Product description S2Ba/S2Ca | Dulcodes |
|
|
Blue | - |
|
|
Brown | + |
|
|
Material in contact with metered medium |
| |
Liquid end: | Parts of diaphragm failure monitor in contact with medium | |
|
|
|
| Lens, seals | Intermediate disc Item 147, |
| Item 148, 156, 159 | intermediate bush Item 150 |
PVDF | PTFE | PVDF |
Stainless steel 1.4571 | PTFE | PVDF |
Electrical data for the diaphragm breakage sensor |
| |||
a) Switch contact |
|
|
|
|
30 V DC/1 A | or | 125 V AC/0.6 A | or | 250 V AC/0.3 A |
The diaphragm sensor is a N/C relay.
IMPORTANT
Before commencing operation, install the provided diaphragm breakage sensor together with the gasket (Item159) and make the electrical connections.
NOTE
¥For safety reasons it is advisable to connect a safe low voltage (e.g. EN
¥The cable priority is arbitrary.
b) Namur sensor, intrinsically
Power consumption:
Active surface, uncovered > 3 mA Active surface, covered < 2 mA
Rated switching distance: 1.5 mm
The monitor/feeder must be capable of evaluating current changes in order to indicate diaphragm rupture!
WARNING
¥
¥
IMPORTANT
¥Before commencing operation, install the provided diaphragm breakage sensor together with the gasket (Item159) and make the electrical connections.
¥For pump without EX protection: For safety reasons it is advisable to connect a safe low voltage (e.g. EN
Page 24 | ProMinent® |