Sigma S2Ca, S2Ba Settings for ÒbatchÓ operating mode Batch menu, ÒMemoryÓ extension function

Page 49

Dulcodes UV-Desinfektionsanlage

Settings

 

 

NOTE

If a remainder occurs when the factor is processed, the S2Ca counts up the remainder values. When the sum reaches or exceeds Ò1Ó the S2Ca will activate a stroke. This ensures that the stroke number corresponds exactly to the factor throughout the dosing operation.

The number of input pulses which have not been processed are stored by the S2Ca in the stroke memory. The stroke buffer is limited to the batch size when memory is not activated (- with “Memory” at 65535 stokes). You can delete it by switching to a different operating mode.

You can optimally adapt the S2Ca to the respective process, e.g. in connection with contact water meters.

ÒMemoryÓ extension function

The “memory” extension function can be optionally activated (“mem” appears in the LCD display). When “Memory” is activated the S2Ca adds any strokes which could not be carried out up to the maximum capacity of the stroke buffer – 65535 strokes. If this maximum capacity is exceeded the pump will register a fault.

7.4.4Settings for ÒbatchÓ operating mode (BATCH menu)

In addition to those settings menus described in 7.5, there is an additional BATCH menu in the overall SET menu for the “batch” operating mode.

P

P

Mem

Batch

P

Mem

￿￿￿￿￿Batch

P

 

 

 

 

 

 

￿￿￿

Set ￿￿￿￿￿

Set

￿￿

 

Set

L

 

Continuous

 

 

 

 

 

 

 

display

 

 

 

 

 

 

 

The “batch” operating mode is a variant of the “contact” operating mode (see 7.4.3).

You can pre-select a stroke number (no breaks, whole numbers only from 1 to 65535) as well as a feed quantity (batch). To switch between entries for “stroke number” and “feed quantity” press the i key 1x in the corresponding menu option (see also overview “operating/settings diagram”, fold-out page).

The “batch” operating mode is intended for large dosing quantities.

Metering can be actuated by pressing the P-key or via a pulse from the “external control socket”.

The number of input pulses which have not been processed are stored by the S2Ca in the stroke memory. The stroke buffer is limited to the batch size when memory is not activated (- with “Memory” at 65535 stokes). You can delete it by switching to a different operating mode.

ÒMemoryÓ extension function

The “memory” extension function can be optionally activated (“mem” appears in the LCD display). When “Memory” is activated the S2Ca adds any strokes which could not be carried out up to the maximum capacity of the stroke buffer – 65535 strokes. If this maximum capacity is exceeded the pump will register a fault.

ProMinent®

Page 49

Image 49
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Identification of pump type Product description S2Ba/S2CaDesign/Functional description Functional description, drive 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Task Integrated overflow valve with bleeder functionDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Use for intended purpose/Use unintended purpose Diaphragm rupture sensorFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataTemperature specifications Technical data S2CaAccuracy Dimension sheet Sigma/ 2 with stroke adjustment motor Dimensions Sigma/ 2 mmModel Connector Motor data Stroke adjuster drive mechanismStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓElectrical data, pacing relay ÒSigmaÓ Input voltage Mains frequency Power consumptionSound intensity level Relay inputMaintenance Start-up/MaintenanceStart-up Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Function description, motors Features of the S2Ca metering pumpsFunction description, controller Optional Òfault-indicating relayÓ or Òpower relayÓ ÒFloat switchÓ functionÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Controller type 0 see identity code Technical data, external contactController type 1 see identity code Inputs Block circuit diagram S2CaPump, Inside OutputsBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsChange to settings mode Check adjustable valuesSelect operating mode Mode menu Settings for ÒmanualÓ operating mode Settings for operating mode SET menuSettings for ÒanalogueÓ operating mode Analg menu Straight line SetLower/upper band Settings for ÒcontactÓ operating mode Contct menuLower band Upper band Alkali pump Acid pump Lower bandSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuSettings for the ÒflowÓ function Flow menu Settings for Òauxiliary frequencyÓ function AUX menuSetting code Code menu Cancel total stroke number or total litres Clear windowManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram