Sigma S2Ca, S2Ba warranty Settings

Page 43

Dulcodes UV-Desinfektionsanlage

Settings

 

 

Confirm entries

Exit menu option without confirming

7Settings

NOTE

¥Open out the fold-out page following the title page fully! There you will find the overviews Òcontrol elements and key functionsÓ and Òoperating settings diagramÓ.

¥If no keys are pressed within a period of 1 minute, the S2Ca will return to a continuous display.

Basic information for setting up the S2Ca

= Settings option

= flashes

Set ￿￿￿￿￿

P

Set ￿￿

P

P 3 s

 

P 3 s

 

continuous

 

 

 

display

 

 

 

Press the P key briefly;

you will automatically move to the next menu option or to a continuous display.

Press the P key for 3 s:

 

The entry￿￿￿￿is cancelled and you will￿￿￿￿return to a continuous display.￿￿￿￿

￿￿￿￿

i 2x

i 1x

P

Incremental change

 

of a value

Press the i key 1x;

 

you can toggle between altering the digits of a value (“change individual digits” = standard) or

 

incremental alteration of a value (“change a figure”).

Change adjustable values

Press UP or DOWN arrow key;

 

The flashing digit or figure will start to increase or decrease incrementally.

Confirm adjustable values

For “change individual digits”: confirm each digit using the P key. When the last digit has been

 

confirmed you will automatically move to the next menu option or to a continuous display.

 

For “change a figure”; press the P key 1x; you will simultaneously move to the next menu option

 

or to a continuous display.

Correct wrongly set digits

Press the i key 2x;

 

you will go back to the first digit.

ProMinent®

Page 43

Image 43
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Identification of pump type Product description S2Ba/S2CaDesign/Functional description Functional description, drive 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Task Integrated overflow valve with bleeder functionDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Design and function description see Fig Diaphragm rupture sensorUse for intended purpose/Use unintended purpose Function3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataTemperature specifications Technical data S2CaAccuracy Dimension sheet Sigma/ 2 with stroke adjustment motor Dimensions Sigma/ 2 mmModel Connector Electrical data, stroke sensor ÒSigmaÓ Stroke adjuster drive mechanismMotor data Stroke actuator drive mechanismRelay input Input voltage Mains frequency Power consumptionElectrical data, pacing relay ÒSigmaÓ Sound intensity levelMaintenance Start-up/MaintenanceStart-up Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Function description, motors Features of the S2Ca metering pumpsFunction description, controller LED indicator Operating indicator green ÒFloat switchÓ functionOptional Òfault-indicating relayÓ or Òpower relayÓ ÒFault indicating and pacing relayÓ optionHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Controller type 0 see identity code Technical data, external contactController type 1 see identity code Outputs Block circuit diagram S2CaInputs Pump, InsideBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsChange to settings mode Check adjustable valuesSelect operating mode Mode menu Settings for ÒmanualÓ operating mode Settings for operating mode SET menuSettings for ÒanalogueÓ operating mode Analg menu Straight line SetLower band Settings for ÒcontactÓ operating mode Contct menuLower/upper band Lower band Upper band Alkali pump Acid pumpSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuCancel total stroke number or total litres Clear window Settings for Òauxiliary frequencyÓ function AUX menuSettings for the ÒflowÓ function Flow menu Setting code Code menuManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram