Sigma S2Ca, S2Ba warranty Technical data Sigma Capacity data

Page 25

Dulcodes UV-Desinfektionsanlage

Technical data

 

 

3Technical data

3.1Technical data Sigma/ 2

3.1.1Capacity data

Technical data S2Ba at 50 Hz operation

 

 

Feed rate at

 

Max.

Suction

Admissible

Connection

Shipping

 

 

maximum

 

stroke

lift

priming

suction /

weight

 

 

back pressure

 

rate

 

pressure

discharge

 

 

 

 

 

 

 

suction side

side

 

 

 

 

 

 

 

 

 

 

Pump type Sigma/

bar

l/h

ml/stroke

strokes/min.

m Ws

bar

G - DN

kg

 

 

 

 

 

 

 

 

 

12050 PVT

10

50

11.4

73

7

3

1"-15

15

12050 SST

12

48

11.4

73

7

3

1"-15

20

 

 

 

 

 

 

 

 

 

16050 SST

16

48

11.4

73

7

3

1"-15

20

12090 PVT

10

90

11.4

132

7

3

1"-15

15

 

 

 

 

 

 

 

 

 

12090 SST

12

86

11.4

132

7

3

1"-15

20

16090 SST

16

86

11.4

132

7

3

1"-15

20

 

 

 

 

 

 

 

 

 

12130 PVT

10

130

10.9

198

7

3

1"-15

15

12130 SST

12

125

10.9

198

7

3

1"-15

20

 

 

 

 

 

 

 

 

 

16130 SST

16

125

10.9

198

7

3

1"-15

20

07120 PVT

7

120

27.4

73

5

1

20*

16

 

 

 

 

 

 

 

 

 

07120 SST

7

120

27.4

73

5

1

20*

24

07220 PVT

7

220

27.7

132

5

1

20*

16

 

 

 

 

 

 

 

 

 

07220 SST

7

220

27.7

132

5

1

20*

24

04350 PVT

4

350

29.4

198

5

1

20*

16

 

 

 

 

 

 

 

 

 

04350 SST

4

350

29.4

198

5

1

20*

24

 

 

 

 

 

 

 

 

 

All performance data applies to water at 20 °C.

The suction lift applies when the suction line and liquid end are full and correctly installed.

*Sigma types 07120, 07220 and 04350, the valves used in the liquid end are DN 25 (G11/2). Since DN 20 is usually adequate for this tubing (see Technical Data, connection-suction/discharge side) the connector parts to be ordered by Identcode (e.g. washers) have already been reduced to DN 20, i.e. tubing and accessories can be DN 20.

Technical data S2Ba at 60 Hz operation

 

 

 

 

 

 

 

 

Feed rate at

 

Max.

Suction

Admissible

Connection

Shipping

 

 

 

 

 

maximum

 

stroke

lift

priming

suction /

weight

 

 

back pressure

 

rate

 

pressure

discharge

 

 

 

 

 

 

 

suction side

side

 

 

 

 

 

 

 

 

 

 

Pump type Sigma/

bar

psi

I/h/gph

strokes/min.

m Ws

bar

G - DN

kg

12050 PVT

10

145

60/ 15.9

87

7

3

1"-15

15

12050 SST

12

174

57/ 15.2

87

7

3

1"-15

20

 

 

 

 

 

 

 

 

 

16050 SST

16

232

57/ 15.2

87

7

3

1"-15

20

12090 PVT

10

145

108/ 28.5

156

7

3

1"-15

15

 

 

 

 

 

 

 

 

 

12090 SST

12

174

103/ 27

156

7

3

1"-15

20

16090 SST

16

232

103/ 27

156

7

3

1"-15

20

 

 

 

 

 

 

 

 

 

12130 PVT

10

145

156/ 41

232

7

3

1"-15

15

12130 SST

12

174

150/ 39.6

232

7

3

1"-15

20

 

 

 

 

 

 

 

