Dulcodes | Product description S2Ba/S2Ca |
|
|
2Product description S2Ba/S2Ca
WARNING
Use for intended purpose
¥The pump is designed as a liquid medium metering pump; it serves the purpose of metering liquid medium within the specified line system!
¥In
¥From July 1st, 2003 on, only pumps with the corresponding marking according to
¥Operate the pump only within the conditions described in the technical data!
¥General restrictions with regard to viscosity limits, chemical resistance and density must be observed (refer to ProMinent¨ chemical resistance list (catalogue or homepage))!
¥All other applications or conversion are prohibited!
¥The pump is not designed to meter gaseous media as well as solids.
¥For pumps without EX protection: The pump is not suitable for metering combustible liquids!
¥Pumps may never be operated in
¥Only specifically trained and authorized personnel are permitted to operate the pump!
2.1Identification of pump type
Fig. 1
The identity code and serial number are given in addition to the standard technical specifications. These two numbers must always be quoted when making any enquiries as they enable distinct identification of the type of metering pump.
2.2Design/Functional description
2.2.1Functional description, drive
The ProMinent® Sigma/ 2
(3)to the push rod (4) connected to fork (8) and converted into oscillatory movement. Return spring (5) presses the fork with push rod positively against the eccentric roller thus producing the return stroke. The stroke is adjusted by means of stroke adjustment knob (6) and spindle (7) by limiting the return stroke. Stroke movement is transmitted directly to the displacement diaphragm. Interacting with the valves, this diaphragm produces the overpressure and vacuum in the liquid end necessary for delivery. Flow is pulsating.
In the basic type, the electric motor is normally a
ProMinent® | Page 15 |