Sigma S2Ba, S2Ca warranty Set

Page 48

Settings

Dulcodes UV-Desinfektionsanlage

 

 

In the “contact - identity code: external with external pulse control” you can enter the number

of pulses after which a stroke should be carried out. “Contact - identity code: external with external pulse control” is intended for small dosing quantities.

￿￿￿

Continuous display

P

Set ￿￿￿￿￿

P

Contact

Set ￿￿

 

 

Mem

P

￿￿￿Contact￿

Mem

Set

P

The number of strokes per pulse depends upon the factor, which you can enter. This allows you to vary to a certain extent the input pulses by a factor of 1.01 to 99.99 and/or reduce by a factor of 0.01 to 0.99:

“Number of strokes activated = factor x number of input pulses”

Examples

Factor

Pulse (sequential)

Stroke number (sequential)

 

Increase

1

1

1

 

 

2

1

2

 

 

 

 

 

 

 

25

1

25

 

 

99.99

1

99.99

 

 

 

 

 

 

 

1.50

1

1.5 (1 / 2)

 

 

1.25

1

1.25 (1 / 1 / 1 / 2)

 

 

 

 

 

 

Reduction

1

1

1

 

 

0.50

2

1

 

 

 

 

 

 

 

0.10

10

1

 

 

0.01

100

1

 

 

 

 

 

 

 

0.25

4

1

 

 

0.40

2.5 (3 / 2)

(1 / 1)

 

 

 

 

 

 

 

0.75

1.33 (2 / 1 / 1)

(1 / 1 / 1)

 

 

 

 

 

Explanation of increase

At a factor of

1

For every 1 pulse, 1 stroke is activated

 

At a factor of

2

For every 1 pulse, 2 strokes are activated

 

At a factor of

25

For every 1 pulse, 25 strokes are activated

Explanation of decrease

At a factor of 1

After 1 pulse, 1 stroke is activated

 

At a factor of 0.5

After 2 pulses, 1 stroke is activated

 

At a factor of 0.1

After 10 pulses, 1 stroke is activated

 

At a factor of 0.75

After 2 pulses, 1 stroke is activated,

 

 

 

then after 1 pulse, 1 stroke is activated,

 

 

 

then after 2 pulses, 1 stroke is activated etc.

Page 48

ProMinent®

Image 48
Contents Operating Instructions Control elements and key functions Control elements overviewOperating-/Settings Diagram Continuous DisplayPrevious Analog ActivatedfunctionImprint Dulcodes UV-Desinfektionsanlage ImprintDulcodes UV-Desinfektionsanlage Table of contents Table of contents Dulcodes UV-Desinfektionsanlage Identcode ordering system B a G m a B a s i c Ty p e S 2 B aIdentcode ordering system Dulcodes UV-Desinfektionsanlage ProMinent Dulcodes UV-Desinfektionsanlage Safety devices General notesDulcodes UV-Desinfektionsanlage Product description S2Ba/S2Ca Identification of pump typeDesign/Functional description Functional description, drive Stroke movement 75 % 30 %Metering capacity diagram HM50Hz MeteringcapacitydiagramS2BaS2CaHM Functional description, delivery unit Integrated overflow valve with bleeder function TaskDesign and functional description refer to Fig. No Product description S2Ba/S2Ca Diaphragm rupture sensor Use for intended purpose/Use unintended purposeFunction Design and function description see Fig3162-4 Pvdf Ptfe Technical data Technical data Sigma Capacity dataTechnical data S2Ca Temperature specificationsAccuracy Dimensions Sigma/ 2 mm Dimension sheet Sigma/ 2 with stroke adjustment motorModel Connector Stroke adjuster drive mechanism Motor dataStroke actuator drive mechanism Electrical data, stroke sensor ÒSigmaÓInput voltage Mains frequency Power consumption Electrical data, pacing relay ÒSigmaÓSound intensity level Relay inputStart-up/Maintenance MaintenanceStart-up Replacement of wearing parts Maintenance intervalsGuideline on Valve Installation Features of the S2Ca metering pumps Function description, motorsFunction description, controller ÒFloat switchÓ function Optional Òfault-indicating relayÓ or Òpower relayÓÒFault indicating and pacing relayÓ option LED indicator Operating indicator greenSockets, symbols and wiring diagram Hierarchy of operating modes, functions and fault statusesRelay type Power relay Wiring diagram Technical data, external contact Controller type 0 see identity codeController type 1 see identity code Block circuit diagram S2Ca InputsPump, Inside OutputsCircuit examples universal signal cable By customer CableRetrofitting relays Not in Profibus version Delivery rangeControl elements Settings SetCheck adjustable values Change to settings modeSelect operating mode Mode menu Settings for operating mode SET menu Settings for ÒmanualÓ operating modeSettings for ÒanalogueÓ operating mode Analg menu Set Straight lineSettings for ÒcontactÓ operating mode Contct menu Lower/upper bandLower band Upper band Alkali pump Acid pump Lower bandSet Settings for ÒbatchÓ operating mode Batch menu ÒMemoryÓ extension functionSettings for programmable functions SET menu Settings for ÒcalibrationÓ function Calib menuSettings for Òauxiliary frequencyÓ function AUX menu Settings for the ÒflowÓ function Flow menuSetting code Code menu Cancel total stroke number or total litres Clear windowOperating Manual operationTroubleshooting Remote controlError Messages Decommissioning and disposal Spare parts and accessories ProMinent 1011036For pumps without Ex protection For pumps with Ex protection Valve assy DN 15/PVT* Order No 6105-1040100-03 Order No Retrofit kit double diaphragm S2Ba/S2Ca Stroke actuator wiring diagram Wiring diagram for stroke length adjuster