HP R-2 MD01, R-2A, R-3A Outlet Control, Manage Users, Deletion of the admin user is prohibited

Page 16

RPC SERIES OWNER’S MANUAL

RPC SERIES QUICK START (RPC-3, RPC-3A, AND RPC-5)

________________________________________________________________________________

RPC-3 Telnet Host

Revision F 3.03, (C) 1998

Bay Technical Associates

Unit ID: RPC3

 

RPC-3 Menu:

 

1) . . .

Outlet Control

 

2) . . .

Manage Users

 

3) . . .

Configuration

 

4) . . .

Unit Status

 

5) . . .

Reset Unit

 

6) . . .

Logout

 

Enter Selection:

 

If the main menu fails to appear, ensure the

 

correct cables and adapters are being used

 

and that they are connected properly. Also,

 

verify the serial communication

 

parameters are correctly configured.

Outlet Control

From the RPC> prompt, enter one of the

 

following commands: ON n, OFF n,

 

REBOOT where “n” is the outlet number

 

you want to command. Entering an outlet

 

number of “0” sends the command to all

 

outlets. Type “MENU” to return to the

 

main menu. . Reboot only works on outlets

 

which are in the “ON” condition.

Manage Users

New users (a maximum of 4 for the RPC-5

 

or 8 for the RPC-3/3A) may be added or

deleted using this menu. Any time there is more than 1 user besides the admin, a “Delete user” function will appear. Any time the maximum number of users is reached, the “Add user” function will disappear.

Deletion of the admin user is prohibited.

9

Image 16
Contents RPC-2 RDR RPC-3 RPC-3A RPC-5 BayTech Manual Publication #U140E125-03 JulyPage Page Page Page ADD User Delete User Change Password Vii 115 VAC, 50/60 Hz, 15 Amp Introduction to the Remote Power Control Switch RPC230 VAC, 50/60 Hz, 10 Amp RPC-2 and RPC-2A Quick Start RPC Series Quick StartOperation Or for the RPC-2A RPC Series Quick Start RPC-2 and RPC-2A RPC-2 MD01 and RPC-2 RDR Quick Start RPC-2 RDR Operation Configuration Change PasswordRPC-3, RPC-3A and RPC-5 Quick Start Remote access usingNetwork port Outlet Control Deletion of the admin user is prohibitedManage Users Change Password Default password is cr disabled 8. Default is no outlets selectedChange Outlet ListUnit Status Reset UnitLogout Preparing the Installation Site InstallationUnpacking Power Power UP Sequence Power ON/OFF StateCircuit Breaker Cabling RJ-45 Cables and AdaptersRPC RJ-45 control port uses the following signals Computer/Terminal Adapter Crossed 8-pin Modular Cable Detailed Operation Configuration RPC-2 and RPC-2ARPC’s main menu allows the user to Controlling Receptacles Detailed Operation and Configuration Select #1, Change Password, and press Enter New Password To return to the RPC prompt, press any Key at the Enter Request promptFrom the configuration menu, select #3 Enable/Disable ConfirmationSwitch, the RPC responds with the option to Change the current status. Default isLocal Access Using the EIA-232RPC-2 MD01 and RPC-2 RDR Serial ConnectionRemote Access Using Modem Connections RPC’s main menu allows you to Responding Y for yes turns On Outlet If prompted, enter password. The following main menu appears Outlet RPC Config RPC Outlet Enter Request RPC-3 and RPC-3A and RPC-5 Using EIA-232 Remote AccessUsing Network Port ConnectionOperation Detailed Operation and Configuration If this is not an initial setup and username And/or password have been enabled, youPassword. When a successful username And/or password has been entered, the mainObserve the status of Outlet 3 has changed Responding Y for yes turns On OutletTo On in the status menu If this is not an initial setup and optional Outlet users have been added, they too willShow in the User Management Menu, along With the option to delete usersAdd User Delete userDefault password is cr Enter new password = 8 characters To change outlet access, enter numbers of outlets. If Configuration can be performed by Admin user only via the serial port orSelect #3, Configuration. The following Network port. From the RPC Main MenuDefault Subnet Mask is 0.0.0.0. If you fail Default Unit ID is RPC-3 AccessOutlet Operation Configuration Menu Disable Outlet Status Display? Y/N Name Outlets Unique set-up.Default outlet names areOutlet 1, Outlet 2, Outlet 3 . . . Outlet To return to the configuration menu, press any key Status. In the event of problems with Unit status provides vital information aboutRPC unit system status, network Interface, logged user status, and outletSystem Status Enter the number of the session to terminate RPC responds Reset the unit to load new configuration ChangesStatus Technical Support Equipment Setup RPC Series Unit Model RPC Series Unit Serial NumberOutlet OUTLET3 OutletREPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberInstructions for Repackaging and Shipping FCC Radio Frequency Interface Statement FCC Requirements for the RPC-2 MD01 and RDRFCC Radio Frequency Interface Statement Specifications Appendix aSpecifications Appendix B Modem Command SummaryRobotic Modems Save modem’s configuration in non-volatile memory Rockwell Chip SET ModemsAppendix C Diagnostic LED IndicationsIndication Interpretation Problem Symptom Cause Solution RPC Troubleshooting GuideAppendix D Appendix D RPC Troubleshooting Guide Cont’ Appendix D RPC Troubleshooting Guide Cont’ Appendix E- Drawings RPC-2RPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC3/3A/5 Ethernet Board RPC-5 Index Shipping