RPC SERIES OWNER’S MANUAL

RPC SERIES QUICK START (RPC-2 MD01 AND RPC-2 RDR)

________________________________________________________________________________

Controlling Receptacles To set or change the status of the receptacles, enter one of the following commands: ON n, OFF n, REBOOT n, where “n” is the outlet number you want to command. Entering an outlet number of “0” sends the command to all outlets. Reboot only works on outlets which are in the “ON” condition.

CONFIGURATION

Type “CONFIG” from the RPC>prompt.

 

The following menu appears:

 

RPC >CONFIG

 

1) . . . Change Password

 

2) . . . Change Outlet Name

 

Enter Request:

Change Password

Default password is <cr>. The maximum

 

field length is 8 alphanumeric characters.

 

The password feature is case sensitive.

Change Outlet Name

Default Outlet Names are Outlet 1, Outlet

 

2, … The maximum field length is 10

 

alphanumeric characters.

7

Image 14
Contents RPC-2 RDR RPC-3 RPC-3A RPC-5 BayTech Manual Publication #U140E125-03 JulyPage Page Page Page ADD User Delete User Change Password Vii 230 VAC, 50/60 Hz, 10 Amp Introduction to the Remote Power Control Switch RPC115 VAC, 50/60 Hz, 15 Amp Operation RPC Series Quick StartRPC-2 and RPC-2A Quick Start Or for the RPC-2A RPC Series Quick Start RPC-2 and RPC-2A RPC-2 MD01 and RPC-2 RDR Quick Start RPC-2 RDROperation Configuration Change PasswordNetwork port Remote access usingRPC-3, RPC-3A and RPC-5 Quick Start Manage Users Deletion of the admin user is prohibitedOutlet Control Change Outlet Change Password Default password is cr disabled8. Default is no outlets selected ListLogout Reset UnitUnit Status Unpacking InstallationPreparing the Installation Site Power Circuit Breaker Power ON/OFF StatePower UP Sequence Cabling RJ-45 Cables and AdaptersRPC RJ-45 control port uses the following signals Computer/Terminal Adapter Crossed 8-pin Modular Cable Detailed Operation Configuration RPC-2 and RPC-2ARPC’s main menu allows the user to Controlling Receptacles Detailed Operation and Configuration Select #1, Change Password, and press Enter New Password To return to the RPC prompt, press any Key at the Enter Request promptSwitch, the RPC responds with the option to From the configuration menu, select #3Enable/Disable Confirmation Change the current status. Default isRPC-2 MD01 and RPC-2 RDR Local AccessUsing the EIA-232 Serial ConnectionRemote Access Using Modem Connections RPC’s main menu allows you to Responding Y for yes turns On Outlet If prompted, enter password. The following main menu appears Outlet RPC Config RPC Outlet Enter Request RPC-3 and RPC-3A and RPC-5 Using Network Using EIA-232Remote Access Port ConnectionOperation Detailed Operation and Configuration Password. When a successful username If this is not an initial setup and usernameAnd/or password have been enabled, you And/or password has been entered, the mainTo On in the status menu Responding Y for yes turns On OutletObserve the status of Outlet 3 has changed Show in the User Management Menu, along If this is not an initial setup and optionalOutlet users have been added, they too will With the option to delete usersAdd User Delete userDefault password is cr Enter new password = 8 characters To change outlet access, enter numbers of outlets. If Select #3, Configuration. The following Configuration can be performed byAdmin user only via the serial port or Network port. From the RPC Main MenuDefault Subnet Mask is 0.0.0.0. If you fail Default Unit ID is RPC-3 AccessOutlet Operation Configuration Menu Disable Outlet Status Display? Y/N Outlet 1, Outlet 2, Outlet 3 . . . Outlet Unique set-up.Default outlet names areName Outlets To return to the configuration menu, press any key RPC unit system status, network Status. In the event of problems withUnit status provides vital information about Interface, logged user status, and outletSystem Status Enter the number of the session to terminate RPC responds Reset the unit to load new configuration ChangesStatus Technical Support Outlet OUTLET3 Equipment SetupRPC Series Unit Model RPC Series Unit Serial Number OutletInstructions for Repackaging and Shipping Call BayTech to get a Return Authorization NumberREPACKAGING, Shipping and Returning to the Factory FCC Radio Frequency Interface Statement FCC Requirements for the RPC-2 MD01 and RDRFCC Radio Frequency Interface Statement Specifications Appendix aSpecifications Robotic Modems Modem Command SummaryAppendix B Save modem’s configuration in non-volatile memory Rockwell Chip SET ModemsIndication Interpretation Diagnostic LED IndicationsAppendix C Appendix D RPC Troubleshooting GuideProblem Symptom Cause Solution Appendix D RPC Troubleshooting Guide Cont’ Appendix D RPC Troubleshooting Guide Cont’ Appendix E- Drawings RPC-2RPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC3/3A/5 Ethernet Board RPC-5 Index Shipping