EExe, EExde)

P 3 ph, 230 V/400 V, 60 Hz, (EExe, EExde)

R 3 ph, variable speed motor, 230/400 V, 0.37 kW

V Variable speed motor with integrated speed control 1 pH, 230 V, 50/60 Hz

Z 1 ph, variable speed control set 1 ph, 230 V, 50/60 Hz

1 No motor, with B14 flange (Gr. 71 (DIN))

2 No motor, C 56 flange (NEMA)

3 No motor, B5 Gr. 63 (DIN)

4 No motor, B5, Gr. 70 (DIN)

Motor version:

0IP 55 (standard)

1Exe version (II 2G EExe II T3)

2Exde version (II 2G EExde IIC T4)

A ATEX type drive

 

Stroke sensor:

0

No stroke sensor (standard)

1

with stroke sensor (Hall sensor, no connection cable)

2

Pacing relay (reed relay)

3

Stroke sensor (Namur) intrinsically safe

 

 

 

 

Stroke length adjustment:

 

0

Manual (standard)

 

1

With stroke positioning motor, 230 V/50/60 Hz

 

2

With stroke positioning motor, 115 V/50/60 Hz

 

3

With stroke control motor,

 

 

 

 

0...20 mA 230 V/50/60 Hz

 

4

With stroke control motor

 

 

 

 

4...20 mA 230 V/50/60 Hz

 

5

With stroke control motor

 

 

 

 

0...20 mA 115 V/50/60 Hz

 

6

With stroke control motor

 

 

 

 

4...20 mA 115 V/50/60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S2Ba

___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___

 

 

Viton® is a registered trademark of DuPont Dow Elastomers.

®

®

Page 9

ProMinentProMinent

Image 9
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Product description S2Ba/S2Ca Identification of pump typeDesign/Functional description Functional description, drive 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Integrated overflow valve with bleeder function TaskDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Use for intended purpose/Use unintended purpose Diaphragm rupture sensorFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataTechnical data S2Ca Temperature specificationsAccuracy Dimensions Sigma/ 2 mm Dimension sheet Sigma/ 2 with stroke adjustment motorModel Connector Motor data Stroke adjuster drive mechanismStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓElectrical data, pacing relay ÒSigmaÓ Input voltage Mains frequency Power consumptionSound intensity level Relay inputStart-up/Maintenance MaintenanceStart-up Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Features of the S2Ca metering pumps Function description, motorsFunction description, controller Optional Òfault-indicating relayÓ or Òpower relayÓ ÒFloat switchÓ functionÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Technical data, external contact Controller type 0 see identity codeController type 1 see identity code Inputs Block circuit diagram S2CaPump, Inside OutputsBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsCheck adjustable values Change to settings modeSelect operating mode Mode menu Settings for operating mode SET menu Settings for ÒmanualÓ operating modeSettings for ÒanalogueÓ operating mode Analg menu Straight line SetLower/upper band Settings for ÒcontactÓ operating mode Contct menuLower band Upper band Alkali pump Acid pump Lower bandSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuSettings for the ÒflowÓ function Flow menu Settings for Òauxiliary frequencyÓ function AUX menuSetting code Code menu Cancel total stroke number or total litres Clear windowManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram