Spare parts and accessories

Dulcodes UV-Desinfektionsanlage

 

 

11 Spare parts and accessories

CAUTION

The assembly and installation of ProMinent® metering pumps with other-make parts that are not tested and recommended by ProMinent are not permitted and can lead to personal injury and damage to property for which no liability shall be accepted!

Spare parts

You will find the order numbers for the wearing parts in the exploded view drawings in the annex. If you require further parts, please order the “Spare parts list ProMinent® Sigma/ 2”.

Actuator for automatic stroke adjustment, setting time approx. 1 sec for 1% stroke length, feedback potentiometer 1k Ohm enclosure rating IP 54.

Adjuster comprising actuator and incorporating servo controller for stroke length adjustment via standard signal. Standard signal input 0/4-20 mA, corresponds to stroke length 0 – 100 %. Manual to automatic mode switch, switch for stroke length adjustment in manual mode, mechanical position display of 0/4-20 mA actual stroke length value output for remote display.

Variable speed motors with integrated speed changer (Identcode characteristic V)

Power supply 1 ph 230 V, 50/60 Hz, 0.37 kW

Optional external control via 0/4-20 mA

Speed controllers in metal casing (Identcode characteristic Z)

The speed controller kit comprises a speed changer and a 0.37 kW variable speed motor.

Float switches

2-stage, with 2 m connection cable

Alarm relays

For signalling faults

Alarm and pacing relays

For cyclic timing of other devices and for signalling faults.

Control cables

Universal control cable 5-core/2.5 and 10 m

External contact cable 2-core/2.5 and 10 m

Foot valves

With intake filter and non-return ball for connection at end of intake line.

Metering valves

With spring-loaded non-return ball for metering in open or closed systems and for mounting the metering line.

Backpressure valves

For exact metering at low operating pressure or as overflow safety valve.

Accumulators

For pulsation damping in long metering lines.

Metering monitors

For monitoring metering operations. After an adjustable number of non-acknowledged metering strokes, a fault is indicated and the metering pump shut down.

Intake assemblies

With foot valve and float switch for expendable packing drums or metering tanks.

Metering tanks

From 35 to 1000 l capacity with lockable screw cover and necessary accessories.

Manual/electric stirrers

For mixing and preparing metering solutions.

Page 56

ProMinent®

Image 56
Contents Operating Instructions Control elements and key functions Control elements overviewOperating-/Settings Diagram Continuous DisplayPrevious Analog ActivatedfunctionImprint Dulcodes UV-Desinfektionsanlage ImprintDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage Identcode ordering system B a G m a B a s i c Ty p e S 2 B aIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage Safety devices General notesDulcodes UV-Desinfektionsanlage Design/Functional description Functional description, drive Product description S2Ba/S2CaIdentification of pump type Stroke movement 75 % 30 %Metering capacity diagram HM50Hz MeteringcapacitydiagramS2BaS2CaHM Functional description, delivery unit Design and functional description refer to Fig. No Integrated overflow valve with bleeder functionTask Product description S2Ba/S2Ca Diaphragm rupture sensor Use for intended purpose/Use unintended purposeFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Technical data Sigma Capacity dataAccuracy Technical data S2CaTemperature specifications Model Connector Dimensions Sigma/ 2 mmDimension sheet Sigma/ 2 with stroke adjustment motor Stroke adjuster drive mechanism Motor dataStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓInput voltage Mains frequency Power consumption Electrical data, pacing relay ÒSigmaÓSound intensity level Relay inputStart-up Start-up/MaintenanceMaintenance Replacement of wearing parts Maintenance intervalsGuideline on Valve Installation Function description, controller Features of the S2Ca metering pumpsFunction description, motors ÒFloat switchÓ function Optional Òfault-indicating relayÓ or Òpower relayÓÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenSockets, symbols and wiring diagram Hierarchy of operating modes, functions and fault statusesRelay type Power relay Wiring diagram Controller type 1 see identity code Technical data, external contactController type 0 see identity code Block circuit diagram S2Ca InputsPump, Inside OutputsCircuit examples universal signal cable By customer CableRetrofitting relays Not in Profibus version Delivery rangeControl elements Settings SetSelect operating mode Mode menu Check adjustable valuesChange to settings mode Settings for ÒanalogueÓ operating mode Analg menu Settings for operating mode SET menuSettings for ÒmanualÓ operating mode Set Straight lineSettings for ÒcontactÓ operating mode Contct menu Lower/upper bandLower band Upper band Alkali pump Acid pump Lower bandSet Settings for ÒbatchÓ operating mode Batch menu ÒMemoryÓ extension functionSettings for programmable functions SET menu Settings for ÒcalibrationÓ function Calib menuSettings for Òauxiliary frequencyÓ function AUX menu Settings for the ÒflowÓ function Flow menuSetting code Code menu Cancel total stroke number or total litres Clear windowOperating Manual operationTroubleshooting Remote controlError Messages Decommissioning and disposal Spare parts and accessories ProMinent 1011036For pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Stroke actuator wiring diagram Wiring diagram for stroke length adjuster