 

 

16130 SST

16

232

150/ 39.6

232

7

3

1"-15

20

07120 PVT

7

100

144/ 38

87

5

1

20*

16

 

 

 

 

 

 

 

 

 

07120 SST

7

100

144/ 38

87

5

1

20*

24

07220 PVT

7

100

264/ 69.7

156

5

1

20*

16

 

 

 

 

 

 

 

 

 

07220 SST

7

100

264/ 69.7

156

5

1

20*

24

04350 PVT

4

58

420/ 111

232

5

1

20*

16

 

 

 

 

 

 

 

 

 

04350 SST

4

58

420/ 111

232

5

1

20*

24

 

 

 

 

 

 

 

 

 

All performance data applies to water at 20 °C.

The suction lift applies when the suction line and liquid end are full and correctly installed.

*Sigma types 07120, 07220 and 04350, the valves used in the liquid end are DN 25 (G11/2). Since DN 20 is usually adequate for this tubing (see Technical Data, connection-suction/discharge side) the connector parts to be ordered by Identcode (e.g. washers) have already been reduced to DN 20, i.e. tubing and accessories can be DN 20.

ProMinent®

Page 25

Image 25
Contents Operating Instructions Control elements overview Control elements and key functionsContinuous Display Operating-/Settings DiagramPrevious Activatedfunction AnalogImprint Imprint Dulcodes UV-DesinfektionsanlageDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage B a G m a B a s i c Ty p e S 2 B a Identcode ordering systemIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage General notes Safety devicesDulcodes UV-Desinfektionsanlage Identification of pump type Product description S2Ba/S2CaDesign/Functional description Functional description, drive 75 % 30 % Stroke movementHM50Hz MeteringcapacitydiagramS2Ba Metering capacity diagramS2CaHM Functional description, delivery unit Task Integrated overflow valve with bleeder functionDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Use for intended purpose/Use unintended purpose Diaphragm rupture sensorFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Sigma Capacity data Technical dataTemperature specifications Technical data S2CaAccuracy Dimension sheet Sigma/ 2 with stroke adjustment motor Dimensions Sigma/ 2 mmModel Connector Motor data Stroke adjuster drive mechanismStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓElectrical data, pacing relay ÒSigmaÓ Input voltage Mains frequency Power consumptionSound intensity level Relay inputMaintenance Start-up/MaintenanceStart-up Maintenance intervals Replacement of wearing partsGuideline on Valve Installation Function description, motors Features of the S2Ca metering pumpsFunction description, controller Optional Òfault-indicating relayÓ or Òpower relayÓ ÒFloat switchÓ functionÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenHierarchy of operating modes, functions and fault statuses Sockets, symbols and wiring diagramRelay type Power relay Wiring diagram Controller type 0 see identity code Technical data, external contactController type 1 see identity code Inputs Block circuit diagram S2CaPump, Inside OutputsBy customer Cable Circuit examples universal signal cableNot in Profibus version Delivery range Retrofitting relaysControl elements Set SettingsChange to settings mode Check adjustable valuesSelect operating mode Mode menu Settings for ÒmanualÓ operating mode Settings for operating mode SET menuSettings for ÒanalogueÓ operating mode Analg menu Straight line SetLower/upper band Settings for ÒcontactÓ operating mode Contct menuLower band Upper band Alkali pump Acid pump Lower bandSet ÒMemoryÓ extension function Settings for ÒbatchÓ operating mode Batch menuSettings for ÒcalibrationÓ function Calib menu Settings for programmable functions SET menuSettings for the ÒflowÓ function Flow menu Settings for Òauxiliary frequencyÓ function AUX menuSetting code Code menu Cancel total stroke number or total litres Clear windowManual operation OperatingRemote control TroubleshootingError Messages Decommissioning and disposal Spare parts and accessories 1011036 ProMinentFor pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Wiring diagram for stroke length adjuster Stroke actuator wiring diagram