HP R-2 MD01, R-2A, R-3A, R-2 RDR manual Detailed Operation and Configuration

Page 46

RPC SERIES OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

________________________________________________________________________________

In the RPC Series’s main menu, #1 “Outlet Control” and #4 “Unit Status” allow the user to monitor and control the equipment attached to each of the RPC’s eight receptacles. Selection #3 puts the user into the configuration menu for setting network parameters, programming user login access, and outlet configuration. Selection #2 allows the admin user to manage optional users. Selection #5 resets the unit. A unit reset is required for some changes to take effect.

There are eight red LED’s on the front of the RPC unit. There is a corresponding red LED for each of the RPC’s eight receptacles. If any or all of the LEDs are illuminated, the corresponding receptacle(s) are turned "ON," and consequently, attached equipment is receiving power. If any one (or all) of the LED’s are not illuminated, the corresponding receptacle(s) are turned “OFF.”

Accessing Main Menu Power on the RPC unit. The following main

menu appears:

RPC-3 Telnet Host

Revision F 3.03, (C) 1998

Bay Technical Associates

Unit ID: RPC3

RPC-3 Menu:

1). . . Outlet Control

2). . . Manage Users

3). . . Configuration

4). . . Unit Status

5). . . Reset Unit

6). . . Logout

Enter Selection:

39

Image 46
Contents RPC-2 RDR RPC-3 RPC-3A RPC-5 BayTech Manual Publication #U140E125-03 JulyPage Page Page Page ADD User Delete User Change Password Vii 115 VAC, 50/60 Hz, 15 Amp Introduction to the Remote Power Control Switch RPC230 VAC, 50/60 Hz, 10 Amp RPC-2 and RPC-2A Quick Start RPC Series Quick StartOperation Or for the RPC-2A RPC Series Quick Start RPC-2 and RPC-2A RPC-2 MD01 and RPC-2 RDR Quick Start RPC-2 RDROperation Configuration Change PasswordRPC-3, RPC-3A and RPC-5 Quick Start Remote access usingNetwork port Outlet Control Deletion of the admin user is prohibitedManage Users Change Outlet Change Password Default password is cr disabled8. Default is no outlets selected ListUnit Status Reset UnitLogout Preparing the Installation Site InstallationUnpacking Power Power UP Sequence Power ON/OFF StateCircuit Breaker Cabling RJ-45 Cables and AdaptersRPC RJ-45 control port uses the following signals Computer/Terminal Adapter Crossed 8-pin Modular Cable Detailed Operation Configuration RPC-2 and RPC-2ARPC’s main menu allows the user to Controlling Receptacles Detailed Operation and Configuration Select #1, Change Password, and press Enter New Password To return to the RPC prompt, press any Key at the Enter Request promptSwitch, the RPC responds with the option to From the configuration menu, select #3Enable/Disable Confirmation Change the current status. Default isRPC-2 MD01 and RPC-2 RDR Local AccessUsing the EIA-232 Serial ConnectionRemote Access Using Modem Connections RPC’s main menu allows you to Responding Y for yes turns On Outlet If prompted, enter password. The following main menu appears Outlet RPC Config RPC Outlet Enter Request RPC-3 and RPC-3A and RPC-5 Using Network Using EIA-232Remote Access Port ConnectionOperation Detailed Operation and Configuration Password. When a successful username If this is not an initial setup and usernameAnd/or password have been enabled, you And/or password has been entered, the mainObserve the status of Outlet 3 has changed Responding Y for yes turns On OutletTo On in the status menu Show in the User Management Menu, along If this is not an initial setup and optionalOutlet users have been added, they too will With the option to delete usersAdd User Delete userDefault password is cr Enter new password = 8 characters To change outlet access, enter numbers of outlets. If Select #3, Configuration. The following Configuration can be performed byAdmin user only via the serial port or Network port. From the RPC Main MenuDefault Subnet Mask is 0.0.0.0. If you fail Default Unit ID is RPC-3 AccessOutlet Operation Configuration Menu Disable Outlet Status Display? Y/N Name Outlets Unique set-up.Default outlet names areOutlet 1, Outlet 2, Outlet 3 . . . Outlet To return to the configuration menu, press any key RPC unit system status, network Status. In the event of problems withUnit status provides vital information about Interface, logged user status, and outletSystem Status Enter the number of the session to terminate RPC responds Reset the unit to load new configuration ChangesStatus Technical Support Outlet OUTLET3 Equipment SetupRPC Series Unit Model RPC Series Unit Serial Number OutletREPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberInstructions for Repackaging and Shipping FCC Radio Frequency Interface Statement FCC Requirements for the RPC-2 MD01 and RDRFCC Radio Frequency Interface Statement Specifications Appendix aSpecifications Appendix B Modem Command SummaryRobotic Modems Save modem’s configuration in non-volatile memory Rockwell Chip SET ModemsAppendix C Diagnostic LED IndicationsIndication Interpretation Problem Symptom Cause Solution RPC Troubleshooting GuideAppendix D Appendix D RPC Troubleshooting Guide Cont’ Appendix D RPC Troubleshooting Guide Cont’ Appendix E- Drawings RPC-2RPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC3/3A/5 Ethernet Board RPC-5 Index Shipping