Sigma S2Ca, S2Ba Settings for ÒcontactÓ operating mode Contct menu, Lower/upper band, Lower band

Page 47

Dulcodes UV-Desinfektionsanlage

Settings

 

 

Lower/upper band:

This processing mode allows you to control a pump via an electrical signal as shown in the diagrams below.

Lower band

Upper band

e.g. Alkali pump

e.g. acid pump

Fmax

F1

F2

P1

P2

Fmax

F2

F1

P2

P1

0

I 1

I 2

20 I [mA]

0

I 1

I 2 20 I [mA]

Fig. 20

 

 

Fig. 21

 

 

Lower band:

 

 

 

 

 

The symbol

 

appears in the LCD display. The S2Ca will operate below I1 at F1.

Above I2, the S2Ca ceases to operate. Between I1 and I2 the stroke rate is between F1 and F2, proportional to the signal current.

Upper band:

 

The signal

appears in the LCD display. The S2Ca will cease to operate below I1.

Above I2, the S2Ca will operate at F2. Between I1 and I2 the stroke rate between is F1 and F2, proportional to the signal current.

The smallest processable difference between I1 and I2 is 4 mA.

Error processing In the “ER” (error) menu option you can activate an error processing function for the “curve” mode. An error message appears for signals below 3.8 mA and the S2Ca stops.

7.4.3Settings for ÒcontactÓ operating mode (CONTCT menu)

In addition to those settings menus described in 7.5, there is an additional CONTCT in the overall SET menu for the “contact” operating mode.

The operating mode “contact” allows you to activate a single stroke or a series of strokes. The strokes can be activated by a pulse or via the “external control” terminal. This operating mode is intended to transfer input pulses into a reduction (fraction) or small increase in strokes.

IMPORTANT

The factor resets to Ò1Ó if you change to a different operating mode.tity cod

ProMinent®

Page 47

Image 47
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Design/Functional description Functional description, drive Product description S2Ba/S2CaIdentification of pump type 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Design and functional description refer to Fig. No Integrated overflow valve with bleeder functionTask Product description S2Ba/S2Ca Design and function description see Fig Diaphragm rupture sensorUse for intended purpose/Use unintended purpose Function3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataAccuracy Technical data S2CaTemperature specifications Model Connector Dimensions Sigma/ 2 mmDimension sheet Sigma/ 2 with stroke adjustment motor Electrical data, stroke sensor ÒSigmaÓ Stroke adjuster drive mechanismMotor data Stroke actuator drive mechanismRelay input Input voltage Mains frequency Power consumptionElectrical data, pacing relay ÒSigmaÓ Sound intensity levelStart-up Start-up/MaintenanceMaintenance Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Function description, controller Features of the S2Ca metering pumpsFunction description, motors LED indicator Operating indicator green ÒFloat switchÓ functionOptional Òfault-indicating relayÓ or Òpower relayÓ ÒFault indicating and pacing relayÓ optionHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Controller type 1 see identity code Technical data, external contactController type 0 see identity code Outputs Block circuit diagram S2CaInputs Pump, InsideBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsSelect operating mode Mode menu Check adjustable valuesChange to settings mode Settings for ÒanalogueÓ operating mode Analg menu Settings for operating mode SET menuSettings for ÒmanualÓ operating mode Straight line SetLower band Settings for ÒcontactÓ operating mode Contct menuLower/upper band Lower band Upper band Alkali pump Acid pumpSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuCancel total stroke number or total litres Clear window Settings for Òauxiliary frequencyÓ function AUX menuSettings for the ÒflowÓ function Flow menu Setting code Code menuManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram