Troubleshooting / Decommissioning and disposal

 

 

 

Red LED display is lit, ÒErrorÓ appears in the display and ÒFANÓ is flashing

Cause

Fault related to fan in pump housing.

Remedy

￿ Check fan and replace if necessary.

 

￿ Press the P key (reset function).

 

Red LED display is lit, ÒErrorÓ appears in the display and ÒSYSTEMÓ is flashing

Cause

Controller fault.

Remedy

￿ Disconnect the pump from the mains and reconnect.

 

If the error message continues, send the pump back to ProMinent.

 

Red LED lights up, ÒErrorÓ appears in the display and ÒMenuÓ flashes.

Cause

Stroke buffer full

Remedy

￿ Rectify fault

 

￿ Press P key (Make a note of what effect this has on your process).

 

All other Errors

 

Please contact your ProMinent branch or representative!

 

Fault Signals

 

Yellow LED display is lit

Cause

Liquid level in chemical storage tank has reached “liquid level low, stage 1”.

Remedy

￿ Fill chemical storage tank.

 

Yellow LED Display is lit and ÒcalibÓ flashes

Cause

The pump is calibrated and the stroke length deviates by more than ±10 % from the value at

 

the time of calibration.

Remedy

￿ Reset the stroke length or calibrate the pump again to the desired stroke length.

 

10

Decommissioning and disposal

Decommissioning

 

 

 

WARNING

 

¥ EX-pump only: metering pumps and their periphery must be maintained or decommissioned by qualified or authorised personnel!

¥ For all metering pumps for metering inflammable media applies: Starting up and emptying only supervised by a competent person.

¥ When decommissioning the pump, ensure that all dirt and chemicals are cleaned from the housing and particularly the liquid end.

¥ Always take suitable precautions when using hazardous chemicals! ¥ Ensure that the equipment is de-pressurised!

￿ Disconnect the pump from the mains.

￿ Empty the liquid end by placing the pump on its head and allowing the chemical to drain out.

￿ Rinse the liquid end with a suitable material, thoroughly rinse the liquid end after use with hazardous materials!

If decommissioning is only temporary, maintain the correct storage conditions:

Storage temperature: -10 to +50 °C

Air humidity:

< 92 % relative humidity

Disposal

WARNING

Spring under tension!

Take particular care when disassembling the pump as the return spring (Item 5, Chapter 2.2) is under considerable mechanical tension!

IMPORTANT

Observe your locally applicable regulations (particularly with regard to electronic scrap and gear oil)!

ProMinent®

Page 55

Image 55
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Identification of pump type Product description S2Ba/S2CaDesign/Functional description Functional description, drive 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Task Integrated overflow valve with bleeder functionDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Design and function description see Fig Diaphragm rupture sensorUse for intended purpose/Use unintended purpose Function3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataTemperature specifications Technical data S2CaAccuracy Dimension sheet Sigma/ 2 with stroke adjustment motor Dimensions Sigma/ 2 mmModel Connector Electrical data, stroke sensor ÒSigmaÓ Stroke adjuster drive mechanismMotor data Stroke actuator drive mechanismRelay input Input voltage Mains frequency Power consumptionElectrical data, pacing relay ÒSigmaÓ Sound intensity levelMaintenance Start-up/MaintenanceStart-up Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Function description, motors Features of the S2Ca metering pumpsFunction description, controller LED indicator Operating indicator green ÒFloat switchÓ functionOptional Òfault-indicating relayÓ or Òpower relayÓ ÒFault indicating and pacing relayÓ optionHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Controller type 0 see identity code Technical data, external contactController type 1 see identity code Outputs Block circuit diagram S2CaInputs Pump, InsideBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsChange to settings mode Check adjustable valuesSelect operating mode Mode menu Settings for ÒmanualÓ operating mode Settings for operating mode SET menuSettings for ÒanalogueÓ operating mode Analg menu Straight line SetLower band Settings for ÒcontactÓ operating mode Contct menuLower/upper band Lower band Upper band Alkali pump Acid pumpSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuCancel total stroke number or total litres Clear window Settings for Òauxiliary frequencyÓ function AUX menuSettings for the ÒflowÓ function Flow menu Setting code Code menuManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram