HP R-3A, R-2 If this is not an initial setup and username, And/or password have been enabled, you

Page 47

RPC SERIES OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

________________________________________________________________________________

If the main menu fails to appear, ensure the correct cables and adapters are being used and they are properly connected. Also, verify the serial communication parameters are correctly configured.

 

If this is not an initial setup and username

 

and/or password have been enabled, you

 

will be prompted to enter a username and/or

 

password. When a successful username

 

and/or password has been entered, the main

 

menu (above) appears.

 

 

Outlet Control

To set or change the status of receptacles,

 

select #1 “Outlet Control” from the main

 

menu. The following status menu appears:

 

Available RPC3 Outlets

 

 

 

For command summary, enter HELP

 

 

Circuit Breaker : On (RPC-3/3A ONLY *)

(RPC-5 only*)

 

 

 

 

 

 

Selection

Outlet

Outlet

Power

CB

 

Number

Name

Number

Status

Status

 

1

OUTLET 1

1

Off

On

 

2

OUTLET 2

2

Off

Off

 

3

OUTLET 3

3

Off

Off

 

4

OUTLET 4

4

Off

Off

 

5

OUTLET 5

5

Off

 

 

6

OUTLET 6

6

Off

 

 

7

OUTLET 7

7

Off

 

 

8

OUTLET 8

8

Off

 

RPC >

NOTE: * These menu items are displayed for the designated units only. The printing in parentheses does not appear on the screen.

NOTE: CB status for the RPC-5 will show “On” when a power cord is attached to the “In” receptacle of a specific port and power is available to the “Out” receptacle.

40

Image 47
Contents BayTech Manual Publication #U140E125-03 July RPC-2 RDR RPC-3 RPC-3A RPC-5Page Page Page Page ADD User Delete User Change Password Vii 230 VAC, 50/60 Hz, 10 Amp Introduction to the Remote Power Control Switch RPC115 VAC, 50/60 Hz, 15 Amp Operation RPC Series Quick StartRPC-2 and RPC-2A Quick Start Or for the RPC-2A RPC Series Quick Start RPC-2 and RPC-2A RPC-2 RDR RPC-2 MD01 and RPC-2 RDR Quick StartOperation Change Password ConfigurationNetwork port Remote access usingRPC-3, RPC-3A and RPC-5 Quick Start Manage Users Deletion of the admin user is prohibitedOutlet Control List Change Password Default password is cr disabled8. Default is no outlets selected Change OutletLogout Reset UnitUnit Status Unpacking InstallationPreparing the Installation Site Power Circuit Breaker Power ON/OFF StatePower UP Sequence RJ-45 Cables and Adapters CablingRPC RJ-45 control port uses the following signals Computer/Terminal Adapter Crossed 8-pin Modular Cable RPC-2 and RPC-2A Detailed Operation ConfigurationRPC’s main menu allows the user to Controlling Receptacles Detailed Operation and Configuration Select #1, Change Password, and press Enter New Password Key at the Enter Request prompt To return to the RPC prompt, press anyChange the current status. Default is From the configuration menu, select #3Enable/Disable Confirmation Switch, the RPC responds with the option toSerial Connection Local AccessUsing the EIA-232 RPC-2 MD01 and RPC-2 RDRRemote Access Using Modem Connections RPC’s main menu allows you to Responding Y for yes turns On Outlet If prompted, enter password. The following main menu appears Outlet RPC Config RPC Outlet Enter Request RPC-3 and RPC-3A and RPC-5 Port Connection Using EIA-232Remote Access Using NetworkOperation Detailed Operation and Configuration And/or password has been entered, the main If this is not an initial setup and usernameAnd/or password have been enabled, you Password. When a successful usernameTo On in the status menu Responding Y for yes turns On OutletObserve the status of Outlet 3 has changed With the option to delete users If this is not an initial setup and optionalOutlet users have been added, they too will Show in the User Management Menu, alongDelete user Add UserDefault password is cr Enter new password = 8 characters To change outlet access, enter numbers of outlets. If Network port. From the RPC Main Menu Configuration can be performed byAdmin user only via the serial port or Select #3, Configuration. The followingDefault Subnet Mask is 0.0.0.0. If you fail Access Default Unit ID is RPC-3Outlet Operation Configuration Menu Disable Outlet Status Display? Y/N Outlet 1, Outlet 2, Outlet 3 . . . Outlet Unique set-up.Default outlet names areName Outlets To return to the configuration menu, press any key Interface, logged user status, and outlet Status. In the event of problems withUnit status provides vital information about RPC unit system status, networkSystem Status Enter the number of the session to terminate RPC responds Changes Reset the unit to load new configurationStatus Technical Support Outlet Equipment SetupRPC Series Unit Model RPC Series Unit Serial Number Outlet OUTLET3Instructions for Repackaging and Shipping Call BayTech to get a Return Authorization NumberREPACKAGING, Shipping and Returning to the Factory FCC Requirements for the RPC-2 MD01 and RDR FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Appendix a SpecificationsSpecifications Robotic Modems Modem Command SummaryAppendix B Rockwell Chip SET Modems Save modem’s configuration in non-volatile memoryIndication Interpretation Diagnostic LED IndicationsAppendix C Appendix D RPC Troubleshooting GuideProblem Symptom Cause Solution Appendix D RPC Troubleshooting Guide Cont’ Appendix D RPC Troubleshooting Guide Cont’ RPC-2 Appendix E- DrawingsRPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC3/3A/5 Ethernet Board RPC-5 Index Shipping