Sigma S2Ca, S2Ba warranty Order No

Page 61

Dulcodes UV-Desinfektionsanlage

Exploded diagrams of liquid ends

 

 

Delivery unit Sigma/ 2 350-DN 25 SST for identity code types: S2Ba/S2Ca 04350, 07120, 07220

Delivery unit Sigma/ 2 130-DN 15 SST for identity code types: S2Ba/S2Ca 12050, 12090, 12130

Spring **

Ball *

Valve assy DN 10/SST* Order No. 809459

 

 

Ball seat *

Diaphragm FM 050

Order No 1010279

 

Diaphragm FM 065

Order No. 1010282

Valve assy DN 10/SST* Order No. 809459

Spare parts kit FM 350

SST without valve

Order No. 740327

Spare parts kit FM 350

SST with 2 valves

Order No. 740329

Spare parts kit FM 130

SST without valve

Order No. 740326

Spare parts kit FM 130

SST with 2 valves

Order No. 740328

* The listed items are constituent parts of the spare parts kit.

**Special accessories (not included in spare parts kit). Subject to technical modifications.

Fig. 25

61_05-104_01_01-03_2_norm

ProMinent®

Page 61

Image 61
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Identification of pump type Product description S2Ba/S2CaDesign/Functional description Functional description, drive 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Task Integrated overflow valve with bleeder functionDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Use for intended purpose/Use unintended purpose Diaphragm rupture sensorFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataTemperature specifications Technical data S2CaAccuracy Dimension sheet Sigma/ 2 with stroke adjustment motor Dimensions Sigma/ 2 mmModel Connector Motor data Stroke adjuster drive mechanismStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓElectrical data, pacing relay ÒSigmaÓ Input voltage Mains frequency Power consumptionSound intensity level Relay inputMaintenance Start-up/MaintenanceStart-up Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Function description, motors Features of the S2Ca metering pumpsFunction description, controller Optional Òfault-indicating relayÓ or Òpower relayÓ ÒFloat switchÓ functionÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Controller type 0 see identity code Technical data, external contactController type 1 see identity code Inputs Block circuit diagram S2CaPump, Inside OutputsBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsChange to settings mode Check adjustable valuesSelect operating mode Mode menu Settings for ÒmanualÓ operating mode Settings for operating mode SET menuSettings for ÒanalogueÓ operating mode Analg menu Straight line SetLower/upper band Settings for ÒcontactÓ operating mode Contct menuLower band Upper band Alkali pump Acid pump Lower bandSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuSettings for the ÒflowÓ function Flow menu Settings for Òauxiliary frequencyÓ function AUX menuSetting code Code menu Cancel total stroke number or total litres Clear windowManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram