HP R-2 RDR, R-2A, R-2 MD01, R-3A RPC Series Quick Start, RPC-2 and RPC-2A Quick Start, Operation

Page 9

RPC SERIES OWNER’S MANUAL

RPC SERIES QUICK START (RPC-2 AND RPC-2A)

________________________________________________________________________________

RPC SERIES QUICK START

“Quick Start” is designed for users familiar with BayTech products who need a fast setup and familiarization. Detailed information on each of the functions and steps of operation and configuration may be found beginning at pages 19, 27, and 36 of this manual. Each “Quick Start” will discuss similar models.

RPC-2 AND RPC-2A QUICK START

EIA-232 serial

Using the 9FRJ45PC-1 adapter and the

connection

RJ08X007 cable, connect the serial port of

 

your computer to the RJ-45 port labeled

 

“EIA-232.”

 

Load serial port communications software.

 

Set serial communications parameters to

 

9600 bps, 8 data bits, 1 stop bit, and no

 

parity.

OPERATION

 

Accessing Main Menu

Power on the RPC unit. The following status

 

menu appears:

RPC-2 Series

(C)1997 by BayTech

F2.07

Circuit Breaker : On

1) . . . OUTLET 1

: Off

2) . . . OUTLET 2

: Off

3) . . . OUTLET 3

: Off

4) . . . OUTLET 4

: Off

5) . . . OUTLET 5

: Off

6) . . . OUTLET 6

: Off

RPC >

 

2

Image 9
Contents BayTech Manual Publication #U140E125-03 July RPC-2 RDR RPC-3 RPC-3A RPC-5Page Page Page Page ADD User Delete User Change Password Vii Introduction to the Remote Power Control Switch RPC 115 VAC, 50/60 Hz, 15 Amp230 VAC, 50/60 Hz, 10 Amp RPC Series Quick Start RPC-2 and RPC-2A Quick StartOperation Or for the RPC-2A RPC Series Quick Start RPC-2 and RPC-2A RPC-2 RDR RPC-2 MD01 and RPC-2 RDR Quick StartOperation Change Password ConfigurationRemote access using RPC-3, RPC-3A and RPC-5 Quick StartNetwork port Deletion of the admin user is prohibited Outlet ControlManage Users 8. Default is no outlets selected Change Password Default password is cr disabledChange Outlet ListReset Unit Unit StatusLogout Installation Preparing the Installation SiteUnpacking Power Power ON/OFF State Power UP SequenceCircuit Breaker RJ-45 Cables and Adapters CablingRPC RJ-45 control port uses the following signals Computer/Terminal Adapter Crossed 8-pin Modular Cable RPC-2 and RPC-2A Detailed Operation ConfigurationRPC’s main menu allows the user to Controlling Receptacles Detailed Operation and Configuration Select #1, Change Password, and press Enter New Password Key at the Enter Request prompt To return to the RPC prompt, press anyEnable/Disable Confirmation From the configuration menu, select #3Switch, the RPC responds with the option to Change the current status. Default isUsing the EIA-232 Local AccessRPC-2 MD01 and RPC-2 RDR Serial ConnectionRemote Access Using Modem Connections RPC’s main menu allows you to Responding Y for yes turns On Outlet If prompted, enter password. The following main menu appears Outlet RPC Config RPC Outlet Enter Request RPC-3 and RPC-3A and RPC-5 Remote Access Using EIA-232Using Network Port ConnectionOperation Detailed Operation and Configuration And/or password have been enabled, you If this is not an initial setup and usernamePassword. When a successful username And/or password has been entered, the mainResponding Y for yes turns On Outlet Observe the status of Outlet 3 has changedTo On in the status menu Outlet users have been added, they too will If this is not an initial setup and optionalShow in the User Management Menu, along With the option to delete usersDelete user Add UserDefault password is cr Enter new password = 8 characters To change outlet access, enter numbers of outlets. If Admin user only via the serial port or Configuration can be performed bySelect #3, Configuration. The following Network port. From the RPC Main MenuDefault Subnet Mask is 0.0.0.0. If you fail Access Default Unit ID is RPC-3Outlet Operation Configuration Menu Disable Outlet Status Display? Y/N Unique set-up.Default outlet names are Name OutletsOutlet 1, Outlet 2, Outlet 3 . . . Outlet To return to the configuration menu, press any key Unit status provides vital information about Status. In the event of problems withRPC unit system status, network Interface, logged user status, and outletSystem Status Enter the number of the session to terminate RPC responds Changes Reset the unit to load new configurationStatus Technical Support RPC Series Unit Model RPC Series Unit Serial Number Equipment SetupOutlet OUTLET3 OutletCall BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryInstructions for Repackaging and Shipping FCC Requirements for the RPC-2 MD01 and RDR FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Appendix a SpecificationsSpecifications Modem Command Summary Appendix BRobotic Modems Rockwell Chip SET Modems Save modem’s configuration in non-volatile memoryDiagnostic LED Indications Appendix CIndication Interpretation RPC Troubleshooting Guide Problem Symptom Cause SolutionAppendix D Appendix D RPC Troubleshooting Guide Cont’ Appendix D RPC Troubleshooting Guide Cont’ RPC-2 Appendix E- DrawingsRPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC3/3A/5 Ethernet Board RPC-5 Index Shipping