Sigma S2Ca, S2Ba warranty ProMinent, 1011036

Page 57

Dulcodes UV-Desinfektionsanlage

Motor data sheet

 

 

Motor Datenblatt / Motor data sheet / Fiche technique pour moteur

Bestell Nr.

1011036

Hersteller

ATB

 

order no. / no. de commande

 

producer / producteur

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor-Typ

AF 63/4C-7

 

Leistungsfaktor

0,66

 

 

motor type

 

 

power factor

 

 

 

type du moteur

 

 

facteur de puissance

 

 

 

 

 

 

 

 

 

 

Maschinenart

3-Ph. Motor

 

Wirkungsgrad

88 %

 

 

type of machine

 

 

efficiency

 

 

 

désignation

 

 

rendement

 

 

 

 

 

 

 

 

 

 

Schutzart

IP55

 

Bemessungsfrequenz

50 Hz

 

degree of protection

 

 

rated frequency

 

 

 

degré de protection

 

 

fréquence nominale

 

 

 

 

 

 

 

 

 

 

Bauform

IMB5

 

Bemessungsdrehzahl

1370

 

U/min

mounting

 

 

rated speed

 

 

rpm

construction

 

 

vitesse nominale

 

 

t/mn

 

 

 

 

 

 

 

Bemessungsleistung

0,25 kW

 

WŠrmeklasse

F

 

rated output

 

 

temperature class

 

 

 

puissance nominale

 

 

class d’isolement

 

 

 

 

 

 

 

 

 

 

Bemessungsspannung

￿ /

 

Anzugsstrom

3,2

 

fach

rated voltage

400/230 V

 

starting current

 

 

fold

tension nominale

 

 

courant de démarrage

 

 

fois

 

 

 

 

 

 

 

Bemessungsstrom

0,94/1,62 A

 

Anzugsmoment

2,1

 

fach

rated current

 

 

starting torque

 

 

fold

courant nominale

 

 

couple de démarrge

 

 

fois

 

 

 

 

 

 

 

GeprŸft nach

DIN EN 60034

 

Kippmoment

2,3

 

fach

tested in acc. with

 

 

pull-out torque

 

 

fold

contrôlé selon

 

 

couple de décrochage

 

 

fois

 

 

 

 

 

 

 

PTB Nr.

ohne EX-Schutz

 

Umgebungstemperatur

max. 40 °C

 

 

without EX-protection

 

ambient temperature

 

 

 

 

 

 

température ambiante

 

 

 

 

 

 

 

 

 

 

 

 

 

Schaltung

￿ /

 

 

 

 

connection

 

 

 

 

 

 

branchement

 

 

 

 

 

 

 

 

 

 

Anmerkung

400/230 V

 

 

 

 

 

comments

380-420/220-240 V (50 Hz)

 

 

 

 

 

observation

 

 

 

 

 

 

ProMinent

Pumpentyp

S2Ca HM _ _ T _ _ _ _ U _ _ _ _ _ _

ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany

Nr./No. MD - 1011036

Datum/Date 28.02.2002

Motor datasheets are available for further information.

Special motors and special motor flanges are possible on request.

ProMinent®

Page 57

Image 57
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Product description S2Ba/S2Ca Identification of pump typeDesign/Functional description Functional description, drive 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Integrated overflow valve with bleeder function TaskDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Use for intended purpose/Use unintended purpose Diaphragm rupture sensorFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataTechnical data S2Ca Temperature specificationsAccuracy Dimensions Sigma/ 2 mm Dimension sheet Sigma/ 2 with stroke adjustment motorModel Connector Motor data Stroke adjuster drive mechanismStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓElectrical data, pacing relay ÒSigmaÓ Input voltage Mains frequency Power consumptionSound intensity level Relay inputStart-up/Maintenance MaintenanceStart-up Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Features of the S2Ca metering pumps Function description, motorsFunction description, controller Optional Òfault-indicating relayÓ or Òpower relayÓ ÒFloat switchÓ functionÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Technical data, external contact Controller type 0 see identity codeController type 1 see identity code Inputs Block circuit diagram S2CaPump, Inside OutputsBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsCheck adjustable values Change to settings modeSelect operating mode Mode menu Settings for operating mode SET menu Settings for ÒmanualÓ operating modeSettings for ÒanalogueÓ operating mode Analg menu Straight line SetLower/upper band Settings for ÒcontactÓ operating mode Contct menuLower band Upper band Alkali pump Acid pump Lower bandSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuSettings for the ÒflowÓ function Flow menu Settings for Òauxiliary frequencyÓ function AUX menuSetting code Code menu Cancel total stroke number or total litres Clear windowManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram