Dulcodes | Technical data |
|
|
3Technical data
3.1Technical data Sigma/ 2
3.1.1Capacity data
Technical data S2Ba at 50 Hz operation
|
| Feed rate at |
| Max. | Suction | Admissible | Connection | Shipping |
|
| maximum |
| stroke | lift | priming | suction / | weight |
|
| back pressure |
| rate |
| pressure | discharge |
|
|
|
|
|
|
| suction side | side |
|
|
|
|
|
|
|
|
|
|
Pump type Sigma/ | bar | l/h | ml/stroke | strokes/min. | m Ws | bar | G - DN | kg |
|
|
|
|
|
|
|
|
|
12050 PVT | 10 | 50 | 11.4 | 73 | 7 | 3 | 15 | |
12050 SST | 12 | 48 | 11.4 | 73 | 7 | 3 | 20 | |
|
|
|
|
|
|
|
|
|
16050 SST | 16 | 48 | 11.4 | 73 | 7 | 3 | 20 | |
12090 PVT | 10 | 90 | 11.4 | 132 | 7 | 3 | 15 | |
|
|
|
|
|
|
|
|
|
12090 SST | 12 | 86 | 11.4 | 132 | 7 | 3 | 20 | |
16090 SST | 16 | 86 | 11.4 | 132 | 7 | 3 | 20 | |
|
|
|
|
|
|
|
|
|
12130 PVT | 10 | 130 | 10.9 | 198 | 7 | 3 | 15 | |
12130 SST | 12 | 125 | 10.9 | 198 | 7 | 3 | 20 | |
|
|
|
|
|
|
|
|
|
16130 SST | 16 | 125 | 10.9 | 198 | 7 | 3 | 20 | |
07120 PVT | 7 | 120 | 27.4 | 73 | 5 | 1 | 20* | 16 |
|
|
|
|
|
|
|
|
|
07120 SST | 7 | 120 | 27.4 | 73 | 5 | 1 | 20* | 24 |
07220 PVT | 7 | 220 | 27.7 | 132 | 5 | 1 | 20* | 16 |
|
|
|
|
|
|
|
|
|
07220 SST | 7 | 220 | 27.7 | 132 | 5 | 1 | 20* | 24 |
04350 PVT | 4 | 350 | 29.4 | 198 | 5 | 1 | 20* | 16 |
|
|
|
|
|
|
|
|
|
04350 SST | 4 | 350 | 29.4 | 198 | 5 | 1 | 20* | 24 |
|
|
|
|
|
|
|
|
|
All performance data applies to water at 20 °C.
The suction lift applies when the suction line and liquid end are full and correctly installed.
*Sigma types 07120, 07220 and 04350, the valves used in the liquid end are DN 25 (G11/2). Since DN 20 is usually adequate for this tubing (see Technical Data,
Technical data S2Ba at 60 Hz operation |
|
|
|
|
|
| ||
|
| Feed rate at |
| Max. | Suction | Admissible | Connection | Shipping |
|
|
| ||||||
|
| maximum |
| stroke | lift | priming | suction / | weight |
|
| back pressure |
| rate |
| pressure | discharge |
|
|
|
|
|
|
| suction side | side |
|
|
|
|
|
|
|
|
|
|
Pump type Sigma/ | bar | psi | I/h/gph | strokes/min. | m Ws | bar | G - DN | kg |
12050 PVT | 10 | 145 | 60/ 15.9 | 87 | 7 | 3 | 15 | |
12050 SST | 12 | 174 | 57/ 15.2 | 87 | 7 | 3 | 20 | |
|
|
|
|
|
|
|
|
|
16050 SST | 16 | 232 | 57/ 15.2 | 87 | 7 | 3 | 20 | |
12090 PVT | 10 | 145 | 108/ 28.5 | 156 | 7 | 3 | 15 | |
|
|
|
|
|
|
|
|
|
12090 SST | 12 | 174 | 103/ 27 | 156 | 7 | 3 | 20 | |
16090 SST | 16 | 232 | 103/ 27 | 156 | 7 | 3 | 20 | |
|
|
|
|
|
|
|
|
|
12130 PVT | 10 | 145 | 156/ 41 | 232 | 7 | 3 | 15 | |
12130 SST | 12 | 174 | 150/ 39.6 | 232 | 7 | 3 | 20 | |
|
|
|
|
|
|
|
|
|
16130 SST | 16 | 232 | 150/ 39.6 | 232 | 7 | 3 | 20 | |
07120 PVT | 7 | 100 | 144/ 38 | 87 | 5 | 1 | 20* | 16 |
|
|
|
|
|
|
|
|
|
07120 SST | 7 | 100 | 144/ 38 | 87 | 5 | 1 | 20* | 24 |
07220 PVT | 7 | 100 | 264/ 69.7 | 156 | 5 | 1 | 20* | 16 |
|
|
|
|
|
|
|
|
|
07220 SST | 7 | 100 | 264/ 69.7 | 156 | 5 | 1 | 20* | 24 |
04350 PVT | 4 | 58 | 420/ 111 | 232 | 5 | 1 | 20* | 16 |
|
|
|
|
|
|
|
|
|
04350 SST | 4 | 58 | 420/ 111 | 232 | 5 | 1 | 20* | 24 |
|
|
|
|
|
|
|
|
|
All performance data applies to water at 20 °C.
The suction lift applies when the suction line and liquid end are full and correctly installed.
*Sigma types 07120, 07220 and 04350, the valves used in the liquid end are DN 25 (G11/2). Since DN 20 is usually adequate for this tubing (see Technical Data,
ProMinent® | Page 25 |